In this paper, the selection of witness points in quality plan, key points in equipment supervision as well as supervision risks have been investigated through the supervision planning of EDG used in Hualong #1 nuclear unit, the third generation with proprietary intellectual property right of China, adhering to the principles of ‘Key supervision for key equipment’ and ‘Enhanced control on weak points’. The aim of this work is to enhance the efficiency and improve the quality control in supervision. And this paper can be used as a beneficial reference for the improvement of supervision efficiency and quality management of NPS.