Abstract
Air displacement plethysmography is used to measure body volume. The Bod Pod (COSMED USA Inc., Concord, CA) is an easy-to-use, convenient, non-invasive device that can accommodate a large spectrum of athletic physiques, assessing fat and fat-free mass reliably and accurately. Estimates of body density are in close agreement to those using the hydrostatic weighing technique, with Bod Pod now considered the gold standard for assessment of body density in multi-compartment models. It often underestimates fat mass compared to other physique assessment techniques; however, this may be due to poor standardisation practices. When undertaken in a well-controlled standardised manner, Bod Pod has proven to be an accurate and reliable technique for tracking physique changes over time. It is valuable in large athletes who may be more comfortable undertaking physique assessment via Bod Pod compared to other techniques where reliability in this population might be an issue.
References
Anderson DE (2007) Reliability of air displacement plethysmography. J Strength Cond Res 21:169–172
Ballard TP, Fafara L, Vukovich MD (2004) Comparison of bod pod and DXA in female collegiate athlete. Med Sci Sports Exerc 36(4):731–735
Bentzur KM, Kravitz L, Lockner DW (2008) Evaluation of the BOD POD for estimating percent body fat in collegiate track and field female athletes: a comparison of four methods. J Strength Cond Res 22(6):1985–1991
Brožek J, Grande F, Anderson J, Keys A (1963) Densitometric analysis of body composition: revision of some quantitative assumptions. Annals of the New York Academy of Science 110(1):113–140
Collins AL, McCarthy HD (2003) Evaluation of factors determining the precision of body composition measurements by air displacement plethysmography. Eur J Clin Nutr 57(6):770–776
Collins MA, Millard-Stafford ML, Evans EM, Snow TK, Cureton KJ, Rosskopf LB (2004) Effect of race and musculoskeletal development on the accuracy of air plethysmography. Med Sci Sports Exerc 36(6):1070–1077
Collins MA, Millard-Stafford ML, Sparling PB, Snow TK, Rosskopf LB, Webb SA, Omer J (1999) Evaluation of the bod pod for assessing body fat in collegiate football players. Med Sci Sports Exerc 31(9):1350–1356
COSMED USA (2014) BOD POD gold standard body composition tracking system operators manual–P/N 210–2400, REV-I. Concord, CA
Davis JA, Dorad S, Keays KA, Reigel KA, Valencia KS, Pham PH (2007) Reliability and validity of the lung volume measurement made by the BOD POD body composition system. Clin Physiol Funct Imaging 27(1):42–46
Dempster P, Aitkens S (1995) A new air displacement method for the determination of human body composition. Med Sci Sport Exerc 27(12):1692–1697
Fields DA, Gunatilake R, Kalaitzoglou E (2015) Air displacement plethysmography: cradle to grave. Nutr Clin Pract 30(2):219–226
Fields DA, Higgins PB, Hunter GR (2004) Assessment of body composition by air-displacement plethysmography: influence of body temperature and moisture. Dynamic. Medicine 3(1):3
Fields DA, Hunter GR, Goran MI (2000) Validation of the BOD POD with hydrostatic weighing: influence of body clothing. Int J Obes Relat Metab Disord 24(2):200–205
Fields DA, Wilson GD, Gladden LB, Hunter GR, Pascoe DD, Goran MI (2001) Comparison of the BOD POD with the four-compartment model in adult females. Med Sci Sport Exerc 33(9):1605–1610
Gnaedinger RH, Reineke EP, Pearson AM, Van Huss WD, Wessel JA, Montoye HJ (1963) Determination of body density by air displacement, helium dilution, and underwater weighing. Ann N Y Acad Sci 110(1):96–108
Heiss CJ, Gara N, Novotny D, Heberle H, Morgan L, Stufflebeam J, Fairfield M (2009) Effect of a 1 liter fluid load on body composition measured by air displacement plethysmography and bioelectrical impedance. J Exerc Physiol Online 12(2):1–8
Ludwig UA, Klausman F, Baumann S, Honal M, Hövener JB, König D, Deibert P, Büchert M (2014) Whole-body MRI-based fat quantification: a comparison to air displacement plethysmography. J Magn Reson Imaging 40(6):1437–1444
Millard-Stafford ML, Collins MA, Evans EM, Snow TK, Cureton KJ, Rosskopf LB (2001) Use of air displacement plethysmography for estimating body fat in a four-component model. Med Sci Sports Exerc 33(8):1311–1317
Noreen EE, Lemon PWR (2006) Reliability of air displacement plethysmography in a large, heterogeneous sample. Med Sci Sports Exerc 38(8):1505–1509
Ortiz O, Russell M, Daley TL, Baumgartner R, Waki M, Lichtman S, Wang J, Pierson RNJ, Heymsfield SB (1992) Differences in skeletal muscle and bone mineral mass between black and white females and their relevance to estimates of body composition. Am J Clin Nutr 55(1):8–13
Otterstetter R, Johnson KE, Kiger DL, Agnor SE, Edwards J, Naylor JB, Krone SJ (2013) The effect of acute moderate-intensity exercise on the accuracy of air-displacement plethysmography in young adults. Eur J Clin Nutr 67(10):1092–1094
Peeters MW, Claessens AL (2011) Effect of different swim caps on the assessment of body volume and percentage body fat by air displacement plethysmography. J Sports Sci 29(2):191–196
Siri WE (1956) The gross composition of the body. Adv Biol Med Phys 4:239–280
Tegenkamp MH, Clark RR, Schoeller DA, Landry GL (2011) Effects of covert subject actions on percent body fat by air-displacement plethysmography. J Strength Cond Res 25(7):2010–2017
Tucker LA, Lecheminant J, Bailey BW (2014) Test-retest reliability of the bod pod: the effect of multiple assessments. Percept Mot Skills 118(2):563–570
Utter AC, Goss FL, Swan PD, Harris GS, Robertson RJ, Trone GA (2003) Evaluation of air displacement for assessing body composition of collegiate wrestlers. Medicine Science and Sports Exercise 35(3):500–505
Vescovi JD, Zimmerman SL, Miller WC, Fernhall B (2002) Effects of clothing on accuracy and reliability of air displacement plethysmography. Medicine Science Sport and Exercise 34(2):282–285
Vescovi JD, Zimmerman SL, Miller WC, Hildebrandt L, Hammer RL, Fernhal lB (2001) Evaluation of the BOD POD for estimating percentage body fat in a heterogeneous group of adult humans. Eur J Appl Physiol 85(3-4):326–332
Wells JC, Fuller NJ (2001) Precision of measurement and body size in whole-body air-displacement plethysmography. International Journal of Obesity Related Metabolic Disorders 25(1):1161–1167
Weyers AM, Mazzetti SA, Love DM, Gómez AL, Kraemer WJ, Volek JS (2002) Comparison of methods for assessing body composition changes during weight loss. Med Sci Sports Exerc 34(3):497–502
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd.
About this chapter
Cite this chapter
Shaw, G., Kerr, A. (2018). Non-imaging Method: Air Displacement Plethysmography (Bod Pod). In: Hume, P., Kerr, D., Ackland, T. (eds) Best Practice Protocols for Physique Assessment in Sport. Springer, Singapore. https://doi.org/10.1007/978-981-10-5418-1_8
Download citation
DOI: https://doi.org/10.1007/978-981-10-5418-1_8
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-5417-4
Online ISBN: 978-981-10-5418-1
eBook Packages: MedicineMedicine (R0)