Skip to main content

Part of the book series: Lecture Notes in Networks and Systems ((LNNS,volume 85))

Included in the following conference series:

  • 445 Accesses

Abstract

The paper presents a study concerning mechanical behavior of contact lenses. There were considered different materials for contact lenses like: conventional Hydrogel, Silicone-Hydrogel with different lens powers. The lenses were tested using a vertical test stand from Hans Schmidt, equipped with Imada force transducer. The lenses were “pushed” on a plane surface using a certain transducer accessory. Also, a FEM simulation of contact lenses was developed in Solidworks in order to study the lenses behavior for different peripheral curves, widths, junctions and lens diameter. There were considered the lens deflection, lens deformation and lens stresses. The diameter of a soft contact lens should be a specific amount larger than the actual corneal diameter. One conclusion of this study is: contact lens diameter may be a better predictor than base curve is of lens behaviour on eye.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Wichterle, O., Lim, D.: Hydrophilic gels for biological use. Nature 185, 117–118 (1960)

    Article  Google Scholar 

  2. Vu, L.T., Chao-Chang, A.C., Chia-Cheng, L., Chia-Wei, Y.: Compensating additional optical power in the central zone of a multifocal contact lens forminimization of the shrinkage error of the shell mold in the injection molding process. Appl. Opt. 57(12), 2981–2991 (2018)

    Article  Google Scholar 

  3. Davis, R.L.: Determining multifocal parameters for a better fit. Rev. Optom., August 2016

    Google Scholar 

  4. Becherer, P.D., Davis, R.L., Kempf, J.A.: A personalized contact lens prescription. Contact lens spectrum, January 2007

    Google Scholar 

  5. Becherer, P.D.: Customizing with care. Optometric Office, September 2013

    Google Scholar 

  6. Young, G., Hall, L., Sulley, A., Osborn-Lorenz, K., Wolffsohn, J.S.: Inter-relationship of soft contact lens diameter, base curve radius, and fit. Optom. Vis. Sci. 94(4), 458–465 (2017)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dana Rizescu .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Rizescu, D., Bogatu, L., Rizescu, C.I. (2020). Study the Mechanical Behavior of Contact Lenses. In: Gheorghe, G. (eds) Proceedings of the International Conference of Mechatronics and Cyber-MixMechatronics – 2019. ICOMECYME 2019. Lecture Notes in Networks and Systems, vol 85. Springer, Cham. https://doi.org/10.1007/978-3-030-26991-3_3

Download citation

Publish with us

Policies and ethics