Skip to main content

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 638))

  • 940 Accesses

Abstract

In recent years, the reliability requirements of active neutral-point-clamped (ANPC) three-level converter are getting higher and higher with its large-scale application. In order to overcome the problem of the limited fault-tolerant capability of the basic ANPC three-level converter when compound faults occur, an improved fault-tolerant topology based on component sharing was proposed in this paper. Compared with the basic ANPC three-level converter topology, two bidirectional thyristors and a double-pole double-throw switch are added to each phase, which can realize Fault-Tolerant Control (FTC) for multiple fault types and greatly improve the reliability with small additional costs. The corresponding self-diagnosis FTC algorithm composed of topology reconfiguration module, switch state generation module, and PWM output control module is also put forward. With the real-time generation of switch state, the reconfiguration of fault-tolerant topology is easy to realize and adaptable. Finally, the effectiveness and feasibility of the proposed topology and FTC algorithm are verified by simulation and experimental results.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 299.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 379.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 379.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Findings on Energy Reported by Investigators at Konkuk University (2018) A Harmonic Voltage Injection Based DC-Link Imbalance Compensation Technique for Single-Phase Three-Level Neutral-Point-Clamped (NPC) Inverters. Energy Weekly News

    Google Scholar 

  2. Hui L, Ran Y, Wei L, Hai R, Jinyuan L (2019) Modeling and analysis on overall fatigue failure evolution of press-pack IGBT device. IEEE Trans Electron Devices 66(3):1435–1443

    Article  Google Scholar 

  3. Xulong Z, Feng W, Wen J, Shuyun Q, Yanjing C (2017) Fault tolerant control method for three-level photovoltaic inverter based on redundant voltage space vector. In: 2017 36th Chinese Control Conference (CCC), Dalian, pp 9249–9253

    Google Scholar 

  4. Qinyue Z, Lei G, Xitang T, Wenlong L, Ling T (2017) Four-leg fault-tolerant control of traction inverter for composite fault. J Power Supply 15(02):59–66 (in Chinese)

    Google Scholar 

  5. Wenxuan F, Peng Z, Yu W et al (2017) Research on fault tolerant control of three-level ANPC converter under open-circuit fault. Power Electron 51(03):4–8

    Google Scholar 

  6. Rocha AV, Silva SM, Pires IA (2014) A new fault-tolerant realization of the active three-level NPC converter. In: Energy Conversion Congress and Exposition, IEEE, pp 3483–3490

    Google Scholar 

  7. Fengjun L (2007) Multi-level inverter technology and its application. China Machine Press, China (in Chinese)

    Google Scholar 

  8. Hangpeng X, Quan C, Guoli L, Xiang D (2019) Research on neutral-point voltage balance of three-level NPC inverter based on improved SVPWM. Mod Electron Tech 42(04):129–133 (in Chinese)

    Google Scholar 

  9. Jun H, Cungang H, Zhongyuan W (2015) Study on SVPWM method based on KL coordinate system for three-level ANPC inverter. In: 2015 IEEE 10th Conference on Industrial Electronics and Applications (ICIEA), Auckland, pp 1637–1640

    Google Scholar 

  10. Byong-Gun P, Jae-Woon L, Min-Hyuk A, Soon-Man K, Ji-Won K (2018) Simple fault-tolerant control using unified voltage modulation for Active Neutral Point Clamped (ANPC) three-level inverter. In: 2018 IEEE 18th International Power Electronics and Motion Control Conference (PEMC), Budapest, pp 1031–1037

    Google Scholar 

  11. Liu L, Yin J, Jin G, Zhou P (2017) Simulation of traction drive control system of high-speed EMUs. Electr Drive Autom 39:12–15 (in Chinese)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xitang Tan .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Zhu, Q., Wang, C., Tan, X., Zhang, P., Fan, Q. (2020). Research on the Improved Fault-Tolerant Control of ANPC Three-Level Converter. In: Jia, L., Qin, Y., Liu, B., Liu, Z., Diao, L., An, M. (eds) Proceedings of the 4th International Conference on Electrical and Information Technologies for Rail Transportation (EITRT) 2019. EITRT 2019. Lecture Notes in Electrical Engineering, vol 638. Springer, Singapore. https://doi.org/10.1007/978-981-15-2862-0_41

Download citation

  • DOI: https://doi.org/10.1007/978-981-15-2862-0_41

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-15-2861-3

  • Online ISBN: 978-981-15-2862-0

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics