Skip to main content

Integration of Readout of Vertex Detector in Belle II DAQ System

  • Conference paper
  • First Online:
Book cover Proceedings of International Conference on Technology and Instrumentation in Particle Physics 2017 (TIPP 2017)

Abstract

Data acquisition system is a challenge in the Belle II, new generation B factory, experiment starting data taking in 2018, since much higher trigger rate and huge data size must be handled to collect \(8\times 10^{35}\) cm\(^{-2}\)s\(^{-1}\) of peak luminosity from the SuperKEKB accelerator. A beam test of the VXD prototype was carried out in March 2017 at the DESY electron test beam facility as a step of readout integration to the VXD system. During the beam period, we tested three major tasks from DAQ point of view; Event synchronization between the detectors, Stability of high rate performance with online tracking, and establishment of the slow control scheme. In this letter, details of the DESY beam test are discussed, with prospects toward the phase II beam commissioning run in 2018 the phase III physics run.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Abe, T., et al.: Belle II Technical Design Report, arXiv:1011.0352 (2010)

  2. Yamada, S., et al.: Data acquisition system for the Belle II experiment. IEEE Trans. Nucl. Sci. 62, 1175–1180 (2015)

    Article  ADS  Google Scholar 

  3. Suna, D., et al.: Belle2Link: a global data readout and transmission for Belle II experiment at KEK. Phys. Procedia 37, 1933–1939 (2012)

    Article  ADS  Google Scholar 

  4. Higuchi, T., et al.: Modular pipeline readout electronics for the SuperBelle drift chamber. IEEE Trans. Nucl. Sci. 52, 1912–1917 (2005)

    Article  ADS  Google Scholar 

  5. Moser, H., et al.: Author links open the author workspace. The Belle II DEPFET pixel detector. Nucl. Instrum. Methods Phys. Res. A 831, 85–87 (2016). 21

    Article  ADS  Google Scholar 

  6. Itoh, R., et al.: Data flow and high level trigger of Belle II DAQ system. IEEE Trans. Nucl. Sci. 60, 3720–3724 (2013)

    Article  ADS  Google Scholar 

  7. Levit, D., et al.: FPGA based data read-out system of the Belle II pixel detector. IEEE Trans. Nucl. Sci. 62, 1033–1039 (2015)

    Article  ADS  Google Scholar 

  8. Nakao, M., et al.: Minimizing dead time of the Belle II data acquisition system with pipelined trigger flow control. IEEE Trans. Nucl. Sci. 60, 3729–3734 (2013)

    Article  ADS  Google Scholar 

  9. Suzuki, S.Y.: The three-level event building system for the Belle II experiment. IEEE Trans. Nucl. Sci. 62, 1162–1168 (2015)

    Article  ADS  Google Scholar 

  10. Gessler, T., et al.: The ONSEN data reduction system for the Belle II pixel detector, arXiv:1406.4028 (2014)

  11. Thalmeier, R., et al.: The Belle II SVD data readout system. Nucl. Instrum. Methods A845, 633–638 (2017)

    Article  ADS  Google Scholar 

  12. Konno, T., et al.: The slow control and data quality monitoring system for the Belle II experiment. IEEE Trans. Nucl. Sci. 62, 897–902 (2015)

    Article  ADS  Google Scholar 

  13. EPICS-Experimental Physics and Industrial Control System. http://www.aps.anl.gov/epics/

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tomoyuki Konno .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Konno, T. et al. (2018). Integration of Readout of Vertex Detector in Belle II DAQ System. In: Liu, ZA. (eds) Proceedings of International Conference on Technology and Instrumentation in Particle Physics 2017. TIPP 2017. Springer Proceedings in Physics, vol 212. Springer, Singapore. https://doi.org/10.1007/978-981-13-1313-4_13

Download citation

Publish with us

Policies and ethics