Abstract
The theme of project aims to perform as well as the strength of a base isolation system for reference firm structures for the period of seismic events. The purpose of presenting a 3D referenced concrete frame building with safe position as a case study, using SAP 2000 software for modeling and analysis. Seismic load calculations can be performed according to IS 1893–2016 to meet earthquake-resistant resolution. This study addresses a 3-D reinforced concrete frame structure with dimensions of 21 m on the x-axis and 21 m on the y-axis, comprising a G + 6 configuration with a height of 24 m. The objective is to increase the natural time period, reduce level drift, and lower the acceleration response of seismic events. The paper evaluates the effectiveness of the base isolation system in terms of maximum shear force, maximum bending moment, base shear, level drift, and level relocation reductions.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Alberti (2023) Shake-table test assessment of a base-isolation device for the seismic protection of the Goddess of Morgantina statue. 473–478. https://doi.org/10.21741/9781644902431-77
Giacomo B, Paolo C, Ugo I, Chiara O, Federico S (2023) Observed seismic behaviour of base isolation systems in Italy. https://doi.org/10.1007/978-3-031-21187-4_50
Bruno C (2017) Base isolation from a historical perspective
Amol C, Yashraj M, Sanket M, Ganesh G, Manisha SS (2022) Study of base isolation. 04:862–867
Ronwyn C, Eric S, Jacobus V (2022) Base isolation: mind the gap. 9(2):AAE-07. https://doi.org/10.14455/ISEC.2022
Hamed D, Mahsa N (2018) Appropriate base stiffness of smart base isolation system. Malaysian J Civil Eng 30
El-Assaly M, Amin M, Saad S (2022) Regular versus vertical irregular R.C buildings using base isolation. 26–33. https://doi.org/10.9790/1684-1804022633
Cristiano F, Angelo D (2015) Base isolation versus top isolation
Wang F, Yuli H, Zhe Q (2023) Limitation of base isolation in protectingfreestanding contents in buildings. Earthquake Eng Struct Dynam 52.https://doi.org/10.1002/eqe.3844
Pushkar K, Hema M, Suhasini M (2023) Effectiveness of base isolation systems for seismic response control of masonry dome
Kiran KK, Jagadish G (2022) Blast Mitigation of SDOF systems by using M.R. Damper and Base Isolations. In: ASPS conference proceedings, pp 1095–1100. https://doi.org/10.38208/acp.v1.626
Sooraj K, Ganesh J (2022) Effect of base isolation using LRB on stepped building. Int J Res Appl Sci Eng Technol 10:4324–4330. https://doi.org/10.22214/ijraset.2022.45990
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2024 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Radhavaram, A., Anand Goud, K., Prasad, J.S.R. (2024). Performance Analysis of Fixed and Seismic Base Isolation System for Multi-story Building. In: Sreekeshava, K.S., Kolathayar, S., Vinod Chandra Menon, N. (eds) Recent Advances in Structural Engineering. IACESD 2023. Lecture Notes in Civil Engineering, vol 455. Springer, Singapore. https://doi.org/10.1007/978-981-99-9502-8_14
Download citation
DOI: https://doi.org/10.1007/978-981-99-9502-8_14
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-99-9501-1
Online ISBN: 978-981-99-9502-8
eBook Packages: EngineeringEngineering (R0)