Abstract
The local heat island effect (LHIE) plays an important role in the energy consumption of precision air-conditioning system, the data center cooling system. This paper conducted a field survey on the LHIE caused by precision air-conditioning system and its effect on the energy efficiency of the cooling system. The inlet and outlet air temperature and air velocity of the air cooled condenser (outdoor component of precision air conditioner), and also the environment temperature, are measured and applied in the analysis. The results show that the average inlet air temperature of outdoor units of the precision air-conditioning is 8 °C warmer than the environment air temperature, and the inlet airspeed is slow. The existence of the LHIE will be resulting 24% more energy consumption of the tested precision air-conditioning system. This paper verified the existence of LHIE and offers a reference for further study of it.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Zhang, L.F., et al.: Research on influence of cold channel closure on airflow distribution and energy efficiency in the data center computer room. Electr. Power Inf. Commun. Technol. 16(5), 63–67 (2018)
Liu, C., et al.: Analysis and protection strategy of power data center security based on cloud computing and SDN technology. Electron. Des. Eng. 24(9), 136–138, 143 (2016)
Wang, Q., et al.: Discussion on the feasibility for distributed energy in internet data center. Power Syst. Clean Energy 29(9), 87–91 (2013)
Wang, X.Y.: Discussion on cloud computing data center construction. Comput. Eng. Softw. 35(2), 129–130 (2014)
Zhou, D., et al.: Numerical simulation of thermal environment for outdoor units at building re-entrant. J. Guangzhou Univ. (Nat. Sci. Ed.) 9(6), 17–22 (2010)
You, B., et al.: The analysis and optimization on heat dissipation of outdoor unit of air conditioner. J. Shunde Polytech. 7(4), 35–38 (2009)
Xue, H., et al.: Prediction of temperature rise near condensing units in the confined space of a high-rise building. Build. Environ. 42(7), 2480–2487 (2007)
Gong, G.C., et al.: The influence of condensation heat emission on environment of outdoor air conditioner. In: 2006 National Academic Annual Conference on HVAC Refrigeration 809 (2007)
Acknowledgements
The authors acknowledge the support from the Bes. Tech, Inc for the field survey of this study.
Permissions Appropriate permissions from responsible authorities were obtained for this study in the field survey on the Data Center.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Chen, M., Ma, Z., Liu, M. (2020). The Field Survey on Local Heat Island Effect of Precision Air-Conditioning. In: Wang, Z., Zhu, Y., Wang, F., Wang, P., Shen, C., Liu, J. (eds) Proceedings of the 11th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC 2019). ISHVAC 2019. Environmental Science and Engineering(). Springer, Singapore. https://doi.org/10.1007/978-981-13-9524-6_86
Download citation
DOI: https://doi.org/10.1007/978-981-13-9524-6_86
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-9523-9
Online ISBN: 978-981-13-9524-6
eBook Packages: Earth and Environmental ScienceEarth and Environmental Science (R0)