Skip to main content

Motion Artifact Reduction from Finger Photoplethysmogram Using Discrete Wavelet Transform

  • Conference paper
  • First Online:
Recent Trends in Signal and Image Processing

Part of the book series: Advances in Intelligent Systems and Computing ((AISC,volume 727))

Abstract

In this work, discrete wavelet transform was used to remove the effect of motion artifact on the Photoplethysmogram (PPG) signal obtained at fingertip. Clean PPG signal and motion data (one direction) were collected from 40 healthy volunteers at 14-bit resolution using NI 6009 DAQ card, and synthetic noisy signal was generated by addition. The noisy signal was first decomposed into a specific number of levels to obtain different frequency bands. Then, soft thresholding method was used to remove the noisy components. Different wavelet functions (Daubechies, Symlet, Coiflet) and soft thresholding methods (‘rigrsure,’ ‘heursure,’ ‘sqtwolog,’ etc.) were used to denoise the corrupted PPG signal. A comparative study was made between all of these methods by calculating performance measures such as signal-to-noise ratio improvement, mean square error, and percentage noise retention. The mother wavelet ‘Db6’ and ‘rigrsure’ soft thresholding method showed the best result.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Allen JJ (2007) Photoplethysmography and its application in clinical physiological measurement. Physiol Meas 28(3):1–39

    Article  Google Scholar 

  2. Kyriacou PA (2006) Pulse oximetry in the oesophagus. Physiol Meas 27(1):1–35

    Article  Google Scholar 

  3. Hertzman AB (1938) The blood supply of various skin areas as estimated by the photoelectric plethysmograph. Am J Physiol 124:328–340

    Google Scholar 

  4. Hee X, Goubran RA, Liu XP (2014) Secondary peak detection of PPG signal for continuous cuffless arterial blood pressure measurement. IEEE Trans Instrum Meas 63(6):1431–1439

    Article  Google Scholar 

  5. Gil E, Orini M, Bailon R (2010) Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions. Physiol Meas 31(9):1271–1290

    Article  Google Scholar 

  6. Nakajima K, Tamura T, Miike H (1996) Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique. Med Eng Phys 18(5):365–372 Elsevier

    Article  Google Scholar 

  7. Sweeney KT, Ward TE, MacLoone SF (2012) Artifact removal in physiological signals-practices and possibilities. IEEE Trans Inf Technol Biomed 16(3):488–500

    Article  Google Scholar 

  8. Han H, Kim MJ, Kim J (2007) Development of real time motion artifact reduction algorithm for a wearable photoplethysmography. In: IEEE EMBS conference France, pp 1538–1541

    Google Scholar 

  9. Raguram M, Madhav KV, Krishna EH, Reddy KN, Reddy KA (2011) On the performance of time varying step–size least mean squares (TVS-LMS) adaptive filter for MA reduction from PPG signals. In: ICCSP Conference, pp 431–435

    Google Scholar 

  10. Raguram M, Madhav KV, Krishna EH (2012) A novel approach for motion artifact reduction in PPG signals based on AS-LMS adaptive filter. IEEE Trans Instrum Meas 61(5):1445–1457

    Article  Google Scholar 

  11. Castells F, Laguna P, Sornmo L (2007) Principal component analysis in ECG signal processing. Eurasip J Adv Signal Process 2007(1):98–98

    Google Scholar 

  12. Cho JM, Sung YK, Shin KW (2012) A preliminary study on photoplethysmogram (PPG) signal analysis for reduction of motion artifact in frequency domain. In: IEEE EMBS conference on IECBES, pp 28–33

    Google Scholar 

  13. Wang Q, Yang P (2010) Artifacts reduction based on empirical mode decomposition (EMD) in photoplethysmography for pulse rate detection. In: IEEE EMBC conference, pp 959–962

    Google Scholar 

  14. Pinheiro E, Postolache O, Girao P (2012) Empirical mode decomposition and principal component analysis implementation in processing non-invasive cardiovascular signals. Measurement 45(2):175–181. Elsevier

    Article  Google Scholar 

  15. Lee CM, Zhang YT (2003) Reduction of motion artifacts from photoplethysmographic recordings using a wavelet denoising approach. In: IEEE EMBS Asian-Pacific conference on biomedical engineering, pp 194–195

    Google Scholar 

  16. Raghuram M, Madhav KV, Krishna EH (2010) On the performance of wavelets in reducing motion artifacts from photoplethysmographic signals. In: IEEE international conference on ICBBE, China, pp 121–128

    Google Scholar 

  17. Wavelet toolbox user guide MATLAB®. www.mathworks.com

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Anita Biswas .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Biswas, A., Singha Roy, M., Gupta, R. (2019). Motion Artifact Reduction from Finger Photoplethysmogram Using Discrete Wavelet Transform. In: Bhattacharyya, S., Mukherjee, A., Bhaumik, H., Das, S., Yoshida, K. (eds) Recent Trends in Signal and Image Processing. Advances in Intelligent Systems and Computing, vol 727. Springer, Singapore. https://doi.org/10.1007/978-981-10-8863-6_10

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-8863-6_10

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-8862-9

  • Online ISBN: 978-981-10-8863-6

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics