Abstract
The blood flow dynamics in microcirculation depends strongly on the motion, deformation and interaction of red blood cells (RBCs) within the microves-sel. We present confocal micro-PTV measurements on the motion of individual RBCs through a circular polydimethysiloxane (PDMS) microchannel. The RBC radial displacement and dispersion calculated from these measurements show that the RBC paths are strongly dependent on the both Hct and plasma layer. In order to obtain more detailed information of the non-Newtonian property of blood a novel computational scheme is also described. The simulated flow dynamics were in good agreement with the Casson flow model and in vivo observations. In the near future by comparing both results we hope to clarify a variety of complex phenomena occurring at the microscale level.
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Abramoff M., Magelhaes P., Ram S. (2004) Image Processing with Image Journal of Biophotonics International 11: 36–42.
Caro C., Pedley, T., Schroter R., Seed W. (1978) The mechanics of the circulation. Oxford, Oxford University Press.
Chien S., Usami S., Skalak R. (1984) Blood flow in small tubes In: Handbook of physiology — the cardiovascular system IV, Microcirculation, Part I. Bethesda MD, American Physiological Society, pp 217–249.
Cloutier G., Qin Z., Durand L.G., Teh B.G. (1996) Power Doppler ultrasound evaluation of the shear rate and shear stress Dependences of red blood cell aggregation. IEEE Transactions on Biomedical Engineering 43: 441–450.
Fahraeus R., Lindqvist T. (1931) The viscosity of the blood in narrow capillary tubes. American Journal of Physiology 96: 562–568.
Goldsmith H. (1971) Red cell motions and wall interactions in tube flow. Federation Proceedings 30: 1578–1588.
Goldsmith H., Marlow J. (1979) Flow behavior of erythrocytes. II. Particles motions in concentrated suspensions of ghost cells. Journal of Colloid and Interface Science 71: 383–407.
Goldsmith H., Turitto V. (1986) Rheological aspects of thrombosis and haemostasis: basic principles and applications. ICTH-Report-Subcommittee on Rheology of the International Committee on Thrombosis and Haemostasis. Thrombosis and Haemostasis 55: 415–435.
Ishikawa T., Pedley T. (2007) Diffusion of swimming model micro-organisms in a semi-dilute suspensions. Journal of Fluid Mechanics 588: 437–462.
Lima R., Ishikawa T., Imai, Y., Takeda, M., Wada, S., Yamaguchi, T. (2008a) “Measurement of individual red blood cell motions under high hematocrit conditions using a confocal micro-PTV system” (under revision to Annals of Biomedical Engineering).
Lima R., Ishikawa T., Imai, Y., Takeda, M., Wada, S., Yamaguchi, T. (2008) Radial dispersion of red blood cells in blood flowing through glass capillaries: role of hematocrit and geometry. Journal of Biomechanics 41: 2188–2196.
Lima R. (2007) Analysis of the blood flow behavior through microchannels by a confocal micro-PIV/PTV system. Ph.D. thesis, Tohoku University, Japan.
Lima, R., Wada, S., Takeda, M., Tsubota, K., Yamaguchi, T. (2007) In vitro confocal micro-PIV measurements of blood flow in a square microchannel: the effect of the haematocrit on instantaneous velocity profiles. Journal of Biomechanics 40: 2752–2757.
Lima, R., Wada, S., Tanaka, S., Takeda, M., Ishikawa, T., Tsubota, K., Imai, Y., Yamaguchi, T. (2008) In vitro blood flow in a rectangular PDMS microchannel: experimental observations using a confocal micro-PIV system. Biomedical Microdevices 10: 153–167.
Lima, R., Wada, S., Tsubota, K., Yamaguchi, T. (2006) Confocal micro-PIV measurements of three dimensional profiles of cell suspension flow in a square microchannel. Measurement Science and Technology 17: 797–808.
Meijering E., Smal I., Danuser G. (2006) Tracking in molecular bioimaging. IEEE Signal Processing Magazine 23: 46–53.
Oka S. (1984) Biorehology. Shokabo, Tokyo.
Park J., Choi C., Kihm K. (2004) Optically sliced micro-PIV using confocal laser scanning microscopy (CLSM). Experiments in Fluids 37: 105–119.
Schmid-Schonbein, H., Wells, R. (1969) Fluid drop-like transition of erythrocytes under shear. Science 165: 288–291.
Shiga T., Maeda N., Suda T., Kon K., Sekiya M., Oka S. (1979) Rheological and kinetic dysfunctions of the cholesterol-loaded, human erythrocytes. Biorheology 16: 363–369.
Tanaami T., Otsuki S., Tomosada N., Kosugi Y., Shimizu M., Ishida H. (2002) High-speed 1-frame/ms scanning confocal microscope with a microlens and Nipkow disks. Applied Optics 41: 4704–4708.
Wada S., Kobayashi R. (2003) Numerical simulation of various shape changes of a swollen red blood cell by decrease of its volume. Transactions of the Japan Society of Mechanical Engineers 69A: 14–21 (in Japanese).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer Science +Business Media B.V.
About this chapter
Cite this chapter
Lima, R., Nakamura, M., Omori, T., Ishikawa, T., Wada, S., Yamaguchi, T. (2009). Microscale Flow Dynamics of Red Blood Cells in Microchannels: An Experimental and Numerical Analysis. In: Tavares, J.M.R.S., Jorge, R.M.N. (eds) Advances in Computational Vision and Medical Image Processing. Computational Methods in Applied Sciences, vol 13. Springer, Dordrecht. https://doi.org/10.1007/978-1-4020-9086-8_12
Download citation
DOI: https://doi.org/10.1007/978-1-4020-9086-8_12
Publisher Name: Springer, Dordrecht
Print ISBN: 978-1-4020-9085-1
Online ISBN: 978-1-4020-9086-8
eBook Packages: Computer ScienceComputer Science (R0)