Research on Energy Consumption Data Characteristics of Office Building VRV Air Conditioning Outdoor Unit Based on Energy Consumption Monitoring Platform

  • Conference paper
  • First Online:
Proceedings of the 11th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC 2019) (ISHVAC 2019)

Part of the book series: Environmental Science and Engineering ((ENVENG))

  • 1842 Accesses

Abstract

For VRV outdoor unit, the energy consumption models of air conditioning are not preferably fit for the identification and repair of data in the energy consumption monitoring platform. New characteristic models are established to provide useful assist in the identification and repair of data in this paper. Firstly, the energy consumption data of VRV outdoor unit are classified into different energy consumption modes. Secondly, the relation between data and the influencing factors of VRV outdoor unit is analyzed and the correlation coefficients are calculated. Then the influencing factor in which correlation coefficient is greater than or equal to 0.3 is selected as input variables in characteristic models. Finally, the characteristic models are established and calculated values are reckoned. The maximum average relative error between calculated value and the actual energy consumption value is within acceptable limits under different energy consumption modes.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Yang, S., et al.: Data processing method for public building energy consumption monitoring systems based on data mining. Heating Ventilating Air Conditioning 2, 82–86 (2015)

    Google Scholar 

  2. Wu, W., et al.: A method of identification and repair of energy consumption data of monitored building based on machine learning algorithm. In: Construction Science and Technology (2017)

    Google Scholar 

  3. Chen, Y., et al.: Flow meter fault isolation in building central chilling systems using wavelet analysis. Energy Conserv. Manage. 47(13), 1700–1710 (2006)

    Article  Google Scholar 

  4. Li, Q., et al.: Cluster analysis of hourly usage ratio of lighting and equipments energy use in office buildings. J. Chongqing Jianzhu Univ. 36(5) (2014)

    Google Scholar 

  5. Liu, C., et al.: Analysis on the operational power consumption of the VRV air-conditioning system and centralized air-conditioning system based on building energy monitoring and management system. Build. Sci. 32(6), 108–115 (2016)

    Google Scholar 

  6. Liu, J., et al.: An investigation of thermal comfort adaptation behavior in office buildings in the UK. Indoor Built Environ. 24(5), 675–691 (2014)

    Article  Google Scholar 

Download references

Acknowledgements

The study has been supported by the National Key R&D Program of China (Grant No. 2017YFC0704200).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Liangdong Ma .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Ma, L., Lu, F., Zhang, J., Xu, Y. (2020). Research on Energy Consumption Data Characteristics of Office Building VRV Air Conditioning Outdoor Unit Based on Energy Consumption Monitoring Platform. In: Wang, Z., Zhu, Y., Wang, F., Wang, P., Shen, C., Liu, J. (eds) Proceedings of the 11th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC 2019). ISHVAC 2019. Environmental Science and Engineering(). Springer, Singapore. https://doi.org/10.1007/978-981-13-9528-4_134

Download citation

Publish with us

Policies and ethics