Skip to main content

Absolute Spectral Responsivity Calibration of Terahertz Detector

  • Conference paper
  • First Online:
Proceedings of 2018 International Conference on Optoelectronics and Measurement

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 567))

  • 617 Accesses

Abstract

Calibrating the absolute spectral responsivity is of great importance, because this guides the design and application of terahertz detectors. In this paper, we build a calibration system, and this system can be used to calibrate absolute spectral responsivity of terahertz detectors at a serial of frequencies such as 0.84, 1.63, 2.52, 4.25 THz et al. The key components of the system include a standard terahertz detector and a terahertz gas laser, and other components such as TPX lens and ultrasensitive voltmeter are also included. The calibration system was employed to calibrate a terahertz detector with the model of 12D-3S-VP produced by Gentec Inc., and the absolute spectral responsivity of 193.8 mV/W at 2.52 THz was obtained. The measurement uncertainty is analyzed to be 6.0%. This work not only offers method and system to terahertz detector calibration, but also contributes to high accuracy terahertz power measurement and terahertz device calibration.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Steiger, A., Gutschwager, B., Kehrt, M., Monte, C., Müller, R., Hollandt, J.: Optical methods for power measurement of terahertz radiation. Opt. Express 18(21), 21804–21814 (2010)

    Article  Google Scholar 

  2. Steiger, A., Muller, R.: Traceable calibration of Terahertz detectors. In: Conference on Precision Electromagnetic Measurements (CPEM), pp. 256–257. IEEE (2012)

    Google Scholar 

  3. Steiger, A., Bohmeyer, W., Kehrt, M., Lange, K., Monte, C., Muller, R.: THz radiometry traceable to SI and suitable detectors. In: 37th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz), pp. 1–2. IEEE (2012)

    Google Scholar 

  4. Steiger, A., Kehrt, M., Monte, C., Muller, R.: Traceable terahertz power measurement from 1 THz to 5 THz. Opt. Express 21(12), 14466–14473 (2013)

    Article  Google Scholar 

  5. Muller, R., Bohmeyer, W., Kehrt, M., Lange, K., Monte, C., Steiger, A.: Novel detectors for traceable THz power measurements. J. Infrared, Millimeter, and Terahertz Waves 35(8), 659–670 (2014)

    Article  Google Scholar 

  6. Muller, R., Gutschwager, B., Hollandt, J.: Characterization of a large-area pyroelectric detector from 300 GHz to 30 THz. J. Infrared, Millimeter, and Terahertz Waves 36(163), 654–661 (2015)

    Article  Google Scholar 

  7. Deng, Y.Q., Sun, Q., Yu, J., Lin, Y., Wang, J.: Broadband high-absorbance coating for terahertz radiometry. Opt. Express 21(5), 5737–5742 (2013)

    Article  Google Scholar 

  8. Deng, Y.Q., Sun, Q., Yu, J.: Broadband black coating for terahertz radiometry. In: 38th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz), pp. 1–2 (2013)

    Google Scholar 

  9. White, M.G., Dowell, M.L., Lehman, J.H.: Traceable terahertz power metrology at NIST. In: 39th International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz), p. 1. (2014)

    Google Scholar 

  10. Steiger, A., Müller, R., Oliva, A., Retal, : Terahertz laser power measurement comparison. IEEE Trans. Terahertz Sci. Technol. 6(5), 664–669 (2016)

    Google Scholar 

  11. Deng, Y.Q., Sun, Q., Yu, J., Xu, N., Lin, Y.D.: Progress of terahertz radiometry and international comparison. Chin. J. Lasers 44(3), 0314001 (2017)

    Article  Google Scholar 

  12. Iida, H., Kinoshita, M., Amemiya, K.: Accurate measurement of absolute terahertz power using broadband calorimeter. J. Infrared Milli Terahz Waves. Published online, 08 March 2018

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Bin Wu .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Wu, B., Wang, H., Wang, P., Zhang, P., Zhang, W., Ying, C. (2020). Absolute Spectral Responsivity Calibration of Terahertz Detector. In: Peng, Y., Dong, X. (eds) Proceedings of 2018 International Conference on Optoelectronics and Measurement. Lecture Notes in Electrical Engineering, vol 567. Springer, Singapore. https://doi.org/10.1007/978-981-13-8595-7_28

Download citation

  • DOI: https://doi.org/10.1007/978-981-13-8595-7_28

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-13-8594-0

  • Online ISBN: 978-981-13-8595-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics