Abstract

This is all about harmonic the current mitigation (as one of the major power quality issues) through the imaginary power owing to their precise and audacious action by shunt active filter (ShAF) build on sinusoidal current control strategy (SCCS) in a grid-tied PV system. The SCCS is employed to liberate sinusoidal current commenced from the supply additionally with a burly synchronizing (phase-locked loop) circuit, concise the controller for ShAF. Explicitly by a sinusoidal current control based controller, ShAF acts as a harmonic isolator amidst with load and supply. The performance of the said technique is evaluated using MATLAB R2016a under passive load (nonlinear load), and the observations are discussed. The efficacy of the ShAF in harmonics mitigation is validated through the proposed simulation. The total harmonic distortion (THD) of current and voltage ascertains controller’s practicability for the ShAF delivering harmonic separation of passive loads in the grid-tied hybrid energy system.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Aredes M, Hafner J, Heumann K (1997) Three-phase fourwire shunt active filter control strategies. IEEE Trans Power Electron 12(2):311–318

    Article  Google Scholar 

  2. Senthilkumar A, Poongothai K, Selvakumar S, Silambarasan M, Raj PADV (2015) Mitigation of harmonic distortion in microgrid system using adaptive neural learning algorithm based shunt active power filter. Procedia Technol 21:147–154

    Google Scholar 

  3. Akagi H, Watanabe EH, Aredes M (2007) Instantaneous power theory and applications to power conditioning, vol 31. Wiley

    Google Scholar 

  4. Senapati R, Sahoo RK, Senapati RN, Panda PC (2016) Performance evaluation of sinusoidal current control strategy unified power quality conditioner. In: International conference on electrical, electronics, and optimization techniques (ICEEOT), pp 1404–1408. IEEE

    Google Scholar 

  5. Senapati R, Sahoo RK, Pradhan S, Senapati RN (2017, August). Sinusoidal current control strategy for 3-phase shunt active filter in grid-tied PV system. In: 2017 International conference on energy, communication, data analytics and soft computing (ICECDS), pp 1272–1277. IEEE

    Google Scholar 

  6. Senapati R (2018) Study and analysis of performance of 3-phase shunt active filter in grid-tied PV-fuel cell system employing sinusoidal current control strategy. Int J Renew Energy Res (IJRER) 8(1):67–81

    Google Scholar 

  7. Senapati R, Senapati RN, Behera P, Moharana MK (2016, October) Performance analysis of unified power quality conditioner in a grid connected PV system. In: 2016 International conference on signal processing, communication, power and embedded system (SCOPES), pp 416–420. IEEE

    Google Scholar 

  8. Jain SK, Agrawal P, Gupta HO (2002) Fuzzy logic controlled shunt active power filter for power quality improvement. IEE Proc-Electr Power Appl 149(5):317–328

    Article  Google Scholar 

  9. Tang Y, Loh PC, Wang P, Choo FH, Gao F, Blaabjerg F (2012) Generalized design of high performance shunt active power filter with output LCL filter. IEEE Trans Ind Electron 59(3):1443–1452

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sthita Prajna Mishra .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Senapati, R., Mishra, S.P., Illa, V., Senapati, R.N. (2020). Improvement of the Current Profile in Grid-Tied Hybrid Energy System by Three-Phase Shunt Active Filter. In: Sharma, R., Mishra, M., Nayak, J., Naik, B., Pelusi, D. (eds) Innovation in Electrical Power Engineering, Communication, and Computing Technology. Lecture Notes in Electrical Engineering, vol 630. Springer, Singapore. https://doi.org/10.1007/978-981-15-2305-2_4

Download citation

  • DOI: https://doi.org/10.1007/978-981-15-2305-2_4

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-15-2304-5

  • Online ISBN: 978-981-15-2305-2

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics