Abstract
The transformer is one of the most important components in power system network. Because of its relatively simple construction, it is a highly reliable piece of equipment. Keeping design principle in mind the parameter of transformer was obtained by open circuit and short circuit tests, without actually loading the transformer, and these two assessed tests give the test results which are used to determine the equivalent circuit parameters. This paper presents the equivalent parameters from test data and significance H.V. or L.V. side in which the calculation to be performed, and then simulated same thing in MATLAB/Simulink. The comparison of simulated results and experimental results of open circuit and short circuit is shown.
This is a preview of subscription content, log in via an institution.
References
Theraja, B. L., Theraja, A. K., Patel, U. A., Uppal, S. L., Panchal, J. C., Oza, B.,… & Patel, R. M. (2005). A Textbook of Electrical Technology Vol II. Chand & Co., New Delhi.
Ayasun, Saffet, and Chika O. Nwankpa. “Transformer tests using MATLAB/Simulink and their integration into undergraduate electric machinery courses.” Computer Applications in Engineering Education 14.2 (2006): 142–150.
Laughton, Michael A., and Maurice George Say, eds. Electrical engineer’s reference book. Elsevier, 2013.
A. C. Franklin, and D. P. Franklin, The J & P Transformer Books, 11th ed. New Delhi: Aditya Books, 1983.
Song, H., Zhao, F., & He, D. (2012). Simulation Study on Internal Fault of Transformer. Physics Procedia, 25, 459–464.
M. G. Say, The Performance and Design of Alternating Current Machines, 3rd ed. NewDelhi:CBSPublishers, 1983.
Acknowledgements
Special acknowledgments for G.H. Patel College of Engineering and Technology, Vallabh Vidyanagar, India, for letting us to use electrical machine laboratory which helped us to do experiments to find out the parameters of transformer.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Appendix
Appendix
The rating of transformer used for this test has following specification:
1 kVA, 230/115 V single-phase transformer, 50 Hz.
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Upadhyaya, P.N., Makwana, V.H. (2018). To Find Parameters of Transformer Using Open-Circuit and Short-Circuit Tests. In: Kher, R., Gondaliya, D., Bhesaniya, M., Ladid, L., Atiquzzaman, M. (eds) Proceedings of the International Conference on Intelligent Systems and Signal Processing . Advances in Intelligent Systems and Computing, vol 671. Springer, Singapore. https://doi.org/10.1007/978-981-10-6977-2_21
Download citation
DOI: https://doi.org/10.1007/978-981-10-6977-2_21
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-6976-5
Online ISBN: 978-981-10-6977-2
eBook Packages: EngineeringEngineering (R0)