Abstract
Some experiments were designed to check the effects of monitor parameters such as color temperature, brightness, and gamma value on soft proofing. We have two illuminant levels D50 and D65, two brightness levels 100 and 120, and two gamma value levels 1.8 and 2.2 to be chosen in constructing international color consortium profiles (ICC profiles). Then, soft proofing simulation experiment was executed. Comparisons were made between the results of soft proofing and printer to obtain the optimum parameters. Results were evaluated by color difference analysis, individual component analysis of \( \Delta L^{*} \),\( \Delta a^{*} \), and \( \Delta b^{*} \) values, and psychophysical experiments. Experiments show that the performance of soft proofing varies a lot with different parameters. And it can get a better performance with the appropriate parameters. At last, the optimal parameter combination was obtained.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Tian, Q. (2004). The influence of gamma value on display. Printing Engineering, 43–44
Marin, J. (2011). Calibration and profiling for soft proofing. Printing Industries of America
Hong, L., & Jiang, X.-z. (2012). Research of liquid crystal display color management standardization: Printing quality and standardization (pp. 29–34, p. 6).
Fleming III, P. D., Sharma, A. Color management with ICC profiles: Can’t live without it so learn to live with it (p. 19).
Liang, H. (2013). Quality evaluation of LCD monitor characteristic profile: Printing quality and standardization (pp. 38–43, p. 6).
Zhao, B., Zheng, Y. –l. (2012). Evaluation on the performance of color-difference formula under various viewing conditions: China printing and packaging study (Vol. 04 24–28, p. 5).
Fleming III, P. D., Chovancova, V., Starr, B., Sharma, A. CRT and LCD Monitors for Soft Proofing (p. 28).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer Science+Business Media Singapore
About this paper
Cite this paper
Zhou, H., Lin, M. (2016). Parameter Optimization Experiment for Soft Proofing. In: Ouyang, Y., Xu, M., Yang, L., Ouyang, Y. (eds) Advanced Graphic Communications, Packaging Technology and Materials. Lecture Notes in Electrical Engineering, vol 369. Springer, Singapore. https://doi.org/10.1007/978-981-10-0072-0_10
Download citation
DOI: https://doi.org/10.1007/978-981-10-0072-0_10
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-0070-6
Online ISBN: 978-981-10-0072-0
eBook Packages: EngineeringEngineering (R0)