Abstract
With the advent of subsecond rotation combined with prospective electrocardiogram (ECG) triggering or retrospective ECG gating, conventional computed tomography (CT) with spiral capability and superior general image quality has challenged electron beam CT (EBCT) in the domain of cardiac imaging. The introduction of multislice CT scanning with the Siemens SOMATOM Volume Zoom with 4 simultaneously scanned slices, half-second rotation, and 250-ms maximum temporal resolution has recently opened new horizons for cardiac CT imaging. ECG-gated multislice spiral CT represents a leap in image quality of CT angiography (CTA) of the coronary arteries. The fast volume coverage allows scanning the heart with 1-mm slice collimation within a single breath-hold (10 cm in 25–30 s) for high-resolution imaging. Three-dimensional reconstruction with approx 1-mm slice width and submillimeter increment provide data of unique quality for visualization of the coronary arteries and of the arterial/venous grafts utilized for surgical revascularization. This chapter will be focused on the clinical background, the previous CT applications in this setting, and the recent results of multidetector-row CT (MDCT) evaluation of coronary artery bypass grafting (CABG).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Shumacker HB. The Evolution of Cardiac Surgery. Indiana University Press, Bloomington, IN: 1992.
Garrett HE, Dennis EW, DeBakey ME. Aortocoronary bypass with saphenous vein graft: seven-year follow-up. JAMA 1973;223:792–794.
Favaloro RG. Critical analysis of coronary artery bypass graft surgery: a 30-year journey. J Am Coll Cardiol 1998;31:1B–63B.
Campeau L, Enjalbert M, Lesperance J, et al. The relation of risk factors to the development of atherosclerosis in saphenous vein bypass grafts and the progression of disease in the native circulation: a study 10 years after aortocoronary bypass surgery. N Engl J Med 1984;311:1329–1332.
Bourassa MG. Fate of venous grafts: the past, the present and the future. J Am Coll Cardiol 1991;5:1081–1083.
Fitzgibbon GM, Kafka HP, Leach AJ, et al. Coronary bypass graft fate and patient outcome: angiographic follow-up of 5065 grafts related to survival and reoperation in 1388 patients during 25 years. J Am Coll Cardiol 1996;28:616–626.
Loop FD. Internal-thoracic-artery grafts: biologically better coronary arteries. N Engl J Med 1996;334:263–265.
Calafiore AM, Angelini GD, Bergsland J, et al. Minimally invasive coronary artery bypass grafting. Ann Thorac Surg 1996;62:1545–1548.
Brundage BH, Lipton MJ, Herfkens RJ, et al. Detection of patent bypass grafts by computed tomography: a preliminary report. Circulation 1980;61:826–831.
Ullyot DJ, Turley K, McKay CR, et al. Assessment of saphenous vein graft patency by contrast-enhanced computed tomography. J Thorac Cardiovasc Surg 1982;83:512–518.
Godwin JD, Califf RM, Korobkin M, et al. Clinical value of coronary bypass graft evaluation with CT. AJR Am J Roentgenol 1983;140:649–655.
Daniel WG, Dohring W, Stender HS, et al. Value and limitations of computed tomography in assessing aortocoronary bypass graft patency. Circulation 1983;67:983–987.
Tello R, Costello P, Ecker CP, et al. Spiral CT evaluation of coronary artery bypass graft patency. J Comput Assist Tomogr 1993;17:253–259.
Engelmann MG, von Smekal A, Knez A, et al. Accuracy of spiral computed tomography for identifying arterial and venous coronary graft patency. Am J Cardiol 1997;80:569–574.
Tello R, Hartnell GG, Costello P, et al. Coronary artery bypass graft flow: qualitative evaluation with cine single-detector row CT and comparison with findings at angiography. Radiology 2002;224:913–918.
Ha JW, Cho SY, Shim WH, et al. Noninvasive evaluation of coronary artery bypass graft patencyusing three-dimensional angiography obtained with contrast-enhanced electron beam CT. AJR Am J Roentgenol 1999;172:1055–1059.
Lu B, Dai RP, Jing BL, et al. Evaluation of coronary artery bypass graft patency using three-dimensional reconstruction and flow study on electron beam tomography. J Comput Assist Tomogr 2000;24:663–670.
von Smekal A, Lachat M, Wildermuth S, et al. Proximal anastomoses of aortocoronary bypasses. Evaluation with ECG-triggered single-slice computerized tomography. Radiologe 2000;40:130–135.
Ohtsuka T, Takamoto S, Endoh M, et al. Ultrafast computed tomography for minimally invasive coronary artery bypass grafting. J Thorac Cardiovasc Surg 1998;116:173–174.
Bauer EP, Bino MC, von Segesser LK, et al. Internal mammary artery anomalies. Thorac Cardiovasc Surg 1990;38:312–315.
De Santis M, Quagliarini F, Leonetti C, et al. MDSCT pre-operative evaluation of internal mammary arteries (IMAs) in patients candidate to minimally invasive coronary artery bypass grafting (MICABG) (abs). ECR, Vienna, Austria: 2003.
Weintraub WS, Jones EL, Craver JM, et al. Frequency of repeat coronary bypass or coronary angioplasty after coronary artery bypass surgery using saphenous venous grafts. Am J Cardiol 1994;73:103–112.
Loop FD, Lytle BW, Cosgrove DM, et al. Reoperation for coronary atherosclerosis: changing practice in 2509 consecutive patients. Ann Surg 1990;212:378–386.
Cameron A, Kemp HG Jr, Green GE. Reoperation for coronary artery disease: 10 years of clinical follow-up. Circulation 1988;78(Suppl I):I/158–I/162.
Yamaguchi A, Adachi H, Ino T, et al. Three-dimensional computed tomographic angiography as pre-operative evaluation of a patent internal thoracic artery graft. J Thorac Cardiovasc Surg 2000;120:811–812.
von Smekal A. The potential of cardio-computed tomography. Multislice CT: a practical guide. Proceedings of the 5th International Somatom CT User Conference. Zurich, June 2000.
Ohnesorge B, Flohr T, Becker CR, et al. Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 2000;217:564–571.
Nieman K, Oudkerk M, Rensing BJ, et al. Coronary angiography with multi-slice computed tomography. Lancet 2001;357(9256):599–603.
Ropers D, Ulzheimer S, Wenkel E, et al. Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction. Am J Cardiol 2001;88:792–795.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2005 Humana Press, Inc., Totowa, NJ
About this chapter
Cite this chapter
De Santis, M. (2005). CT Angiography for Assessment of Coronary Bypass Grafts. In: Schoepf, U.J. (eds) CT of the Heart. Contemporary Cardiology. Humana Press. https://doi.org/10.1385/1-59259-818-8:301
Download citation
DOI: https://doi.org/10.1385/1-59259-818-8:301
Publisher Name: Humana Press
Print ISBN: 978-1-58829-303-9
Online ISBN: 978-1-59259-818-2
eBook Packages: MedicineMedicine (R0)