Digital imaging systems for coronary angiography

  • Rüdiger Brennecke
Part of the Developments in Cardiovascular Medicine book series (DICM, volume 87)

Summary

The optimization of digital imaging systems requires the matching of the image quality parameters in the digital and in the analog parts of the system. Therefore, a brief overview on image generation, including the analog components (generator, X-ray tube, image intensifier, video camera) and the digital components (ADC, memory devices, DAC) is given. Next, the differences between the architecture of a standard general-purpose computer and the architectures of image processors are demonstrated. Future developments such as high capacity archival systems and new system architectures are discussed as well. Future systems should be able to handle not only image data, but also physiological data (such as ECG and pressure signals) and general patient information by presenting all of this information in a generalized database environment to the user.

Keywords

Image Intensifier Array Processor Digital Imaging System Digital Angiography Image Quality Parameter 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Leeuw P de: Quality considerations on ciné-imaging and PTCA-fluoroscopy anticipating a digital future. In: Reiber JHC, Serruys PW (eds): State of the art in quantitative coronary arteriography. Martinus Nijhoff, Dordrecht, Boston, 1986, pp 3–16.Google Scholar
  2. 2.
    Shaw C-G, Plewes DB: Quantitative digital subtraction angiography: two scanning techniques for correction of scattered radiation and veiling glare. Radiology 157: 247–253, 1985.PubMedGoogle Scholar
  3. 3.
    Baiter S, Ergun D, Tscholl E, Buchmann F, Verhoeven L: Digital subtraction angiography: fundamental noise characteristics. Radiology 152: 195–198, 1984.Google Scholar
  4. 4.
    Hoffmann FW: Image intensifiers. In: Just H, Heintzen PH (eds): Angiocardiography. Springer-Verlag, Berlin, Heidelberg, New York, 1986, pp 15–20.Google Scholar
  5. 5.
    Seibert JA: Improved fluoroscopic and ciné-radiographic display with pulsed exposures and progressive TV scanning. Radiology 159: 277–278, 1986.PubMedGoogle Scholar
  6. 6.
    James AE, Carroll F, Pickens III DR, Chapman JC, Robinson RR, Pendergrass HP, Zaner R: Medical Image Management. Radiology 160: 847–851, 1986.PubMedGoogle Scholar
  7. 7.
    Brennecke R: Image processors for digital angiography. In: Kereiakes JG, Thomas SR, Orton CG (eds): Digital radiology. Plenum, New York, 1986, pp 13–33.Google Scholar
  8. 8.
    Heintzen PH, Brennecke R: Digital imaging in cardiovascular radiology. Thieme, Stuttgart, New York, 1983.Google Scholar
  9. 9.
    Kruger RA, Mistretta CA, Houk TL, Riederer SJ, Shaw CG, Goodsitt MM, Crummy AB, Zwiebel W, Lancaster JC, Rowe GG, Flemming D: Computerized fluoroscopy in real time for noninvasive visualization of the cardiovascular system. Radiology 130: 49–57, 1979.PubMedGoogle Scholar
  10. 10.
    Kruger RA: A method for time domain filtering using computerized fluoroscopy. Med Phys 8: 466–470, 1981.PubMedCrossRefGoogle Scholar
  11. 11.
    Bürsch JH, Hahne HJ, Brennecke R, Grönemeier D, Heintzen PH: Assessment of arterial blood flow measurements by digital angiography. Radiology 141: 39–47, 1981.PubMedGoogle Scholar
  12. 12.
    Vogel RA: Digital assessment of coronary flow reserve. In: Buda AJ, Delp EJ (eds): Digital Cardiac Imaging. Martinus Nijhoff, Boston, 1985, pp 106–115.CrossRefGoogle Scholar
  13. 13.
    Brennecke R, Hahne HJ, Bürsch JH, Heintzen PH: Digital videodensitometry: some approaches to radiographic image restoration and analysis. In: Heuck FHW (ed): Radiological functional analysis, Springer, New York, 1983, pp 79–88.Google Scholar
  14. 14.
    Shaw C-G, Ergun DL, Myerowitz PD, Van Lysel MS, Mistretta CA, Zarnstorff WC, Crummy AB: A technique for scatter and glare correction for videodensitometric studies in digital subtraction videoangiography. Radiology 142: 209–213, 1982.PubMedGoogle Scholar
  15. 15.
    Heintzen PH, Bürsch JH: Roentgen-video-techniques. Thieme, Stuttgart, New York, 1978.Google Scholar
  16. 16.
    Sigwart U, Heintzen PH: Ventricular wall motion. Thieme, Stuttgart, New York, 1984.Google Scholar
  17. 17.
    Reiber JHC, Serruys PW: State of the art in quantitative coronary arteriography. Martinus Nijhoff Publishers, Dordrecht, Boston, Lancaster, 1986.Google Scholar
  18. 18.
    Brennecke R, Jung D, Clas W, Erbel R, Meyer J: TALISMAN: An interpreter language for image sequence management in digital angiography and echocardiography. Comput Cardiol: 363–366, 1985.Google Scholar

Copyright information

© Kluwer Academic Publishers 1988

Authors and Affiliations

  • Rüdiger Brennecke

There are no affiliations available

Personalised recommendations