Abstract
This is all about harmonic the current mitigation (as one of the major power quality issues) through the imaginary power owing to their precise and audacious action by shunt active filter (ShAF) build on sinusoidal current control strategy (SCCS) in a grid-tied PV system. The SCCS is employed to liberate sinusoidal current commenced from the supply additionally with a burly synchronizing (phase-locked loop) circuit, concise the controller for ShAF. Explicitly by a sinusoidal current control based controller, ShAF acts as a harmonic isolator amidst with load and supply. The performance of the said technique is evaluated using MATLAB R2016a under passive load (nonlinear load), and the observations are discussed. The efficacy of the ShAF in harmonics mitigation is validated through the proposed simulation. The total harmonic distortion (THD) of current and voltage ascertains controller’s practicability for the ShAF delivering harmonic separation of passive loads in the grid-tied hybrid energy system.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Aredes M, Hafner J, Heumann K (1997) Three-phase fourwire shunt active filter control strategies. IEEE Trans Power Electron 12(2):311–318
Senthilkumar A, Poongothai K, Selvakumar S, Silambarasan M, Raj PADV (2015) Mitigation of harmonic distortion in microgrid system using adaptive neural learning algorithm based shunt active power filter. Procedia Technol 21:147–154
Akagi H, Watanabe EH, Aredes M (2007) Instantaneous power theory and applications to power conditioning, vol 31. Wiley
Senapati R, Sahoo RK, Senapati RN, Panda PC (2016) Performance evaluation of sinusoidal current control strategy unified power quality conditioner. In: International conference on electrical, electronics, and optimization techniques (ICEEOT), pp 1404–1408. IEEE
Senapati R, Sahoo RK, Pradhan S, Senapati RN (2017, August). Sinusoidal current control strategy for 3-phase shunt active filter in grid-tied PV system. In: 2017 International conference on energy, communication, data analytics and soft computing (ICECDS), pp 1272–1277. IEEE
Senapati R (2018) Study and analysis of performance of 3-phase shunt active filter in grid-tied PV-fuel cell system employing sinusoidal current control strategy. Int J Renew Energy Res (IJRER) 8(1):67–81
Senapati R, Senapati RN, Behera P, Moharana MK (2016, October) Performance analysis of unified power quality conditioner in a grid connected PV system. In: 2016 International conference on signal processing, communication, power and embedded system (SCOPES), pp 416–420. IEEE
Jain SK, Agrawal P, Gupta HO (2002) Fuzzy logic controlled shunt active power filter for power quality improvement. IEE Proc-Electr Power Appl 149(5):317–328
Tang Y, Loh PC, Wang P, Choo FH, Gao F, Blaabjerg F (2012) Generalized design of high performance shunt active power filter with output LCL filter. IEEE Trans Ind Electron 59(3):1443–1452
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Senapati, R., Mishra, S.P., Illa, V., Senapati, R.N. (2020). Improvement of the Current Profile in Grid-Tied Hybrid Energy System by Three-Phase Shunt Active Filter. In: Sharma, R., Mishra, M., Nayak, J., Naik, B., Pelusi, D. (eds) Innovation in Electrical Power Engineering, Communication, and Computing Technology. Lecture Notes in Electrical Engineering, vol 630. Springer, Singapore. https://doi.org/10.1007/978-981-15-2305-2_4
Download citation
DOI: https://doi.org/10.1007/978-981-15-2305-2_4
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-15-2304-5
Online ISBN: 978-981-15-2305-2
eBook Packages: EngineeringEngineering (R0)