Abstract

In this paper, methodology for finding optimum composition of binary mixture (R290/R1270) for Solar-Assisted Heat Pump (Direct Expansion) is framed. Experiments are conducted on DX-SAHP by using R22 under the metrological condition of Calicut, India. Properties of binary mixture such as vapour pressure, liquid density for mass percentage of R1270 ranging from 0 to 50% is taken from REFPROP 11® software. Artificial Neural Network (ANN) is integrated with Genetic algorithm (GA) in MATLAB 7.7.0® to obtain optimum composition of binary mixture, where maximized EPR (Energy Performance Ratio) and minimized cost of refrigerant are two objective functions. The result shows that, the optimum compositions of binary mixture are 70% of R290 with 30% of R1270. Unique feature of this study is that, ANN integrated with GA technique can be used to find best optimum composition of alternative refrigerant mixture by mass percentage for any given system, provided experimental data of that system should be available for R22 or any other refrigerant.

Keywords

Direct expansion solar-assisted heap pump ANN GA Alternative refrigerant Optimize mixture composition 

References

  1. 1.
    United Nations Environmental Programme, Montreal Protocol on Substances that Deplete the Ozone Layer, Final act, United Nations, New York (1987)Google Scholar
  2. 2.
    Global Environmental Change Report, A brief analysis of the Kyoto protocol, 9(24) (1997)Google Scholar
  3. 3.
    Directive 2006/40/EC of the European Parliament and of the Council. Off. J. Eur. Union, 2006 (14.6.2006)Google Scholar
  4. 4.
    A. Cavallini, Working fluids for mechanical refrigeration. Int. J. Refrig. 19, 485–496 (1996)CrossRefGoogle Scholar
  5. 5.
    K.-J. Park, Y.-B. Shim, D. Jung, Performance of R433A for replacing HCFC22 used in residential air-conditioners and heat pumps. Appl. Energy 85, 896–900 (2007)CrossRefGoogle Scholar
  6. 6.
    K.-J. Park, Y.-B. Shim, D. Jung, Experimental performance of R432A to replace R22 in residential air-conditioners and heat pumps. Appl. Therm. Eng. 29, 597–600 (2009)CrossRefGoogle Scholar
  7. 7.
    K.-J. Park, D. Jung, Performance of heat pumps charged with R170/R290 mixture. Appl. Energy 86, 2598–2603 (2009)Google Scholar
  8. 8.
    B. Purkayastha, P.K. Bansan, An experimental study on HC290 and a commercial liquefied petroleum gas (LPG) mix as suitable replacements for HCFC22. Int. J. Refrig. 21, 3–17 (1997)Google Scholar
  9. 9.
    H.Z. Abou-Ziyan, M.F. Ahmed, M.N. Metwally, H.M.A. El-Hameed, Solar assisted R22 and R134a heat pump systems for low temperature applications. Energy Convers. Eng. Conf. 2, 787–792 (1996)Google Scholar
  10. 10.
    M. Mohanraj, S. Jayaraj, C. Muraleedharan, A comparison of the performance of a direct expansion solar assisted heat pump working with R22 and a mixture of R407C liquefied petroleum gas. J. Power Energy 223, 821 (2009)Google Scholar
  11. 11.
    X.D. Wang, L. Zhao, J.L. Wang, W.Z. Zhang, X.Z. Zhao, W. Wu, Performance evaluation of a low-temperature solar Rankine cycle system utilizing R245fa. Solar Energy 84(3), 353–364 (2010)Google Scholar

Copyright information

© Springer Nature Singapore Pte Ltd. 2018

Authors and Affiliations

  • K. Vinoth Kumar
    • 1
  • Lokesh Paradeshi
    • 1
  • M. Srinivas
    • 1
  • S. Jayaraj
    • 1
  1. 1.Department of Mechanical EngineeringNational Institute of TechnologyCalicutIndia