Abstract
In this paper, a comparative study of the available important passive islanding techniques used for distributed generation is carried out. The following passive methods are compared and analyzed: under/over voltage, under/over frequency, rate of change of frequency, voltage unbalance and total harmonic distortion, rate of change of active and reactive power, rate of change of phase angle difference, and rate of change of negative- and positive-sequence current methods. The above methods are tested and compared for numerous islanding and non-islanding cases by generating data on the IEEE 399-1997 system through PSCAD/EMTDC software.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Li C, Cao C, Kuang Y, Zeng L, Fang B (2014) A review of islanding detection methods for microgrid. Renew Sustain Energy Rev 35:211–220
Xu W, Zhang G, Li C, Wang W, Wang G, Kliber J (2007) A power line signaling based technique for anti-islanding protection of distributed generators—part i: scheme and analysis. IEEE Trans Power Del 22(3):1758–1766
Chiang WJ, Jou HL, Wu JC, Wu KD, Feng YT (2010) Active islanding detection method for the grid-connected photovoltaic generation system. Electr Power Syst Res 80(4):372–379
IEEE Standard for Interconnecting Distributed Resources With Electric Power Systems, IEEE Standard P1547, June 2003
Zeineldin HH, Kirtley JL (2009) Performance of the OVP/UVP and OFP/UFP method with voltage and frequency dependent loads. IEEE Trans Power Del 24(2):772–778
Ye Z, Kolwalkar A, Zhang Y, Du P, Walling R (2004) Evaluation of anti-islanding schemes based on nondetection zone concept. IEEE Trans Power Electron 19(5):1171–1176
Jang SI, Kim KH (2004) An islanding detection method for distributed generations using voltage unbalance and total harmonic distortion of current. IEEE Trans Power Deliv 19(2):745–752
Danandeh A, Seyedi H, Babaei E (2012) Islanding detection using combined algorithm based on rate of change of reactive power and current THD techniques. In: Proceedings of Asia-Pacific power energy engineering conference, pp 1–4
Samui A, Samantaray SR (2011) Assessment of ROCPAD relay for islanding detection in distributed generation. IEEE Trans Smart Grid 2(2):391–398
Yin J, Diduch CP, Chang L (2008) Islanding detection using proportional power spectral density. IEEE Trans Power Del 23(2):776–784
Bejmert D, Sidhu TS (2014) Investigation into islanding detection with capacitor insertion-based method. IEEE Trans Power Del 29(6):2485–2492
Liu D, Aljankawey A, Diduch C, Chang L, Su J (2015) Passive islanding detection approach based on tracking the frequency-dependent impedance change. IEEE Trans Power Del 30(6):2570–2580
Liu N, Aljankawey AS, Diduch CP, Chang L, Su J, Mao M A new impedance-based approach for passive islanding detection scheme. In: Proceedings of 4th IEEE International Symposium on Power Electronics Distribution Generation Systems, July 2013, pp 1–7
Maheshwari RP, Bhalja BR, Sareen K (2016) Universal islanding detection technique based on rate of change of sequence components of currents for distributed generations. IET Renew Power Gener 10(2):228–237
Samui A, Samantary SR (2013) Wavelet singular entropy-based islanding detection in distributed generation. IEEE Trans. Power Del. 28(1):411–418
Ray PK, Kishor N, Mohanty SR (2012) Islanding and power quality disturbance detection in grid-connected hybrid power system using wavelet and S-transform. IEEE Trans Smart Grid 3(3):1082–1094
Samantaray SR, Babu C, Dash PK (2011) Probabilistic neural network based islanding detection in distributed generation’. Electric Power Comp Syst 39(3):191–203
El-Arroudi K, Joos G, Kamwa I, McGillis DT (2007) Intelligent based approach to islanding detection in distributed generation. IEEE Trans Power Del 22(2):828–835
Patil P, Kulkarni SU (2016) A novel method for islanding detection of distribution system with distributed generator. Int J Sci Res Pub 6(5)
Katiraei F, Iravani MR, Lehn PW, Motors SI (2005) Micro-grid autonomous operation during and subsequent to islanding process. Electronics 20(2):248–257
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Anudeep, B., Verma, A., Nayak, P.K. (2019). Comparative Assessment of Passive Islanding Detection Techniques for Distributed Generations. In: Nath, V., Mandal, J. (eds) Proceedings of the Third International Conference on Microelectronics, Computing and Communication Systems. Lecture Notes in Electrical Engineering, vol 556. Springer, Singapore. https://doi.org/10.1007/978-981-13-7091-5_4
Download citation
DOI: https://doi.org/10.1007/978-981-13-7091-5_4
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-7090-8
Online ISBN: 978-981-13-7091-5
eBook Packages: EngineeringEngineering (R0)