Abstract
In this paper, the phase-locked loop less (PLL) control technique has been investigated using four legs VSC-based D-STATCOM for unity power factor (UPF) mode. It is implemented using the MATLAB/Simulink environment. Further without PLL, the performance of D-STATCOM is measured graphically. The proposed technique is suitable for reactive power compensation, source current harmonic elimination and load balancing with linear and nonlinear load. The observation of simulated results of D-STATCOM provides the effective solution for power quality enhancements at steady-state and dynamic load.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Dugan RC, Mc Granaghan MF, Beaty HW (2006) Electric power systems quality, 2nd edn. MC Graw Hill, New York
Kusko A, Thompson MT (2007) Power quality in electrical system. McGraw Hill Professional, Maidenherd
Arrillaga J, Watson NR (2004) Power system harmonics. Wiley, Hoboken
IEEE recommended practices and requirement for harmonic control on electric power system, IEEE Std. 519 (1992)
Wu JC, Jou HL, Feng YT, Hsu WP, Huang MS, Hou WJ (2007) Novel circuit topology for three-phase active power filter. IEEE Trans Power Del 22(1):444–449
Jou HL, Wu KD, Wu JC, Li CH, Huang MS (2008) Novel power converter topology for three phase four-wire hybrid power filter. IET Power Electr 1(1):164–173
Singh B, Solanki J (2011) Load compensation for diesel generator-based isolated generation system employing DSTATCOM. IEEE Trans Ind Appl 47(1):238–244
Jayaprakash P, Singh B, Kothari DP (2008) Three-phase 4-wire DSTATCOM based on H-bridge VSC with a star/hexagon transformer for power quality improvement. In: Proceedings of IEEE region 10 and the third international conference on industrial and information systems (ICIIS). IEEE, Kharagpur, India, pp 1–6
Singh B, Arya SR (2014) Adaptive control of four-leg VSC based DSTATCOM in distribution system. Int J Emerg Electr Power Syst 15(1):93–99
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Appendix
Appendix
Three-phase AC supply 100 V (L-L), 50 Hz, source impedance Zs (R = 0.05 Ω, L = 0.2 mH. |
(1) Three-phase nonlinear load, R = 13.66 Ω, L = 10 mH, |
(2) Nonlinear load (A-N) R = 15 Ω, L = 100 mH. |
DC link capacitance and voltage Cdc = 3000 µF and Vdc = 300 V, interfacing inductor = 2 mH. |
Rights and permissions
Copyright information
© 2021 The Editor(s) (if applicable) and The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Ram, A., Sharma, P.R., Ahuja, R.K., Goel, N. (2021). PLL Less Control Algorithm for Power Quality Improvement in Distribution System Using D-STATCOM. In: Favorskaya, M.N., Mekhilef, S., Pandey, R.K., Singh, N. (eds) Innovations in Electrical and Electronic Engineering. Lecture Notes in Electrical Engineering, vol 661. Springer, Singapore. https://doi.org/10.1007/978-981-15-4692-1_9
Download citation
DOI: https://doi.org/10.1007/978-981-15-4692-1_9
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-15-4691-4
Online ISBN: 978-981-15-4692-1
eBook Packages: EnergyEnergy (R0)