Abstract
For the first few years after the introduction of contrast echocardiography by Gramiak, its use was limited to structure identification and shunt detection. In 1974, Kerber reported the use of an ultrasonic contrast method in the diagnosis of valvular regurgitation and intracardiac shunts [1]. He noticed contrast appearing in the left atrium after left ventricular injection in 14 out of 16 patients with mitral regurgitation, and in the left ventricle after aortic root injections in 13 out of 16 patients with aortic regurgitation. Valvular regurgitation as low as 10%, according to angiographic calculations, was detected by this method. One false positive study due to catheter-induced mitral regurgitation was noted. The authors concluded that M-mode ultrasonic monitoring of catheter injections distal to a regurgitant valve is a sensitive and specific — though qualitative — technique for detecting valvular regurgitation. Other laboratories, including our own, have confirmed that intracardiac injections during catheterization can be monitored by echocardiography and that this is a sensitive method for the detection of valvular regurgitation. Little further work has been reported in this area, and this invasive technique probably has only limited applications in the occasional patient where there is a strong contraindication to the use of ionizing radiation, for example in early pregnancy [2].
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Kerber RE, JM Kioschos, RM Lauer: Use of an ultrasonic contrast method in the diagnosis of valvular regurgitation and intracardiac shunts. Am J Cardiol 34:722, 1974.
Meltzer RS, PW Serruys, J McGhie, PG Hugenholtz, J Roelandt: Cardiac catheterization under echocardiographic control in a pregnant woman. Am J Med 71:481, 1981.
Lieppe W, VS Behar, R Scallion, JA Kisslo: Detection of tricuspid regurgitation with two-dimensional echocardiography and peripheral vein injections. Circulation 57:128, 1978.
Kisslo JA: Usefulness of M-mode and cross-sectional echocardiography for analysis of right-sided heart disease. In: Echocardiology (Lancee, CT, ed.), pp 37–47, Martinus Nijhoff, The Hague, 1979.
Wise NK, S Myers, JA Stewart, R Waugh, T Fraker, J Kisslo: Echo inferior venacavography: a technique for study of right sided heart disease. Circulation 59-60(suppl II): 2–202, 1979.
Meltzer RS, DCA van Hoogenhuyze, PW Serruys, MMP Haalebos, PG Hugenholtz, J Roelandt: The diagnosis of tricuspid regurgitation by contrast echocardiography. Circulation 63:1093, 1981.
Meltzer RS, C Meltzer, J Roelandt: Sector scanning views in echocardiography: a systematic approach. Europ Heart J 1:379, 1980.
Meltzer RS, PW Serruys, PG Hugenholtz, J Roelandt: Intravenous carbon dioxide as an echocardiographic contrast agent. J Clin Ultrasound 1:127, 1981.
Pepine CJ, WW Nichols, JH Selby: Diagnostic tests for tricuspid insufficiency: How good? Cath & Cardiovasc Diagnosis 5:1, 1979.
Simon R, H Oelert, HG Borst, PR Lichtlen: Influence of mitral valve surgery on tricuspid incompetence concomitant with mitral valve disease. Circulation 62(suppl I): 1–152, 1980.
Fantini F, A Magherini: Detection of tricuspid regurgitation with pulsed Doppler echocardiography. In: Echocardiology (Lancée CT, ed.), pp 233-235, Martinus Nijhoff, 1979.
Gullace G, M Savoia, V Locatelli, F Schubert, C Ranzi: Evaluation of linear contrast echo on pulmonary valve echogram. International Meeting on Bidimen-sional Echocardiography, Milan, 1980, pp 72-73 (abstract).
Meltzer RS, OEH Sartorius, CT Lancée, PW Serruys, PD Verdouw, C Essed, J Roelandt: Transmission of echocardiographic contrast through the lungs. Ultrasound in Medicine and Biology 7:377, 1981.
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1982 Martinus Nijhoff Publishers
About this chapter
Cite this chapter
Meltzer, R.S., Serruys, P.W., Roelandt, J. (1982). Contrast Echocardiography in Valvular Regurgitation. In: Meltzer, R.S., Roelandt, J. (eds) Contrast Echocardiography. Developments in Cardiovascular Medicine, vol 15. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-7470-8_18
Download citation
DOI: https://doi.org/10.1007/978-94-009-7470-8_18
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-009-7472-2
Online ISBN: 978-94-009-7470-8
eBook Packages: Springer Book Archive