Advertisement

The Remote-Field Eddy Current Testing

  • Songling HuangEmail author
  • Shen Wang
Chapter
  • 957 Downloads
Part of the Springer Series in Measurement Science and Technology book series (SSMST)

Abstract

The remote-field eddy current (RFEC) testing is a special eddy current testing technology that utilizes the characteristics of the remote-field region of the eddy current to detect the defects and was applied in the inner inspection of small caliber pipeline first.

Keywords

Eddy Current Pipe Wall Phase Signal Defect Signal Flux Line 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 1.
    Schmidt, T.R.: The casing inspection tool - an instrument for the in-situ detection of external casing corrosion in oil wells. Corrosion 7, 81–85 (1961)Google Scholar
  2. 2.
    Schmidt, T.R.: Remote field eddy current inspection technique. 42(2), 225–230 (1984)Google Scholar
  3. 3.
    Schmidt, T.R.: The remote field eddy current inspection technique. Mater. Eval. 2, 225–230 (1984)Google Scholar
  4. 4.
    Lord, W., et al.: Finite element study of the remote field eddy current phenomenon. IEEE Trans. Magn. 24(1), 435–438 (1987)Google Scholar
  5. 5.
    Hoshikawa, H., et al.: Characteristics of remote-field eddy current technique. Mater Eval. 47(1), 93–97 (1989)Google Scholar
  6. 6.
    Sun, Y.-S.: Finite-element study of diffusion energy flow in low-frequency eddy current fields. Mater. Eval. 47(1), 87–92 (1989)Google Scholar
  7. 7.
    Atherton, D.L., Sullivan, S.: Remote-field through-wall electromagnetic inspection technique for pressure tubes. Mater. Eval. 44(13), 1544–1550 (1986)Google Scholar
  8. 8.
    Teitsma, A.: Remote field eddy current inspection of unpiggable pipelines. Final report, GTI project 30801—02 (2004)Google Scholar
  9. 9.
    Sun, Y.S., Roach, D., Zhu, H.: New advances in detecting cracks in raised-head fastener holes using rotational remote field eddy current technique. In: ASNT Fall Conference, Columbus, OH (2005)Google Scholar
  10. 10.
    Atherton, D.L., Morton, K.L.: Inspection of prestressed concrete pressure pipe. Rev. Prog. QNDE 19, 709–1715 (2000)Google Scholar
  11. 11.
    Yusa, N., Demachi, K., Chen, Z.M.: An RFEC probe with a superconductor shield. Rev. Prog. QNDE 23, 405–412 (2004)Google Scholar

Copyright information

© Tsinghua University Press and Springer Science+Business Media Singapore 2016

Authors and Affiliations

  1. 1.Department of Electrical EngineeringTsinghua UniversityBeijingChina

Personalised recommendations