How to assess the immediate results of PTCA. Should we use pressure gradient, flow reserve or minimal luminal cross-sectional area?

  • Patrick W. Serruys
  • F. Zijlstra
  • Y. Juillière
  • P. J. De Feyter
  • M. Vd Brand
  • H. Suryapranata
  • J. H. C. Reiber
Part of the Developments in Cardiovascular Medicine book series (DICM, volume 87)

Summary

Intracoronary blood flow velocity measurements with a Doppler probe, and the radiographic assessment of myocardial perfusion with contrast media have previously been used to investigate regional coronary flow reserve. We have applied both techniques in the same patients to measure the immediate improvement in coronary flow reserve as a result of angioplasty. In a group of 13 consecutive patients with a single proximal stenosis, coronary flow reserve was measured pre- and post-angioplasty by digital subtraction cineangiography, while Doppler measurements before and after papaverine were obtained pre- and post-angioplasty in the proximal part of the stenotic vessel. As a result of the angioplasty, coronary flow reserve measured with the radiographic technique (mean ± s.d.) increased from 1.1. ± 0.4 to 2.2 ± 0.4 (p < 0.001), while coronary flow reserve measured with the Doppler probe (mean ± s.d.) increased from 1.2 ± 0.3 to 2.4 ± 0.4 (p < 0.001). Pharmacologically induced hyperemia measured with the radiographic technique and with the Doppler probe were linearly related (r = 0.91 with an SEE = 0.3); this excellent relation confirmed the reliability of the intracoronary measurements. Using these two independent techniques coronary flow reserve immediately after angioplasty was found to be substantially improved but still abnormal. In a more recent study, we selected 18 patients without angina and with normal exercise thallium scintigraphy 5 months after successful percutaneous transluminal coronary angioplasty. We compared their coronary flow reserve with the flow reserve of 24 patients with angiographically normal coronary arteries, to establish whether angioplasty can restore coronary flow reserve of atherosclerotic coronary arteries to a normal level. We studied the quantitative cineangiographic changes and the concomitant alterations in coronary flow reserve resulting from angioplasty, as well as the subsequent changes 5 months later. Coronary flow reserve was measured with digital subtraction cineangiography. Angioplasty resulted in an increase in minimal obstruction area (mean ± s.d.) from 1.0 ± 0.5 to 3.6 ± 0.8 mm2 and in coronary reserve (mean ± s.d.) from 1.0 ± 0.3 to 2.5 ± 0.6 immediately following angioplasty. Five months later, a substantial and significant (p < 0.05) late increase in obstruction area (4.3 ± 1.4 mm2) and flow reserve (3.8 ± 1.1) had occurred. In 72% of our patients coronary flow reserve was restored to normal, 5 months after angioplasty.

It is concluded that changes in stenosis geometry are likely to be one of the major determinants of this late normalization of coronary flow reserve.

Keywords

Blood Flow Velocity Coronary Flow Reserve Coronary Blood Flow Normal Coronary Artery Doppler Probe 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Grüntzig AR, Senning A, Siegenthaler WE: Nonoperative dilatation of coronary-artery stenosis: percutaneous transluminal angioplasty. N Engl J Med 301: 61–68, 1979.PubMedCrossRefGoogle Scholar
  2. 2.
    Block PC, Myler RK, Stertzer S, Fallon JT: Morphology after transluminal angioplasty in human beings. N Engl J Med 305: 382–385, 1981.PubMedCrossRefGoogle Scholar
  3. 3.
    Serruys PW, Reiber JHC, Wijns W, Brand M van den, Kooijman CJ, Katen HJ ten, Hugenholtz PG: Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: Diameter versus densitometric area measurements. Am J Cardiol 54: 482–488, 1984.PubMedCrossRefGoogle Scholar
  4. 4.
    Leimgruber PP, Roubin GS, Holtman J, Cotsonis GA, Meier B, Douglas JS, King III SB, Grüntzig AR: Restenosis after successful coronary angioplasty in patients with single-vessel disease. Circulation 73: 710–717, 1986.PubMedCrossRefGoogle Scholar
  5. 5.
    Serruys PW, Wijns W, Reiber JHC, Feyter P de, Brand M van den, Piscione F, Hugenholtz PG: Values and limitations of transstenotic pressure gradients measured during percutaneous coronary angioplasty. Herz 10: 337–342, 1985.PubMedGoogle Scholar
  6. 6.
    Klocke FJ: Measurements of coronary blood flow and degree of stenosis: current clinical implication and continuing uncertainties. J Am Coll Cardial 1: 31–41, 1983.CrossRefGoogle Scholar
  7. 7.
    Hoffman JIE: Maximal coronary flow and the concept of coronary vascular reserve. Circulation 70: 153–159, 1984.PubMedCrossRefGoogle Scholar
  8. 8.
    Wilson RF, White CW: Intracoronary papaverine: an ideal coronary vasodilator for studies of the coronary circulation in conscious humans. Circulation 73: 444–451, 1986.PubMedCrossRefGoogle Scholar
  9. 9.
    Zijlstra F, Serruys PW, Hugenholtz PG: Papaverine: the ideal coronary vasodilator for investigating coronary flow reserve? A study of timing, magnitude, reproducibility, and safety of the coronary hyperemic response after intracoronary papaverine. Cathet Cardiovase Diagn 12: 298–303, 1986.CrossRefGoogle Scholar
  10. 10.
    Cole JS, Hartley CJ: The pulsed Doppler coronary artery catheter. Preliminary report of a new technique for measuring rapid changes in coronary artery flow velocity in man. Circulation 56: 18–25, 1977.PubMedGoogle Scholar
  11. 11.
    Wilson RF, Laughlix DE, Ackell PH, Chilian WM, Holida MD, Hartley CJ, Armstrong ML, Marcus ML, White CW: Transluminal, subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man Circulation 72: 82–92, 1985.Google Scholar
  12. 12.
    Hartley CJ, Cole JS: An ultrasonic pulsed Doppler system for measuring blood flow in small vessels. J Appl Physiol 37: 626–629, 1974.PubMedGoogle Scholar
  13. 13.
    Bates ER, Aueron FM, LeGrand V, LeFree MT, Mancini GBJ, Hodgson JM, Vogel RA: Comparative long-term effects of coronary artery bypass graft surgery and percutaneous transluminal coronary angioplasty on regional coronary flow reserve. Circulation 72: 833–839, 1985.PubMedCrossRefGoogle Scholar
  14. 14.
    Zijlstra F, Ommeren J van, Reiber JHC, Serruys PW: Does the quantitative assessment of coronary artery dimensions predict the physiologic significance of a coronary stenosis? Circulation 75: 1154–1161, 1987.PubMedCrossRefGoogle Scholar
  15. 15.
    Vogel RA: The radiographic assessment of coronary blood flow parameters. Circulation 72: 460–465, 1985.PubMedCrossRefGoogle Scholar
  16. 16.
    Sibley DH, Millar HD, Hartley CJ, Whitlow PL: Subselective measurement of coronary blood flow velocity using a steerable Doppler catheter. J Am Coll Cardiol 8: 1332–1340, 1986.PubMedCrossRefGoogle Scholar
  17. 17.
    Kent KM, Bentivoglio LG, Block PC, Cowley MJ, Dorros G, Gosselin AJ, Grüntzig A, Myler RK, Simpson J, Stertzer SH, Williams DO, Fisher L, Gillespie MJ, Detre K, Kelsey S, Mullin SM, Mock MD: Percutaneous transluminal coronary angioplasty: Report from the Registry of the National Heart, Lung and Blood Institute. Am J Cardiol 49: 2011–2020, 1982.PubMedCrossRefGoogle Scholar
  18. 18.
    Scholl J-M, Chaitman BR, David PR, Dupras G, Brévers G, Val PG, Crépeau J, Lespérance J, Bourassa MG: Exercise electrocardiography and myocardial scintigraphy in the serial evaluation of the results of percutaneous transluminal coronary angioplasty. Circulation 66: 380–390, 1982.PubMedCrossRefGoogle Scholar
  19. 19.
    Kent KM, Bonow RO, Rosing DR, Ewels CJ, Lipson LC, McIntosh CL, Bacharach S, Green M, Epstein SE: Improved myocardial function during exercise after successful percutaneous transluminal coronary angioplasty. N Engl J Med 306: 441–450, 1982.PubMedCrossRefGoogle Scholar
  20. 20.
    Zijlstra F, Reiber JHC, Juillière Y, Serruys PW: Normalization of coronary flow reserve by percutaneous transluminal coronary angioplasty? Am J Cardiol 61: 55–60, 1988.PubMedCrossRefGoogle Scholar
  21. 21.
    O’Neill WW, Walton JA, Bates ER, Colfer HT, Aueron FM, Lefree MT, Pitt B, Vogel RA: Criteria for successful coronary angioplasty as assessed by alterations in coronary vasodilatory reserve. J Am Coll Cardiol 3: 1382–1390, 1984.PubMedCrossRefGoogle Scholar
  22. 22.
    Wilson RF, Aylward PE, Talman CL, White CW: Does percutaneous transluminal coronary angioplasty restore normal coronary vasodilator reserve? Circulation 72 (Supp III): III - 397, 1985 (Abstract).Google Scholar
  23. 23.
    Marcus ML: Effects of cardiac hypertrophy on the coronary circulation. In: The coronary circulation in health and disease, McGraw-Hill Book Co, New York, 1983, pp 285–306.Google Scholar
  24. 24.
    Marcus ML: Effects of anemia and polycythemia on the coronary circulation. In: The coronary circulation in health and disease. McGraw-Hill Book Co., New York, 1983, pp 307–319.Google Scholar
  25. 25.
    Marcus ML, Doty DB, Hiratzka LF, Wright CB, Eastham CL: Decreased coronary reserve: a mechanism for angina pectoris in patients with aortic stenosis and normal coronary arteries. N Engl J Med 307: 1362–1367, 1982.PubMedCrossRefGoogle Scholar
  26. 26.
    Reiber JHC, Serruys PW, Kooijman CJ, Wijns W, Slager CJ, Gerbrands JJ, Schuurbiers JCH, Boer A den, Hugenholtz PG: Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms. Circulation 71: 280–288, 1985.PubMedCrossRefGoogle Scholar
  27. 27.
    Reiber JHC, Kooijman CJ, Slager CJ, Gerbrands JJ, Schuurbiers JCH, Boer A den, Wijns W, Serruys PW, Hugenholtz PG: Coronary artery dimensions from cineangiogramsmethodology and validation of a computer-assisted analysis procedure. IEEE Trans Med Imaging, MI-3: 131–141, 1984.Google Scholar
  28. 28.
    Reiber JHC, Kooijman CJ, Boer A den, Serruys PW: Assessment of dimensions and image quality of coronary contrast catheters from cineangiograms. Cathet Cardiovasc Diagn 11: 521–531, 1985.PubMedCrossRefGoogle Scholar
  29. 29.
    Reiber JHC, Lie SP, Simoons ML, Wijns W, Gerbrands JJ: Computer quantitation location, extent and type of thallium-201 myocardial perfusion abnormalities. In: Proc Int Symposium on Medical Imaging and Image Interpretation ISMIII. IEEE, Cat No 82 CH1804–4: 123–128, 1982.Google Scholar
  30. 30.
    Lie SP, Reiber JHC, Simoons ML, Gerbrands JJ, Kooy PPM, Bakker WH: Computer processing of thallium-201 myocardial scintigrams. In: Proc 2nd Int Conf Visual Phychophysics and Medical Imaging IEEE, Cat No 81CH 1676–6: 19–25, 1981.Google Scholar
  31. 31.
    Hodgson JMcB, LeGrand V, Bates ER, Mancini GBJ, Aueron FM, O’Neill WW, Simon SB, Beauman GJ, LeFree MT, Vogel RA: Validation in dogs of a rapid digital angiographic technique to measure relative coronary blood flow during routine cardiac catheterization. Am J Cardiol 55: 188–193, 1985.CrossRefGoogle Scholar
  32. 32.
    Wilson RF, Aylward PE, Leimbach WH, Talman CL, White CW: Coronary flow reserve late after PTCA — Do the early alterations persist? J Am Coll Cardiol 7: 212A, 1986 (Abstract).Google Scholar
  33. 33.
    Hodgson JMcB, Williams DO: Characterization of coronary flow reserve pre and post successful angioplasty. Circulation 72 (Supp III): III - 456, 1985 (Abstract).Google Scholar
  34. 34.
    Sibley D, Bulle T, Baxley W, Dean L, Chandler J, Whitlow P: Acute changes in blood flow velocity with successful coronary angioplasty. Circulation 74 (Supp. II), II - 193, 1986 (Abstract).Google Scholar
  35. 35.
    Johnson MR, Wilson RF, Skorton DJ, Collins SM, White CW: Coronary lumen area immediately after angioplasty does not correlate with coronary vasodilator reserve; a videodensitometric study. Circulation 74 (Supp II): II - 193, 1986 (Abstract).Google Scholar
  36. 36.
    Bates ER, McGillem MJ, Beats TF, DeBoe SF, Mickelson JK, Mancini GBJ, Vogel RA: Angioplasty induced medial injury, but not endothelial denudation, impairs coronary reactive hyperemia. Circulation 74 (Supp II): II - 498, 1986 (Abstract).Google Scholar
  37. 37.
    Serruys PW, Wijns W, Brand M van den, Meij S, Slager C, Schuurbiers JCH, Hugenholtz PG, Brower RW: Left ventricular performance, regional blood flow, wall motion, and lactate metabolism during transluminal angioplasty. Circulation 70: 25–36, 1984.PubMedCrossRefGoogle Scholar
  38. 38.
    Feldman RL, Conti CR, Pepine CJ: Regional coronary venous flow responses to transient coronary artery occlusion in human beings. J Am Coll Cardiol 2: 1–10, 1983.PubMedCrossRefGoogle Scholar
  39. 39.
    Rothman MT, Baim DS, Simpson JB, Harrison DC: Coronary hemodynamics during percutaneous transluminal coronary angioplasty. Am J Cardiol 49: 1615–1622, 1982.PubMedCrossRefGoogle Scholar
  40. 40.
    Friedman HZ, McGillem MJ, Mancini GBJ, Vogel RA: A new method to measure absolute coronary blood flow using standard angioplasty technique. Circulation 74 (Supp II): II - 497, 1986 (Abstract).Google Scholar
  41. 41.
    Serruys PW, Piscione F, Wijns W, Harmsen E, Brand M van den, Feyter P de, Hugenholtz PG, Jong JW de: Myocardial release of hypoxanthine and lactate during percutaneous transluminal coronary angioplasty: a quickly reversible phenomenon, but for how long?“. In: Transluminal coronary angioplasty: an investigational tool and a non-operative treatment of acute myocardial ischemia, Serruys PW ( Doctoral Thesis, Erasmus University ), 1986 pp 75–92.Google Scholar
  42. 42.
    Marcus ML: The coronary circulation in health and disease. McGraw-Hill Book Co. New York: 1983, pp 65 and 147.Google Scholar
  43. 43.
    Webb SC, Canepa-Anson R, Rickards AF, Poole-Wilson PA: Myocardial potassium loss after acute coronary occlusion in humans. J Am Coll Cardiol 9: 1230–1234, 1987.PubMedCrossRefGoogle Scholar
  44. 44.
    Peterson MB, Machaj V, Block PC, Palacios I, Philbin D, Watkins WD: Thromboxane release during percutaneous transluminal coronary angioplasty. Am Heart J III: 1–6, 1986.Google Scholar
  45. 45.
    Johnson MR, Brayden GP, Ericksen EE, Collins SM, Skorton DJ, Harrison DG, Marcus ML, White CW: Changes in cross-sectional area of the coronary lumen in the six months after angioplasty: a quantitative analysis of the variable response to percutaneous transluminal angioplasty. Circulation 73: 467–475, 1986.PubMedCrossRefGoogle Scholar
  46. 46.
    McPherson DD, Hiratzka LF, Lamberth WC, Brandt B, Hunt M, Kieso RA, Marcus ML, Kerber RE: Delineation of the extent of coronary atherosclerosis by high-frequency epicardial echocardiography. N Engl J Med 316: 304–309, 1987.PubMedCrossRefGoogle Scholar
  47. 47.
    Harrison DG, White CW, Hiratzka LF, Doty DB, Barnes DH, Eastham CL, Marcus ML: The value of lesion cross-sectional area determined by quantitative coronary angiography in assessing the physiologic significance of proximal left anterior descending coronary arterial stenoses. Circulation 69: 1111–1119, 1984.PubMedCrossRefGoogle Scholar

Copyright information

© Kluwer Academic Publishers 1988

Authors and Affiliations

  • Patrick W. Serruys
  • F. Zijlstra
  • Y. Juillière
  • P. J. De Feyter
  • M. Vd Brand
  • H. Suryapranata
  • J. H. C. Reiber

There are no affiliations available

Personalised recommendations