Abstract
Cardiotomy suction is generally recognized to be a traumatic part of the cardiopulmonary bypass procedure. Yet the severity of the blood cell damage generated by suction is not widely appreciated, and very little effort has been made to improve this part of the system.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Wright, G. (1976). L’aggrégation cellulaire au cours d’une circulation extracorporelle. Les Cahiers du Cercle d’Etude de la Circulation Extracorporelle, 6, 27
Wright, G. (1977). The avoidance of blood cell aggregation during extracorporeal circulation for open-heart surgery. Proc. Eur. Soc. Artif. Intern. Organs, 3, 102
Wright, G. and Sanderson, J. M. (1976). Cellular aggregation and destruction during blood circulation and oxygenation. Thorax, 31, 405
Swank, R. L., Roth, J. G. and Jansen, J. (1964). Screen filtration pressure method and adhesiveness and aggregation of blood cells. J. Appl. Physiol., 19, 340
Crosby, W. H. and Furth, F. W. (1956). A modification of the benzidine method for measurement of haemoglobin in plasma and urine. Blood, 11, 380
Koller, T. and Hawrylenko, A. (1967). Contribution to the in vitro testing of pumps for extracorporeal circulation. J. Thorac. Cardiovasc. Surg., 54, 22
Wielgorski, J. W., Cross, D. E. and Nevadike, E. V. O. (1975). The effects of subatmospheric pressure on the haemolysis of blood. J. Biomech., 8, 321
Bernstein, E. F., Marzec, V. and Johnston, G. G. (1977). Structural correlates of platelet functional damage by physical forces. Trans. Am. Soc. Artif. Intern. Organs, 23, 617
Brown, C. H., Lemuth, R. F., Heliums, J. D., Leverett, J. B. and Alfrey, C. P. (1975). Response of human platelets to shear stress. Trans. Am. Soc. Artif. Intern. Organs, 21, 35
Colantuoni, G., Heliums, J. D., Moake, J. L. and Alfrey, C. P. (1977). The response of human platelets to shear stress at short exposure time. Trans. Am. Soc. Artif. Intern. Organs, 23, 626
Goldsmith, H. L. (1974). The effects of flow and fluid mechanical stress on red cells and platelets. Trans. Am. Soc. Artif. Intern. Organs, 20, 21
Hung, T. C., Hochmuth, R. M., Joist, J. H. and Sutera, S. P. (1976). Shear-induced aggregation and lysis of platelets. Trans. Am. Soc. Artif. Intern. Organs, 22, 285
Johnston, G. G., Marzec, V. and Bernstein, E. F. (1975). Effects of surface injury and shear stress on platelet aggregation and serotonin release. Trans. Am. Soc. Artif. Intern. Organs, 21, 413
Nevaril, C. G., Lynch, E. C., Alfrey, C. P. and Heliums, J. D. (1968). Erythrocyte damage and destruction induced by shearing stress. J. Lab. Clin. Med., 71, 784
Schlichting, H. (1960). Boundary Layer Theory, 4th Edn. (New York: McGraw-Hill)
McDonald, D. A. (1974). Blood Flow in Arteries, 2nd Edn. (London: Edward Arnold)
Wright, G. and Sanderson, J. M. (1979). Cellular aggregation and trauma in cardio-tomy suction systems. Thorax, 34, 621
Barthelemy, R., Vives, M., Couzy, H., Morucci, J. P., Puel, P. and Enjalbert, A. (1978). Dispositif de controle automatique des aspirations chirurgicales en chirurgie cardiaque. Med. Biol. Eng. Comp., 16, 165
ten Duis, H. J., de Jong, J. C. F., van Asseldonk, A. G. M., Smit Sibinga, C. T. and Wildevuur, C. R. H. (1978). Improved hemocompatibility in open heart surgery. Trans. Am. Soc. Artif. Intern. Organs, 24, 656
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1981 MTP Press Limited
About this chapter
Cite this chapter
Wright, G. (1981). Haematological effects of cardiotomy suction. In: Longmore, D.B. (eds) Towards Safer Cardiac Surgery. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-8048-8_22
Download citation
DOI: https://doi.org/10.1007/978-94-009-8048-8_22
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-009-8050-1
Online ISBN: 978-94-009-8048-8
eBook Packages: Springer Book Archive