Abstract
In recent years, atmospheric micro-plasma has various applications in the biomedical field, including blood coagulation, tissue sterilization, wound care etc. However, the mechanisms of atmospheric micro-plasma, mainly through particle excited state, and some of the gas molecules enter into the target is still controversy. In many experiments, micro-plasma exposure into cells medium, are reflected in the amount of excess plasma species, so that the cells will accelerate the process of apoptosis, and even necrosis. Therefore diagnosis plasma parameters is necessary, in this study the distance from the plasma jet to the target, different kind of gas addition, or various kind of solution will be applied. The purpose of this research is to explore the interaction of plasma parameter to the solution compositions for further optimal applications in wound care or cancer treatment.
Keywords
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Iza F, Kim GJ, Lee SM, Lee JK, Walsh JL, Zhang YT, Kong MG (2008) Microplasmas: sources, particle kinetics, and biomedical applications. Plasma Processes Polym 5(4):322–344
Weng CC, Wu YT, Liao JD, Kao CY, Chao CC, Chang JE, Hsu BW (2009) Inactivation of bacteria by a mixed argon and oxygen micro-plasma as a function of exposure time. Int J Radiat Biol 85(4):362–368
Ermolaeva SA, Varfolomeev AF, Chernukha MY, Yurov DS, Vasiliev MM, Kaminskaya AA, Moisenovich MM, Romanova JM, Murashev AN, Selezneva II et al (2011) Bactericidal effects of non-thermal argon plasma in vitro, in biofilms and in the animal model of infected wounds. J Med Microbiol 60(1):75–83
Ehlbeck J, Schnabel U, Polak M, Winter J, von Woedtke T, Brandenburg R, von dem Hagen T, Weltmann KD (2011) Low temperature atmospheric pressure plasma sources for microbial decontamination. J Phys D-Appl Phys 44(1):013002
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Hien, N.T.M., Linh, H.Q., Thuy, N.N.S., Der, L.J. (2018). Effect of Micro-plasma Parameters to Different Kind of Solutions for Biomedical Applications. In: Vo Van, T., Nguyen Le, T., Nguyen Duc, T. (eds) 6th International Conference on the Development of Biomedical Engineering in Vietnam (BME6) . BME 2017. IFMBE Proceedings, vol 63. Springer, Singapore. https://doi.org/10.1007/978-981-10-4361-1_43
Download citation
DOI: https://doi.org/10.1007/978-981-10-4361-1_43
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-4360-4
Online ISBN: 978-981-10-4361-1
eBook Packages: EngineeringEngineering (R0)