Skip to main content

Transmission of Measuring Signals and Power Supply of Remote Sensors

  • Conference paper
  • First Online:
Nanotechnology in the Security Systems

Abstract

The invariant relationship between the sets of load conductivity values at the output of the two or three wire DC communication line and the corresponding conductivity values at the input of this line is shown. This relationship does not depend on parameters of communication line, accuracy of measuring devices. It allows transmitting signals over the two and three wire communication lines. Also, it is shown that in the two wire DC power supply line with loss resistances it is possible to form the output characteristic of this line, as the source of constant load current, by negative value of one of lateral resistance.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Ovchinnikov VV (2005) RU Patent 2,250,566, 20 Apr 2005

    Google Scholar 

  2. Ovchinnikov VV (2011) RU Patent 2,435,303, 27 Nov 2011

    Google Scholar 

  3. Orischenko VN (1995) RU Patent 2,050,039, 10 Dec 1995

    Google Scholar 

  4. Ovchinnikov VV (2011) US Patent 8,446,977, 12 May 2011

    Google Scholar 

  5. Penin A (2009) The invariant properties of two-port circuits. World Acad Sci Eng Technol 28. http://waset.org/publications/5517/the-invariant-properties-of-two-port-circuits. Accessed 27 Nov 2013

  6. Penin A (2012) Invariant properties of cascaded six-pole networks. Int J Circuits Syst Signal Process 6(5). http://www.naun.org/main/NAUN/circuitssystemssignal/16-059.pdf. Accessed 27 Nov 2013

  7. Penin A, Sidorenko A (2011) MD Patent 536, 12 Dec 2011. http://www.agepi.md/pdf/publishing/bopi/bopi-07-2012/BOPI-Inven-07-2012.pdf

  8. Penin A, Sidorenko A (2012) MD Patent 543, 13 Jan 2012. http://www.agepi.md/pdf/publishing/bopi/bopi-08-2012/BOPI-Inven-08-2012.pdf

  9. Penin A, Sidorenko A (2013) MD Patent 692, 13 Feb 2013. http://www.agepi.md/pdf/publishing/bopi/bopi-10-2013/BOPI-Inven-10-2013.pdf

  10. Penin A (2008) Determination of regimes of the equivalent generator based on projective geometry: the generalized equivalent generator. World Acad Sci Eng Technol 22. http://www.waset.org/journals/waset/v22/v22-142.pdf. Accessed 27 Nov 2013

  11. Penin A, Sidorenko A (2013) MD Application, s2013 0169, 15 Oct 2013

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. Penin .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer Science+Business Media Dordrecht

About this paper

Cite this paper

Penin, A., Sidorenko, A. (2015). Transmission of Measuring Signals and Power Supply of Remote Sensors. In: Bonča, J., Kruchinin, S. (eds) Nanotechnology in the Security Systems. NATO Science for Peace and Security Series C: Environmental Security. Springer, Dordrecht. https://doi.org/10.1007/978-94-017-9005-5_23

Download citation

Publish with us

Policies and ethics