Abstract
Calibrating the absolute spectral responsivity is of great importance, because this guides the design and application of terahertz detectors. In this paper, we build a calibration system, and this system can be used to calibrate absolute spectral responsivity of terahertz detectors at a serial of frequencies such as 0.84, 1.63, 2.52, 4.25 THz et al. The key components of the system include a standard terahertz detector and a terahertz gas laser, and other components such as TPX lens and ultrasensitive voltmeter are also included. The calibration system was employed to calibrate a terahertz detector with the model of 12D-3S-VP produced by Gentec Inc., and the absolute spectral responsivity of 193.8 mV/W at 2.52 THz was obtained. The measurement uncertainty is analyzed to be 6.0%. This work not only offers method and system to terahertz detector calibration, but also contributes to high accuracy terahertz power measurement and terahertz device calibration.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Steiger, A., Gutschwager, B., Kehrt, M., Monte, C., Müller, R., Hollandt, J.: Optical methods for power measurement of terahertz radiation. Opt. Express 18(21), 21804–21814 (2010)
Steiger, A., Muller, R.: Traceable calibration of Terahertz detectors. In: Conference on Precision Electromagnetic Measurements (CPEM), pp. 256–257. IEEE (2012)
Steiger, A., Bohmeyer, W., Kehrt, M., Lange, K., Monte, C., Muller, R.: THz radiometry traceable to SI and suitable detectors. In: 37th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz), pp. 1–2. IEEE (2012)
Steiger, A., Kehrt, M., Monte, C., Muller, R.: Traceable terahertz power measurement from 1 THz to 5 THz. Opt. Express 21(12), 14466–14473 (2013)
Muller, R., Bohmeyer, W., Kehrt, M., Lange, K., Monte, C., Steiger, A.: Novel detectors for traceable THz power measurements. J. Infrared, Millimeter, and Terahertz Waves 35(8), 659–670 (2014)
Muller, R., Gutschwager, B., Hollandt, J.: Characterization of a large-area pyroelectric detector from 300 GHz to 30 THz. J. Infrared, Millimeter, and Terahertz Waves 36(163), 654–661 (2015)
Deng, Y.Q., Sun, Q., Yu, J., Lin, Y., Wang, J.: Broadband high-absorbance coating for terahertz radiometry. Opt. Express 21(5), 5737–5742 (2013)
Deng, Y.Q., Sun, Q., Yu, J.: Broadband black coating for terahertz radiometry. In: 38th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz), pp. 1–2 (2013)
White, M.G., Dowell, M.L., Lehman, J.H.: Traceable terahertz power metrology at NIST. In: 39th International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz), p. 1. (2014)
Steiger, A., Müller, R., Oliva, A., Retal, : Terahertz laser power measurement comparison. IEEE Trans. Terahertz Sci. Technol. 6(5), 664–669 (2016)
Deng, Y.Q., Sun, Q., Yu, J., Xu, N., Lin, Y.D.: Progress of terahertz radiometry and international comparison. Chin. J. Lasers 44(3), 0314001 (2017)
Iida, H., Kinoshita, M., Amemiya, K.: Accurate measurement of absolute terahertz power using broadband calorimeter. J. Infrared Milli Terahz Waves. Published online, 08 March 2018
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Wu, B., Wang, H., Wang, P., Zhang, P., Zhang, W., Ying, C. (2020). Absolute Spectral Responsivity Calibration of Terahertz Detector. In: Peng, Y., Dong, X. (eds) Proceedings of 2018 International Conference on Optoelectronics and Measurement. Lecture Notes in Electrical Engineering, vol 567. Springer, Singapore. https://doi.org/10.1007/978-981-13-8595-7_28
Download citation
DOI: https://doi.org/10.1007/978-981-13-8595-7_28
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-8594-0
Online ISBN: 978-981-13-8595-7
eBook Packages: EngineeringEngineering (R0)