Advertisement

Computer-aided planning of patellofemoral joint OA surgery: Developing physical models from patient MRI

  • Zohara A. Cohen
  • Denise M. McCarthy
  • Hrvoje Roglic
  • Jack H. Henry
  • William G. Rodkey
  • J. Richard Steadman
  • Van C. Mow
  • Gerard A. Ateshian
Conference paper
Part of the Lecture Notes in Computer Science book series (LNCS, volume 1496)

Abstract

Generally, the surgical procedures employed in the treatment of patellofemoral joint (PFJ) osteoarthritis (OA) aim, either explicitly or implicitly, to alter the biomechanics of the osteoarthritic joint (i.e., improve motion and load transmission characteristics). Because of the mechanical nature of some of these surgical objectives, they can be evaluated prior to and subsequent to surgery by using an appropriate patient-specific physical model of the patient’s PFJ, derived from 3D MRI data. This study describes the process by which such patient-specific physical models can be created using standard clinical imaging modalities.

Keywords

Articular Cartilage Patellofemoral Joint Surgical Simulation Multibody Model Lateral Retinacular Release 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 1.
    Aglietti P, Buzzi R, De Biase P, Giro NF: Surgical treatment of recurrent dislocation of the patella. Clin Orthop 308 (1994) 8–17Google Scholar
  2. 2.
    Altman R, Brandt K, Hochberg M, Moskowitz R: Design and conduct of clinical trials in patients with osteoarthritis: recommendations from a task force of the Osteoarthritis Research Society. Osteoarthritis Cartilage 4 (1996) 217–243CrossRefPubMedGoogle Scholar
  3. 3.
    An KN, Himeno S, Tsumura H, Kawai T, Caho E YS: Pressure distribution on articular surfaces: application to joint stability evaluation. J Biomech 23 (1990) 1013–1020CrossRefPubMedGoogle Scholar
  4. 4.
    Ateshian GA, Soslowsky LJ, and Mow VC: Quantitation of articular surface topography and cartilage thickness in knee joints using stereophotogrammetry. J Biomech 24 (1991) 761–776CrossRefPubMedGoogle Scholar
  5. 5.
    Ateshian GA, Kwak SD, Soslowsky LJ, Mow VC: A stereophotogrammetric method for determining in situ contact areas in diarthrodial joints, and a comparison with other methods. J Biomech 27 (1994) 111–124CrossRefPubMedGoogle Scholar
  6. 6.
    Blankevoort L, Kuiper JH, Huiskes R, Grootenboer HJ: Articular contact in a three-dimensional model of the knee. J Biomech 24 (1991) 1019–1031CrossRefPubMedGoogle Scholar
  7. 7.
    Burk DL Jr, Mears DC, Cooperstein LA, Herman GT, Udupa JK: Acetabular fractures: three-dimensional computed tomographic imaging and interactive surgical planning. J Comput Tomogr 10 (1986) 1–10CrossRefPubMedGoogle Scholar
  8. 8.
    Chao EYS, Lynch JD, Vanderploeg MJ: Simulation and animation of musculoskeletal joint system. J Biomech Eng 115 (1993) 562–568CrossRefPubMedGoogle Scholar
  9. 9.
    Chao EYS, Sim FH: Computer-aided preoperative planning in knee osteotomy. Iowa Orthop J 15 (1995) 4–18PubMedPubMedCentralGoogle Scholar
  10. 10.
    Cohen ZA, Kwak SD, Ateshian GA, Blankevoort L, Henry JH, Grelsamer RP, Mow VC: The effect of tibial tuberosity transfer on the patellofemoral joint: A 3-D simulation. Adv Bioeng, ASME, BED 33 (1996) 387–388Google Scholar
  11. 11.
    Cohen ZA, McCarthy DM, Ateshian GA, Kwak SD, Peterfy CG, Alderson P, Grelsamer RP, Henry JH, Mow VC: In vivo and in vitro knee joint cartilage topography, thickness, and contact areas from MRI. Trans Orthop Res Soc 22 (1997) 625Google Scholar
  12. 12.
    Cohen ZA, McCarthy DM, Ateshian GA, Kwak SD, Peterfy CG, Alderson P, Grelsamer RP, Henry JH, Mow VC: Knee joint topography and contact areas: validation of measurements from MRI. Proc Bioeng, ASME, BED 35 (1997) 45–46Google Scholar
  13. 13.
    Cohen ZA, McCarthy DM, Kwak SD, Legrand P, Fogarasi F, Ciaccio EJ, Ateshian GA: Knee cartilage topography, thickness, and contact areas from MRI: In vitro calibration and in vivo measurements. Osteoarthritis Cart (in press)Google Scholar
  14. 14.
    Delp SL, Loan JP, Hoy MG, Zajac FE, Topp EL, Rosen JM: An interactive, graphics-based model of the lower extremity to study orthopaedic surgical procedures. IEEE Trans Biomed Eng 37 (1990) 757–767CrossRefPubMedGoogle Scholar
  15. 15.
    Delp SL, Statler K, Carroll NC: Preserving plantar flexion strength after surgical treatment for contracture of the triceps surae: a computer simulation study. J Orthop Res 13 (1994) 96–104CrossRefGoogle Scholar
  16. 16.
    Delp SL, Komattu AV, Wixson RL: Superior displacement of the hip in total joint replacement: effects of prosthetic neck length, neck-stem angle, and anteversion angle on the moment-generating capacity of the muscles. J Orthop Res 12 (1994) 860–870CrossRefPubMedGoogle Scholar
  17. 17.
    Delp SL, Ringwelski DA, Carroll NC: Transfer of the rectus femoris: effects of transfer site on moment arms about the knee and hip. J Biomech 27 (1994) 1201–1211CrossRefPubMedGoogle Scholar
  18. 18.
    Delp SL, Loan JP: A graphics-based software system to develop and analyze models of musculoskeletal structures. Comput Biol Med 25 (1995) 21–34CrossRefPubMedGoogle Scholar
  19. 19.
    Delp SL, Arnold AS, Speers RA, Moore CA: Hamstrings and psoas lengths during normal and crouch gait: implications for muscle-tendon surgery. J Orthop Surg 14 (1996) 144–151Google Scholar
  20. 20.
    Disler DG, Peters TL, Muscoreil SJ, Rat ner LM, Wagle WA, Cousins JP, Rifkin MD: Fat-suppressed imaging of knee hyaline cartilage: technique optimization and comparison with conventional MR imaging. Am J Radiol 163 (1994) 887–892Google Scholar
  21. 21.
    Disler DG, McCauley TR, Wirth CR, Fuchs MD: Detection of knee hyaline cartilage defects using fat-suppressed three-dimensional spoiled gradient-echo MR imaging: comparison with standard MR imaging and correlation with arthroscopy. Am J Radiol 165 (1995) 377–382Google Scholar
  22. 22.
    Eckstein F, Sittek H, Milz S, Putz R, Reiser M: The morphology of articular cartilage assessed by magnetic resonance imaging (MRI): reproducibility and anatomical correlation. Surg Radiol Anat 16 (1994) 429–38CrossRefPubMedGoogle Scholar
  23. 23.
    Eckstein F, Gavazzeni A, Sittek H, Haubner M, Losch A, Milz S, Englmeier KH, Schulte E, Putz R, Reiser M: Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM). Magn Reson Med 36 (1996) 256–65CrossRefPubMedGoogle Scholar
  24. 24.
    van Eijden, TMGJ, Kouwenhoven E, Verbur GJ, Weijs WA: A mathematical model of the patellofemoral joint. J Biomech 19 (1986) 219–229CrossRefPubMedGoogle Scholar
  25. 25.
    Essinger JR, Leyvraz PF, Heegard JH, Robertson DD: A mathematical model for the evaluation of the behaviour during flexion of condylar-type knee prostheses. J Biomech 22 (1989) 1229–1241CrossRefPubMedGoogle Scholar
  26. 26.
    Fulkerson JP, Schutzer, SF: After failure of conservative treatment for painful patellofemoral malalignment: lateral release or realignment? Orthop Clin North Am 17 (1986) 283–288PubMedGoogle Scholar
  27. 27.
    Garcia-Elias M, An KN, Cooney WP, Linsc heid RL, Chao EY: Transverse stability of the carpus: an analytic study. J Orthop Res 7 (1989) 738–743CrossRefPubMedGoogle Scholar
  28. 28.
    Garg A, Walker PS: Prediction of total kn ee motion using a three-dimensional computer-graphics model. J Biomech 23 (1990) 45–58CrossRefPubMedGoogle Scholar
  29. 29.
    Heegaard J, Leyvraz PF, Curnier A, Ra kotomanana L, Huiskes R: The biomechanics of the human patella during passive knee flexion. J Biomech 28 (1995) 1265–1279CrossRefPubMedGoogle Scholar
  30. 30.
    Hirokawa S: Three-dimensional mathematical model analysis of the patellofemoral joint. J Biomech 24 (1991) 659–671CrossRefPubMedGoogle Scholar
  31. 31.
    Horii E, Garcia-Elias M, An KN, Bishop A T, Cooney WP, Linscheid RL, Caho EYS: Effect on force transmission across the carpus in procedures used to treat Kienböck’s disease. J Hand Surg 15A (1990) 393–400CrossRefGoogle Scholar
  32. 32.
    Hsu RWW, Himeno S, Coventry MB, Chao EYS: Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop 255 (1990) 215–227Google Scholar
  33. 33.
    Jupiter JB, Ruder J, Roth DA: Computer-generated bone models in the planning of osteotomy of multidirectional distal radius malunions. J Hand Surg 17A (1992) 406–415CrossRefGoogle Scholar
  34. 34.
    Kwak SD, Ateshian GA, Blankevoort L, Ahm ad, CS, Gardner TR, Grelsamer RP, Henry JH, Mow VC: A general mathematical multibody model for diarthrodial joints: application and validation using the patellofemoral joint. Adv Bioeng, ASME, BED 33 (1996) 239–240Google Scholar
  35. 35.
    Matsen FA 3rd, Garbini JL, Sidles JA, Pratt B, Baumgarten D, Kaiura R: Robotic assistance in orthopaedic surgery. Clin Orthop 296 (1993) 178–186Google Scholar
  36. 36.
    Millis MB, Murphy SB: The use of comput ed tomographic reconstruction in planning osteotomies of the hip. Clin Orthop 274 (1992) 154–159Google Scholar
  37. 37.
    Murphy SB, Kijewski PK, Simon SR, Chand ler HP, Griffin PP, Reilly DT, Penenberg BL, Landy MM: Computer-aided simulation, analysis, and design in orthopedic surgery. Orthop Clin North Am 17 (1986) 637–649PubMedGoogle Scholar
  38. 38.
    Murphy SB, Kijewski PK, Millis MB, Hall JE, Simon SR, Chandler HP: The planning of orthopaedic reconstructive surgery using computer-aided simulation and design. Comput Med Imaging & Graph 12(1988) 33–45CrossRefGoogle Scholar
  39. 39.
    Nolte LP, Zamorano LJ, Jiang Z, Wang Q, Langlotz F, Berlemann U: Image-guided insertion of transpedicular screws: a laboratory set-up. Spine 20:497–500 (1995)CrossRefPubMedGoogle Scholar
  40. 40.
    O’Toole RV, Jaramaz B, DiGioia AM 3rd, Visnic CD, Reid RH: Biomechanics for preoperative planning and surgical simulations in orthopaedics. Comput Biol Med 25 (1995) 183–191CrossRefPubMedGoogle Scholar
  41. 41.
    Paul H, Bargar WL, Mittlestadt B, Musits B, Taylor RH, Kanzanzides P, Zuhars J, Williamson B, Hanson W: Development of a surgical robot for cementless total hip arthroplasty. Clin Orthop 285 (1992) 57–66Google Scholar
  42. 42.
    Peterfy CG, van Dijke CF, Janzen DL, Gluer CG, Namba R, Majumdar S, Lang P, Genant HK: Quantification of articular articular cartilage in the knee with pulsed saturation transfer subtraction and fat-suppressed MR imaging: optimization and validation. Radiology 192 (1994) 485–491CrossRefPubMedGoogle Scholar
  43. 43.
    Peterfy CG, Majumdar S, Lang P, van Dijke CF, Sack K, Genant HK: MR Imaging of the arthritic knee: improved discrimination of cartilage, synovium, and effusion with pulsed saturation transfer and fat-supressed T1-weighted sequences. Radiology 191 (1994) 413–419CrossRefPubMedGoogle Scholar
  44. 44.
    Recht MP, Kramer J, Marcelis S, Pathria MN, Trudell D, Haghighi P, Sartoris DJ, Resnick D: Abnormalities of articular cartilage in the knee: analysis of available MR techniques. Radiology 187 (1993) 473–478CrossRefPubMedGoogle Scholar
  45. 45.
    Recht MP, Resnick D: MR imaging of articular cartilage: current status and future directions. Am J Radiol 163 (1994) 283–290Google Scholar
  46. 46.
    Roglic H, Kwak SD, Henry JH, Ateshian G A, Rodkey W, Steadman JR, Mow VC: Adhesions of the patellar and quadriceps tendons: mathematical model simulation. Adv Bioeng, ASME, BED 36 (1997) 261–262Google Scholar
  47. 47.
    Ronsky J, van den Bogert A, Nigg B: In vivo quantification of human patellofemoral joint contact. Proc Can Soc Biomech 8 (1994) 82Google Scholar
  48. 48.
    Sangeorzan BJ, Sangeorzan BP, Hansen ST, Judd RP: Mathematically directed single-cut osteotomy for correction of tibial malunion. J Orthop Trauma 3 (1989) 267–275CrossRefPubMedGoogle Scholar
  49. 49.
    Scherrer PK, Hillberry BM, Van Sickle DC: Determining the in vivo areas of contact in the canine shoulder. J Biomech Eng 101 (1979) 271–278CrossRefGoogle Scholar
  50. 50.
    Seo GS, Aoki J, Moriya H, Karakida O, Sine S, Hikada H, Katsuyama T: Hyaline cartilage: in vivo and in vitro assessment with magnetization transfer imaging. Radiology 201 (1996) 525–530CrossRefPubMedGoogle Scholar
  51. 51.
    Sutherland CJ, Bresina SJ, Gayou DE: Use of general purpose mechanical computer assisted engineering software in orthopaedic surgical planning: advantages and limitations. Comput Med Imaging Graph 18 (1994) 435–442CrossRefPubMedGoogle Scholar
  52. 52.
    Tan TCF, Wilcox DM, Frank L, Shih C, Trudell DJ, Sartoris DJ, Resnick D: MR imaging of articular cartilage in the ankle: comparison of available imaging sequences and methods of measurement in cadavers. Skeletal Radiol 25 (1996) 749–755CrossRefPubMedGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 1998

Authors and Affiliations

  • Zohara A. Cohen
    • 1
    • 2
  • Denise M. McCarthy
    • 3
  • Hrvoje Roglic
    • 1
    • 2
  • Jack H. Henry
    • 2
  • William G. Rodkey
    • 4
  • J. Richard Steadman
    • 4
  • Van C. Mow
    • 1
    • 2
  • Gerard A. Ateshian
    • 1
    • 2
  1. 1.Department of Mechanical EngineeringColumbia UniversityNew York
  2. 2.Orthopaedic Research Laboratory, Department of Orthopaedic SurgeryColumbia-Presbyterian Medical CenterNew York
  3. 3.Department of RadiologyColumbia-Presbyterian Medical CenterNew York
  4. 4.Steadman-Hawkin Sports Medicine FoundationVail

Personalised recommendations