Data acquisition system is a challenge in the Belle II, new generation B factory, experiment starting data taking in 2018, since much higher trigger rate and huge data size must be handled to collect \(8\times 10^{35}\) cm\(^{-2}\)s\(^{-1}\) of peak luminosity from the SuperKEKB accelerator. A beam test of the VXD prototype was carried out in March 2017 at the DESY electron test beam facility as a step of readout integration to the VXD system. During the beam period, we tested three major tasks from DAQ point of view; Event synchronization between the detectors, Stability of high rate performance with online tracking, and establishment of the slow control scheme. In this letter, details of the DESY beam test are discussed, with prospects toward the phase II beam commissioning run in 2018 the phase III physics run.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Abe, T., et al.: Belle II Technical Design Report, arXiv:1011.0352 (2010)
Yamada, S., et al.: Data acquisition system for the Belle II experiment. IEEE Trans. Nucl. Sci. 62, 1175–1180 (2015)
Suna, D., et al.: Belle2Link: a global data readout and transmission for Belle II experiment at KEK. Phys. Procedia 37, 1933–1939 (2012)
Higuchi, T., et al.: Modular pipeline readout electronics for the SuperBelle drift chamber. IEEE Trans. Nucl. Sci. 52, 1912–1917 (2005)
Moser, H., et al.: Author links open the author workspace. The Belle II DEPFET pixel detector. Nucl. Instrum. Methods Phys. Res. A 831, 85–87 (2016). 21
Itoh, R., et al.: Data flow and high level trigger of Belle II DAQ system. IEEE Trans. Nucl. Sci. 60, 3720–3724 (2013)
Levit, D., et al.: FPGA based data read-out system of the Belle II pixel detector. IEEE Trans. Nucl. Sci. 62, 1033–1039 (2015)
Nakao, M., et al.: Minimizing dead time of the Belle II data acquisition system with pipelined trigger flow control. IEEE Trans. Nucl. Sci. 60, 3729–3734 (2013)
Suzuki, S.Y.: The three-level event building system for the Belle II experiment. IEEE Trans. Nucl. Sci. 62, 1162–1168 (2015)
Gessler, T., et al.: The ONSEN data reduction system for the Belle II pixel detector, arXiv:1406.4028 (2014)
Thalmeier, R., et al.: The Belle II SVD data readout system. Nucl. Instrum. Methods A845, 633–638 (2017)
Konno, T., et al.: The slow control and data quality monitoring system for the Belle II experiment. IEEE Trans. Nucl. Sci. 62, 897–902 (2015)
EPICS-Experimental Physics and Industrial Control System. http://www.aps.anl.gov/epics/
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Konno, T. et al. (2018). Integration of Readout of Vertex Detector in Belle II DAQ System. In: Liu, ZA. (eds) Proceedings of International Conference on Technology and Instrumentation in Particle Physics 2017. TIPP 2017. Springer Proceedings in Physics, vol 212. Springer, Singapore. https://doi.org/10.1007/978-981-13-1313-4_13
Download citation
DOI: https://doi.org/10.1007/978-981-13-1313-4_13
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-1312-7
Online ISBN: 978-981-13-1313-4
eBook Packages: Physics and AstronomyPhysics and Astronomy (R0)