Abstract
The production of images by the use of neutrons having energies in the resonance region is described. Two-dimensional position-sensitive neutron detectors are used to produce transmission images using neutron time-of-flight techniques at the National Bureau of Standards’ electron linac facility. Two types of detectors are described. The first is a crossed-wire proportional counter using 3He as the neutron-sensitive component. The second type utilizes a multichannel plate electron multiplier and a resistive anode readout. A lithium glass scintillator is the neutron-sensitive component in the latter detector. Resonance neutron radiography, using these detectors, has the capability of producing images with isotopic and chemical element discrimination in a complex matrix with a resolution of l mm or better.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Schrack, R.A., Behrens, J.W., Johnson, R., Bowman, C.D., “Resonance neutron radiography using an electron linac,” IEEE Trans, on Nucl. Sci. NS-28 2 (1981) 1640.
Behrens, J.W., Schrack, R.A., Bowman, C.D., “Non-destructive examination of a defective silver braze using resonance neutron radiography,” Nucl. Tech. 511 (1980) 78.
Kopp, M.K., Behrens, J.W., Meacham, M.A., Williams, J.A., Development of proportional counter cameras for neutron imaging with 1-mm resolution, NBSIR-81–2362.
Yin, L.I., Trombka, J.I., Seltzer, S.M., “A small rugged imaging x-ray spectrometer: a Lixiscope with good energy resolution,” Nucl. Inst. & Meth. 172 (1980) 471.
Wiza, J.L., Henkel, P.R., Roy, R.L., “Improved microchannel plate performance with a resistive anode encoder,” Rev. Sci. Inst. 48 9 (1977) 1217.
Lampt0n, M., Carlson, C.W., “Low-distortion resistive anodes for two- dimensional position sensitive MCP systems,” Rev. Sci. Inst. 50 9 (1979) 1093.
Surface Science Laboratories, Inc., 4151 Middlefield Road, Palo Alto, CA 94303.
Strauss,M.G., Brenner, R., Lynch, F.J., Morgan, C.B., “2-D position- sensitive scintillation detector for neutrons,” IEEE Trans, on Nucl. Sci. NS-28 1 (1981) 800.
New slow neutron detector system at UK Rutherford and Appleton Laboratories, European Scientific Notes, Office of Naval Research, London, ESN 35–7 (1981) 284.
Lampton, M., “The microchannel image intensifier,” Sci. Amer. 245 5 (1981) 62.
Bollinger, L.M., Thomas, G.E., Ginther, R.J., “Neutron detection with glass scintillators,” Nucl. Inst. & Meth. 17 (1962) 97.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1983 ECSC, EEC, EAEC, Brussels and Luxembourg
About this paper
Cite this paper
Schrack, R.A., Behrens, J.W., Johnson, R.G., Bowman, C.D. (1983). Resonance Neutron Radiography. In: Barton, J.P., von der Hardt, P. (eds) Neutron Radiography. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-7043-4_61
Download citation
DOI: https://doi.org/10.1007/978-94-009-7043-4_61
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-009-7045-8
Online ISBN: 978-94-009-7043-4
eBook Packages: Springer Book Archive