Skip to main content

Low Cost Lageos Ranging System

  • Chapter
Time and the Earth’s Rotation

Part of the book series: International Astronomical Union ((IAUS,volume 82))

  • 102 Accesses

Abstract

This paper describes a Lageos laser ranging station design based on single photoelectron detection which could be used to monitor polar motion at all periods, and short-period UT1 variations with high accuracy and at moderately low cost. No comparison has been made with the costs of long baseline radio interferometry (LBI) stations, since the establishment and operation of basic international networks using both approaches seems scientifically well justified. Both LBI and lunar laser ranging results will determine intermediate and long-period UT1 variations and nutation. The LAGEOS laser ranging station design suggested here is similar to the design used in the high-mobility LAGEOS ranging station now being constructed by the University of Texas. It has been shown that 30 cm diameter transmit/receive optics with 10 arc second pointing accuracy and 50 milliwatt average laser power output are usually sufficient to give 70 signal counts in a three minute averaging time, even at 20° elevation angle. Lasers having the desired power at 530 nm wavelength with 10 pps repetition rate and 3 ns pulse length are now reported to be commercially available at moderate cost. The resulting range accuracy for normal points corresponding to the three minute averaging time is three cm, including allowances for absolute calibration of the system, atmospheric refraction correction uncertainties, and Earth tide uncertainties. Much of the pulse-timing electronics needed is commercially available, and many time and latitude stations already have good epoch determination systems. The ten arc second pointing requirement for a 30 cm diameter beam seems considerably easier to meet than the optical requirements for classical observing techniques. A simple beam director with flat mirrors appears quite feasible, with inexpensive encoders on each axis for minicomputer control if desired. A number of special features of the University of Texas high-mobility station would not be needed for a fixed station.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1979 IAU

About this chapter

Cite this chapter

Bender, P.L., Silverberg, E.C. (1979). Low Cost Lageos Ranging System. In: McCarthy, D.D., Pilkington, J.D.H. (eds) Time and the Earth’s Rotation. International Astronomical Union, vol 82. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-9368-6_42

Download citation

  • DOI: https://doi.org/10.1007/978-94-009-9368-6_42

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-90-277-0893-9

  • Online ISBN: 978-94-009-9368-6

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics