Abstract
Impedance cardiography (ICG) is a non-invasive method to evaluate several cardiodynamic parameters. Pathologic changes in the aorta, like an aortic dissection, will alter the aortic shape as well as the blood flow and, consequently, the impedance cardiogram. This fact distorts the evaluated cardiodynamic parameters on the one hand, and offers the possibility to identify aortic pathologies on the other hand. In order to find an appropriate measurement configuration, in particular for the identification of aortic dissections, a 3D simulation model has been used. Various electrode positions have been investigated to reach a high sensitivity with respect to the discrepancy between the healthy and the dissected case.
Keywords
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Reinbacher-Köstinger, A., et al.: Numerical simulation of conductivity changes in the human thorax. IEEE Trans. Magn. 55, 1–4 (2019)
COMSOL multiphysics v. 5.3. COMSOL AB, Stockholm, Sweden. www.comsol.com
Badeli, V., et al.: Numerical simulation of impedance cardiogram changes in case of chronic aortic dissection, companion paper. In: Proceedings of ICEBI (2019)
Hoetink, A.E., et al.: On the flow dependency of the electrical conductivity of blood. IEEE Trans. Biomed. Eng. 51(7), 1251–1261 (2004)
Cheng, Z., et al.: Analysis of flow patterns in a patient-specific aortic dissection model. J. Biomech. Eng. 132(5), 051007 (2010). https://doi.org/10.1115/1.4000964
Acknowledgment
This work is part of the LEAD project “Mechanics Modeling and Simulation of Aortic Dissection”, funded by Graz University of Technology.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Reinbacher-Köstinger, A., Badeli, V., Melito, G.M., Magele, C., Bíró, O. (2020). Numerical Simulation of Various Electrode Configurations in Impedance Cardiography to Identify Aortic Dissection. In: Bertemes-Filho, P. (eds) 17th International Conference on Electrical Bioimpedance. ICEBI 2019. IFMBE Proceedings, vol 72. Springer, Singapore. https://doi.org/10.1007/978-981-13-3498-6_7
Download citation
DOI: https://doi.org/10.1007/978-981-13-3498-6_7
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-3497-9
Online ISBN: 978-981-13-3498-6
eBook Packages: EngineeringEngineering (R0)