Abstract
Microcomputer protection indicated the protection device enter the intelligent era. Over years’ operation, a huge amount of data has been accumulated. Unfortunately, mass data has not been used effectively. The development of Internet technology brings protection into information age. Two typical applications are presented in this paper. One is abnormal protection channel interruption analysis; the other is breaker defect identification. Combining the data of the Protection and Fault Recorder Management System (PFRMS) with the data of the Communication Network Management System (CNMS), abnormal interruption analysis of the protection channel is studied in this paper. It effectively extracts the channel anomaly events that need to be focused on by the protection engineer. As for breaker defect, the characteristics of each time link in the fault isolation process are analyzed. The wavelet transform is used to capture the separation moment of the contact. The arc extinguishing time is analyzed to evaluate the arc extinguishing chamber. By cluster analysis, each time duration of fault isolation is calculated, the abnormal points differ from others can be found out easily, which means there is an abnormality in the secondary circuit of the breaker.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Wang S, Zhao D (2017) Research review and prospects for power grid fault diagnosis. Autom Electr Power Syst 41(19):164–175
Zhou N, Liao J, Wang Q et al (2019) Analysis and prospect of deep learning application in smart grid. Autom Electr Power Syst 43(4):180–191
Wang J, Wang D, Yang G, Zhou Z, Deng C (2016) Research and application of big data technology in relay protection. 14(12):1–7
Leng X, Chen G, Bai J et al (2018) General design of smart grid monitoring operation big data analysis system. Autom Electr Power Syst 42(12):160–166
Gao H, Sun M, Yu J, Zheng M, Cong W, Huang J, Wu F Anomaly correlation analysis method for line protection channel based on multi-source data. Southern Power Syst Technol 12(8):37–43
Zhang Y, Mou X, Ma Y (2017) Study on the alarm on—The acquisition system for protection photoelectric conversion device and automatic analysis and localization method for protection channel fault. Power Syst Prot Control 45(20):158–163
Wang Y (2015) Research on multi-dimension analysis methods of communication network alarm. J Netw New Media 4(4):9–13
Li G, Zhang B, Zhao W et al (2018) Data science issues in state evaluation of power equipment: challenges and prospects. Autom Electr Power Syst 42(21):10–20
Yu G, Lv J (2014) Application of big data mining analysis in power equipment state assessment. Southern Power Syst Technol 8(6):74–77
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Zheng, M., Yu, J., Ding, X., Li, X., Wu, K., Liang, J. (2020). Application of Big Data Technology in Protection Channel Interruption Analysis and Breaker Defect Identification. In: Xue, Y., Zheng, Y., Rahman, S. (eds) Proceedings of PURPLE MOUNTAIN FORUM 2019-International Forum on Smart Grid Protection and Control. PMF PMF 2019 2021. Lecture Notes in Electrical Engineering, vol 584. Springer, Singapore. https://doi.org/10.1007/978-981-13-9779-0_3
Download citation
DOI: https://doi.org/10.1007/978-981-13-9779-0_3
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-9778-3
Online ISBN: 978-981-13-9779-0
eBook Packages: EnergyEnergy (R0)