Skip to main content

Pulse Oximetry and Capnography

  • Chapter
  • First Online:
ICU Protocols

Abstract

A 50-year-old male patient, a known case of chronic obstructive pulmonary disease (COPD), was admitted to the hospital with acute exacerbation. He was drowsy and cyanotic. His respiratory rate was 26/min. He was admitted for the management of COPD.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 99.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 129.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 199.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Suggested Reading

  • Biais M, Berthezène R, Petit L, Cottenceau V, Sztark F. Ability of esCCO to track changes in cardiac output. Br J Anaesth. 2015;115(3):403–10. They investigated whether cardiac output measured with pulse wave transit time (esCCO, Nihon Kohden) was able to track changes in cardiac output induced by an increase in preload (volume expansion/passive leg-raising) or by changes in vasomotor tone (variation in norepinephrine dosage) in critically ill patients.

    Article  CAS  Google Scholar 

  • Cheifetz IM, Myers TR. Respiratory therapies in the critical care setting. Should every mechanically ventilated patient be monitored with capnography from intubation to extubation? Respir Care. 2007;52(4):423–38.

    PubMed  Google Scholar 

  • Desebbe O, Cannesson M. Using ventilation induced plethysmo-graphic variations to optimize patient fluid status. Curr Opin Anaesthesiol. 2008;21:772–8. Automatic detection of respiratory variations in pulse oximetry plethysmographic waveform amplitude can predict fluid responsiveness in the operating room in patients under mechanical ventilation and has potential for fluid optimization in this setting

    Article  Google Scholar 

  • Feiner JR, Severinghaus JW. Effects of skin pigmentation on pulse oximeter accuracy at low saturation. Anesthesiology. 2005;102(4):715–9. Pulse oximeters overestimate arterial oxygen saturation during hypoxia in dark-skinned individuals.

    Article  Google Scholar 

  • Hampson NB. Pulse oximetry in severe carbon monoxide poisoning. Chest. 1998;114(4):1036–41. Presently available pulse oximeters overestimate arterial oxygenation in patients with severe CO poisoning. Accurate assessment of arterial oxygen content in patients with CO poisoning can currently be performed only by analysis of arterial blood with a laboratory CO-oximetry

    Article  CAS  Google Scholar 

  • Kamat V. Pulse oximetry. Indian J Anaesth. 2002;46(4):261–8. Despite problems and limitations, pulse oximetry remains the standard of care in all clinical situations, and its use for all patients under anesthesia must be mandated

    Google Scholar 

  • Nagler J, Krauss B. Capnography: a valuable tool for airway management. Emerg Med Clin North Am. 2008;26(4):881–97. Clinical applications of capnography with regard to ventilation and airway management are discussed.

    Article  Google Scholar 

  • Van de Louw A, Cracco C. Accuracy of pulse oximetry in the intensive care unit. Intensive Care Med. 2001;27(10):1606–13. Large SpO2 to SaO2 differences may occur in critically ill patients with poor reproducibility of SpO2. A SpO2 above 94% appears necessary to ensure an SaO2 of 90%.

    Article  Google Scholar 

  • Verscheure, et al. Volumetric capnography: lessons from the past and current clinical applications. Crit Care. 2016;20:184. This is a comprehensive review of volumetric capnography and they have discussed the components of dead space, explained important differences between the Bohr and Enghoff approaches, discussed the clinical significance of arterial to end-tidal CO2 gradient and finally summarized potential clinical indications for Vcap measurements in the emergency room, operating room and ICU.

    Article  Google Scholar 

  • Walsh BK, Crotwell DN, Restrepo RD. Capnography/Capnometry during mechanical ventilation. Respir Care. 2011;56(4):503–9. This updated clinical practice guideline is based on 234 clinical studies and systematic reviews, 19 review articles investigating the use of capnography/capnometry during mechanical ventilation.

    Article  Google Scholar 

  • Wilson BJ, Cowan HJ, Lord JA. The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort study. BMC Emerg Med. 2010;10:9. Pulse oximetry overestimates ABG-determined SaO2 by a mean of 2.75% in emergency department patients with severe sepsis and septic shock. This overestimation is exacerbated by the presence of hypoxemia. When SaO2 needs to be determined with a high degree of accuracy, arterial blood gases are recommended.

    Article  Google Scholar 

Websites

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Singapore Pte Ltd.

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Govil, D., Gupta, S., Srivastava, A. (2020). Pulse Oximetry and Capnography. In: Chawla, R., Todi, S. (eds) ICU Protocols. Springer, Singapore. https://doi.org/10.1007/978-981-15-0898-1_17

Download citation

  • DOI: https://doi.org/10.1007/978-981-15-0898-1_17

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-15-0897-4

  • Online ISBN: 978-981-15-0898-1

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics