Abstract
Passive settle plate method and active impaction method are two most commonly used methods for bioaerosols’ sampling and surveillance. Passive method is a relatively low-cost method for bioaerosols’ surveillance. The current study intends to compare the efficiency of active and passive methods of bioaerosol sampling for temporal surveillance at different source sites. It was observed that the temporal measurements of bioaerosol by both methods were strongly correlated. Thus, both methods can be used for bioaerosol surveillance. The results of effect of putative factors by both methods were relatively comparable to a larger extent. This finding is highly significant for resource constraint setting where the use of active method is not cost effective for temporal surveillance and research purpose.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Heseltine E, Rosen J (2009) WHO guidelines for indoor air quality: dampness and mould. WHO Regional Office, Europe
Wanner HU, Gravesen S (1993) Biological particles in indoor environments: European collaborative action. Indoor air quality & its impact on man. Report No. 12. Commission of the European Communities, Luxembourg
Obbard JP, Fang LS (2003) Airborne concentrations of bacteria in a hospital environment in Singapore. Water Air Soil Pollut 144:333–341
Dumała SM, Dudzińska MR (2013) Microbiological indoor air quality in Polish schools. Ann Set Environ Prot 15:231–244
de Aquino Neto FR, de Góes Siqueira LF (2004) Guidelines for indoor air quality in offices in Brazil. Proc Healthy Build 4:549–554
Nunes ZG, Martins AS, Altoe AL, Nishikawa MM, Leite MO, Aguiar PF, Fracalanzza SE (2005) Indoor air microbiological evaluation of offices, hospitals, industries, and shopping centers. Memórias do Instituto Oswaldo Cruz 100:351–357
Bartlett KH, Lee KS, Stephens G, Black W, Brauer M, Copes R (2003) Evaluating indoor air quality: test standards for bioaerosols. Report to The Workers’ Compensation Board of British Columbia Research Secretariat 99FS-64
Pegas PN, Evtyugina MG, Alves CA, Nunes T, Cerqueira M, Franchi M, Pio C, Almeida SM, Freitas MD (2010) Outdoor/indoor air quality in primary schools in Lisbon: a preliminary study. Quim Nova 33:1145–1149
Jo WK, Seo YJ (2005) Indoor and outdoor bioaerosol levels at recreation facilities, elementary schools, and homes. Chemosphere 61:1570–1579
Napoli C, Marcotrigiano V, Montagna MT (2012) Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres. BMC Public Health 12:594
Pasquarella C, Albertini R, Dall’Aglio P, Saccani E, Sansebastiano GE, Signorelli C (2008) Air microbial sampling: the state of the art. Igiene e sanitapubblica 64:79–120
Whyte W (1986) Sterility assurance and models for assessing airborne bacterial contamination. PDA J Pharma Sci Tech 40:188–197
Orpianesi C, Cresci A, La Rosa F, Saltalamacchia G, Tarsi R (1982) Evaluation of microbial contamination in a hospital environment. Comparison between the surface air system and the traditional method. Nuoviannalid’igiene e microbiologia 34:171–185
Sabharwal ER, Sharma R (2015) Estimation of microbial air contamination by settle plate method: are we within acceptable limit. Sch Acad J Biosci 3(8):703–707
Balyan P, Ghosh C, Das S, Banerjee BD (2017) Spatial variation of biogenic aerosols at different land use configurations in urban Delhi. Int J Appl Environ Sci 12:731–744
Charnley J (1972) Postoperative Infection after total hip replacement with special reference to air contamination in the operating room. ClinorthoRelat Res 87:167–187
French MLV, Eitzen HE, Ritter MA, Leland DS (1980) Environmental Control of microbial contamination in the operating room. In: Wound healing and wound infection. New York, pp 254–261
Perdelli F, Sartini M, Orlando M, Secchi V, Cristina ML (1999) Relationship between settling microbial load and suspended microbial load in operating rooms. Annali di igiene: medicinapreventiva e di comunita 12:373–380
Petti S, Iannazzo S, Tarsitani G (2002) Comparison between different methods to monitor the microbial level of indoor air contamination in the dental office. Annali di igiene: medicinapreventiva e di comunita 15:725–733
Sayer WJ, MacKnight NM, Wilson HW (1972) Hospital airborne bacteria as estimated by the Andersen sampler versus the gravity settling culture plate. Am J ClinPathol 58:558–566
Mandal J, Brandl H (2011) Bioaerosols in indoor environment-a review with special reference to residential and occupational locations. Open Environ BiolMonit J 4:83–96
Saha R, Agarawal S, Khan AM (2017) Air sampling procedures to evaluate microbial contamination: A comparison between active and passive methods at high-risk areas in a Tertiary Care Hospital of Delhi. J Patient Saf Infect Control 5:18–23
Acknowledgements
Authors are thankful to Department of Science and Technology (DST) Purse Grant and Ministry of Environment, Forest and Climate Change (MoEF), Government of India, for supporting the research work financially.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Balyan, P., Ghosh, C., Das, S., Banerjee, B.D. (2020). Comparison of Efficiency of Active and Passive Methods of Bioaerosols’ Estimation. In: Sharma, A., Goyal, R., Mittal, R. (eds) Indoor Environmental Quality. Lecture Notes in Civil Engineering, vol 60. Springer, Singapore. https://doi.org/10.1007/978-981-15-1334-3_10
Download citation
DOI: https://doi.org/10.1007/978-981-15-1334-3_10
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-15-1333-6
Online ISBN: 978-981-15-1334-3
eBook Packages: EngineeringEngineering (R0)