Abstract
Years ago Enoch et al. showed a decay in sensitivity in time in the visual field of patients with active optic nerve disease, with the Flashing Repeat Static Test (FRST). Recently, Drance and Heijl found, with a different technique, similar changes in open angle glaucoma patients. In this paper results are presented taken from an additional group of 10 open angle glaucoma patients, examined with the FRST. No significant decrease in sensitivity in time was found. Tentative explanations for the discrepancy in results are provided. It is concluded that functional responses of patients with open angle glaucoma are different from those of patients with optic nerve disease.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Campos, E. C., Enoch, J. M., Fitzgerald, C. R. and Benedetto, M. D. A simple psychophysical technique provides early diagnosis in optic neuritis. Doc. Ophthalmol. 49: 325 (1980).
Drance, S. and Heijl, A. Personal communication (1980).
Enoch, J. M. Quantitative layer-by-layer perimetry. Invest. Ophthalmol. and Visual Sci. 17: 208 (1978).
Enoch, J. M. and Campos, E. C. Analysis of patients with open angle glaucoma using perimetric techniques reflecting receptive field-like properties. Doc. Ophthalmol. Proc. Series 19: 137 (1979).
Enoch, J. M. and Campos, E. C. New quantitative perimetric tests designed to evaluate receptive field-like properties in diseases of the retina and the optic nerve. In: Electrophysiology and Phychophysic: Their Use in Ophthalmic Diagnosis. Int. Ophthalmol. Clinics 20: 83 (1980).
Enoch, J. M., Campos, E. C. and Bedell, H. E. Visual resolution in a patient exhibiting a visual fatigue or saturation like effect. Arch. Ophthalmol. 97: 76 (1979).
Enoch, J. M., Campos, E. C., Greer, m. and Trobe, J. Measurement of visual resolution at high luminance levels in patients with possible demyelinating disease. Int. Ophthalmol. 1: 99 (1979).
Enoch, J. M., Fitzberald, C. R. and Campos, E. C. Quantitative layer-by-layer perimetry. An extended analysis. Grune and Stratton, New York (1980).
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 1983 Dr W. Junk Publishers, The Hague
About this chapter
Cite this chapter
Campos, E.C., Bellei, S. (1983). Constancy of Sensitivity in Time in Patients with Open Angle Glaucoma: Further Results. In: Greve, E.L., Heijl, A. (eds) Fifth International Visual Field Symposium. Documenta Ophthalmologica Proceedings Series, vol 35. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-7272-8_18
Download citation
DOI: https://doi.org/10.1007/978-94-009-7272-8_18
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-009-7274-2
Online ISBN: 978-94-009-7272-8
eBook Packages: Springer Book Archive