Multiple Use of Hemodialyzers

  • Norman Deane
  • Robert J. Wineman

Abstract

Repeated hemodialysis treatment for chronic renal failure was initiated by Belding Scribner and colleagues (1) in 1960. The earliest dialysis procedures included several features which were soon employed for multiple use of dialyzers. For example, Scribner rinsed the blood and dialysate compartments with water, and sterilized both compartments with formaldehyde, since components of the flat plate dialyzers were not sterile when assembled. The dialyzer remained filled with formalin until the time for dialysis, when it was flushed with saline to remove the formaldehyde. These steps resemble those now employed for multiple use of dialyzers.

Keywords

Sodium Hypochlorite Artif Organ Peracetic Acid Dialysis Fluid Blood Compartment 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Scribner BH, Buri R, Caner JEZ, Hegstrom R, Burnell JM: The treatment of chronic uremia by means of intermittent dialysis: a preliminary report. Trans Am Soc Artif Intern Organs 6:114, 1960PubMedGoogle Scholar
  2. 2.
    Pendras JP, Cole JJ, Tu WH, Scribner BH: Improved technique of continuous flow hemodialysis. Trans Am Soc Artif Intern Organs 7: 27, 1961PubMedGoogle Scholar
  3. 3.
    Brown HW, Maher JF, Lapierre L, Bledsoe FH, Schreiner GE: Clinical problems related to the prolonged artificial maintenance of life by hemodialysis in chronic renal failure. Trans Am Soc Artif Intern Organs 8: 281, 1962PubMedGoogle Scholar
  4. 4.
    Merrill JP, Schupak E, Cameron E, Hampers CL: Hemodialysis in the home. JAMA 190: 468, 1964PubMedGoogle Scholar
  5. 5.
    Shaldon SH, Silva H, Rosen SM: Technique of refrigerated coil preservation haemodialysis with femoral venous catheterization. Br Med J 2: 411, 1964PubMedCrossRefGoogle Scholar
  6. 6.
    Pollard TL, Barnett BMS, Eschbach JW, Scribner BH: A technique for storage and multiple re-use of the Kiil dialyzer and blood tubing. Trans Am Soc Artif Intern Organs 13: 24, 1967Google Scholar
  7. 7.
    Deane N, Bemis JA., Multiple Use of Hemodialyzers, New York, Manhattan Kidney Center, National Nephrology Foundation,1982, Appendices 1, 2Google Scholar
  8. 8.
    Deane N: A survey of dialyzer reuse practice in the United States 1984. in: Hemodialyzer Reuse; Issues and Solutions, Arlington, VA, Association for Advancement of Medical Instrumentation, 1985, p 1Google Scholar
  9. 9.
    Bland L, Alter M, Favero M, Carson L, Cusick L: Hemodialyzer reuse: Practces in the United States and implications for infection control. Trans Am Soc Artif Intern Organs 31: 556, 1985Google Scholar
  10. 10.
    Challah S, Wing AJ, Brunner FP, Brynger HOA, Oules R, Seiwood NH: Use and reuse of dialyzers in Europe. in: Guide to Reprocessing of Hemodialyzers edited by Deane N,Wineman RJ, Bemis JA, Boston,Martinus Nijhoff,1986,p99CrossRefGoogle Scholar
  11. 11.
    Sadler JH: Reuse workshop report, in: National Workshop on Reuse of Consumables in Hemodialysis, Washington, DC, Kidney Disease Coalition, 1982, Appendix AGoogle Scholar
  12. 12.
    Deane N, Bemis JA: Multiple Use of Hemodialyzers, New York, Manhattan Kidney Center, National Nephrology Foundation, 1982,p 64Google Scholar
  13. 13.
    AAMI Recommended Practices for Reuse of Hemodialyzers. Arlington, VA., Association for Advancement of Medical Instrumentation, 1986.Google Scholar
  14. 14.
    National Kidney Foundation, revised standards for reuse of hemodialyzers. Contemp Dial 5(2): 29, 37, 1984Google Scholar
  15. 15.
    Ogden DA: New-dialyzer syndrome. N Engl J Med 302: 1262, 1980PubMedGoogle Scholar
  16. 16.
    Jacobs C, Brunner FP, Chantier C, Donckerwolcke RA, Gurland HJ, Hathway RA, Selwood NH, Wing AJ: Combined reports on regular dialysis and transplantation in Europe. VII. Proc Eur Dial Transplant Assoc 14: 3, 1977PubMedGoogle Scholar
  17. 17.
    Wing AJ, Brunner FP, Brynger H, Chantier C, Donckerwolcke RA, Gurland HJ, Jacobs C, Selwood NH: Mortality and morbidity of re-using dialysers. Br Med J 2: 853, 1978PubMedCrossRefGoogle Scholar
  18. 18.
    Held PJ, Pauly MV, Diamond L: Survival analysis of patients undergoing dialysis. JAMA 257: 645, 1987PubMedCrossRefGoogle Scholar
  19. 19.
    National Institute of Arthritis, Diabetes and Digestive and Kidney Diseases: Briefing paper on NIH response to technology assessment report on dialyzer reuse. In staff report, Hazards in Reuse of Disposable Dialysis Devices serial No. 99-K US Govt. Printing Office, 383Google Scholar
  20. 20.
    Ogden DA: Clinical response to new and reprocessed dialyzers. in: Guide to Reprocessing of Hemodialyzers, edited by Deane N, Wineman RJ, Bemis JA, Boston, Martinus Nijhoff, 1986,p 87CrossRefGoogle Scholar
  21. 21.
    Ing TS, Daugirdas JT, Popli S, Ghandi VC: First-use syndrome with cupro-ammonium cellulose dialyzers. Int J Artif Organs 6: 235, 1983PubMedGoogle Scholar
  22. 22.
    Ing TS, Ivanovich PT, Daugirdas JT: First-use syndrome and hypersensitivity during hemodialysis: some pieces of the puzzle are falling into place. Artif Organs 11: 79, 1987PubMedCrossRefGoogle Scholar
  23. 23.
    Daugirdas JT, Ing TS: Classification of first-use reactions. IntJ Artif Organs 9: 194, 1986Google Scholar
  24. 24.
    Villarroel F, Ciarkowski AA: A survey of hypersensitivity reactions in hemodialysis. Artif Organs 9: 231, 1985PubMedCrossRefGoogle Scholar
  25. 25.
    Nicholls AJ: Hypersensitivity to hemodialysis: The United Kingdom experience. Artif Organs 11: 87, 1987PubMedCrossRefGoogle Scholar
  26. 26.
    Bok DV, Pascual L, Herberger C, Sawyer R, Levin NW: Effect of multiple use of dialyzers on intradialytic symptoms. Proc Clin Dial Transplant Forum 10: 92, 1980PubMedGoogle Scholar
  27. 27.
    Kant KS, Pollack VE, Cathey M, Goetz D, Berlin R: Multiple use of dialyzers: safety and efficacy. Kidney Int 19: 728, 1981PubMedCrossRefGoogle Scholar
  28. 28.
    Bennett IL, Cluff LE: Bacterial pyrogens. Pharmacol Rev 9: 427, 1957PubMedGoogle Scholar
  29. 29.
    Petersen NJ, Carson LA, Favero MA: Bacterial endotoxin in new and reused hemodialyzers: a potential cause of endo toxemia. Trans Am Soc Artif Intern Organs 27: 155, 1981PubMedGoogle Scholar
  30. 30.
    Deane N, Bemis JA: Multiple Use of Hemodialyzers. New York, Manhattan Kidney Center, National Nephrology Foundation, 1982,p 99Google Scholar
  31. 31.
    Ogden DA: Clinical response to new and reprocessed dialyzers. in: Guide to Reprocessing of Hemodialyzers, edited by Deane N, Wineman RJ, Bemis JA, Boston, Martinus Nijhoff, 1986,p 91Google Scholar
  32. 32.
    Favero MS, Deane N, Leger RT, Sosin AE: Effect of multiple use of hemodialyzers on hepatitis B incidence in patients and staff. JAMA 245:166, 1981PubMedCrossRefGoogle Scholar
  33. 33.
    Fassbinder W, Koch KM: Immune response to reuse: anti-N- like antibodies, in: Guide to Reprocessing of Hemodialyzers, edited by Deane N, Wineman RJ, Bemis JA, Boston, Martinus Nijhoff, 1986, p 135CrossRefGoogle Scholar
  34. 34.
    Lewis KJ, Dewar PJ, Ward MK, Kerr DNS: Formation of anti-N-like antibodies in dialysis patients: effect of different methods of dialyser rinsing to remove formaldehyde. Clin Nephrol 15: 39, 1981PubMedGoogle Scholar
  35. 35.
    Bolan GA, Reingold AL, Carson LA, Silcox VA, Woodley CL, Hayes PS, Hightower AW, McFarland L, Brown JW III, Petersen NJ, Favero MS, Good RC, Broome CV: Infections with Mycobacterium chelonei in patients receiving dialysis and using processed hemodialyzers. J Infect Dis 152: 1013, 1985PubMedCrossRefGoogle Scholar
  36. 36.
    Favero MS: Distinguishing between high-level disinfection, reprocessing and sterilization. AAMI Technology Assessment Report No. 6–83. Arlington, VA, Association for the Advancement of Medical Instrumentation, 1983Google Scholar
  37. 37.
    Kaplow LS, Goffinet JA: Profound neutropenia during the early phase of hemodialysis. JAMA 203, 1135,1968PubMedCrossRefGoogle Scholar
  38. 38.
    Lowrie EG, Hakim RM: The effect on patient health of using reprocessed artificial kidneys. Proc Clin Dial Transplant Forum 10: 86, 1980PubMedGoogle Scholar
  39. 39.
    Savdi E, Bruce L, Vincent PC: Modified neutropenic response to reused dialyzers in patients with chronic renal failure. Clin Nephrol 8: 422, 1977Google Scholar
  40. 40.
    Hakim RM, Lowrie EG: Effect of dialyzer reuse on leukopenia, hypoxemia and total hemolytic complement system. Trans Am Soc Artif Intern Organs 26: 159, 1980PubMedGoogle Scholar
  41. 41.
    Charoenpanick R, Pollack VE, Kant KS, Robson MD, Cathey M: Effect of first and subsequent use of hemodialyzers on patient well being: The rise and fall of a syndrome associated with new dialyzer use. Artif Organs 11: 123, 1987CrossRefGoogle Scholar
  42. 42.
    Dumler F, Zasuwa G, Levin NW: Effect of dialyzer reprocessing methods on complement activation and hemodialyzer-related symptoms. Artif Organs 11: 128, 1987PubMedCrossRefGoogle Scholar
  43. 43.
    Gagnon R, Adkar V, Kaye M: Dialyzer reuse following manual reprocessing with a new sterilant, REN-NEW-D. Artif Organs 11: 132, 1987PubMedCrossRefGoogle Scholar
  44. 44.
    Vanholder R, Ringoir S: Influence of reuse and of reuse sterilants on first-use syndrome. Artif Organs 11: 137, 1987PubMedCrossRefGoogle Scholar
  45. 45.
    Howell ED, Perkins HA: Anti-N-like antibodies in the sera of patients undergoing chronic hemodialysis. Vox Sang 23: 291, 1972PubMedCrossRefGoogle Scholar
  46. 46.
    Beizer FO, Kountz SL, Perkins HA: Red cell cold autoagglutinins as a cause of failure of renal alio transplantation. Transplantation 11: 422, 1971Google Scholar
  47. 47.
    Lewis KJ, Ward MK, Kerr DNS: Residual formaldehyde in dialyzers: quantity, location and the effect of different methods of rinsing. Artif Organs 5: 269, 1981PubMedCrossRefGoogle Scholar
  48. 48.
    Henderson LW, Chenoweth DE: Immune response to reuse: anaphylactoxins and IgE. in: Guide to Reprocessing of Hemodialyzers, edited by Deane N, Wineman RJ, Bemis JA, Boston, Martinus Nijhoff, 1986, p 151CrossRefGoogle Scholar
  49. 49.
    Yudis M, Sirota RA, Stein HD: Dialyzer hypersensitivity reactions associated with reuse. Abstracts Am Soc Artif Inter Organs 14: 59, 1985Google Scholar
  50. 50.
    Dorson W., Pizziconi V., Hyde G.,Technical considerations in multiple use of Dialyzers. In: Proceedings of the National Workshop on the Reuse of Consumables in Hemodialysis, Edited By Sadler J., Washington Dc, Kidney Disease Coalition, 1983, P11.Google Scholar
  51. 51.
    Deane N, Bemis JA: Multiple Use of Hemodialyzers, New York, National Nephrology Foundation, 1982, p 31Google Scholar
  52. 52.
    Wineman RJ: Automated reprocessing, in: Guide to Reprocessing of Hemodialyzers, edited by Deane N, Wineman RJ, Bemis JA, Boston, Martinus Nijhoff, 1986, p 163CrossRefGoogle Scholar
  53. 53.
    Man NK, Lebkiri B, Polo P, De Sainte-Lorette E, Lemaire A, Funck-Brentano JL: Prevention of anti-N-like antibodies development with nonformaldehyde reuse procedure. Proc Clin Dial Transplant Forum 10:18, 1980PubMedGoogle Scholar
  54. 54.
    Gagnon RF, Kaye M: Hemodialysis neutropenia and dialyzer reuse: role of the cleansing agent. Uremia Invest 8:17, 1984PubMedGoogle Scholar
  55. 55.
    Leuhman D, Hirsch D, Carlson G, Constantini E, Keshaviah P: Dialyzer reuse in a large dialysis program. Trans Am Soc Artif Intern Organs 28: 76, 1982Google Scholar
  56. 56.
    Gotch FA: Solute and water transport and sterilant removal in reused dialyzers. in: Guide to Reprocessing of Hemodialyzers, edited by Deane D, Wineman RJ, Bemis JA, Boston, Martinus Nijhoff, 1986, p 39CrossRefGoogle Scholar
  57. 57.
    Gotch FA: Quality control tests for validation of dialyzer performance. in: Hemodialyzer Reuse: Issues and Solutions, AAMI Technology Assessment Report 10–85, Arlington, VA, Association for Advancement of Medical Instrumentation, 1985, p 37Google Scholar
  58. 58.
    Sargent J, Gotch F: Principles and biophysics of dialysis, in: Replacement of Renal Function by Dialysis, 2nd edition, edited by Drukker W, Parsons FM, Maher JF, The Hague, Martinus Nijhoff, 1983, p 53Google Scholar
  59. 59.
    Deane N., Bemis JA., Multiple Use of Hemodialyzers. New York, Manhattan Kidney Center, National Nephrology Foundation, 1982, Appendix 6, p 191Google Scholar
  60. 60.
    Favero MS, Bland LA: Microbiologic principles applied to reprocessing hemodialyzers. in: Guide to Reprocessing of Hemodialyzers. edited by Deane N, Wineman RJ, Bemis JA, Boston, Martinus Nijhoff, 1986, p 63CrossRefGoogle Scholar
  61. 61.
    Favero MS, Petersen NJ: Microbiological guidelines for hemodialysis systems. Dial Transplant 6: 34, 1977Google Scholar
  62. 62.
    Association for the Advancement of Medical Instrumentation: American National Standards for Hemodialysis Systems, Arlington, VA, Association for the Advancement of Medical Instrumentation, 1981Google Scholar
  63. 63.
    Petersen NJ: Microbiologic hazards associated with reuse of hemodialyzers. in: Proceedings of National Workshop on Reuse of Consumables in Hemodialysis, Baltimore, Kidney Disease Coalition, 1982, p 121Google Scholar
  64. 64.
    Deane N, Maude DL, Bemis JA: Reprocessing techniques, in: Guide to Reprocessing of Hemodialyzers, edited by Deane N, Wineman RJ, Bemis JA, Boston, Martinus Nijhoff, 1986, p 28CrossRefGoogle Scholar
  65. 65.
    Hakim RM, Friedrich RA, Lowrie EG: Formaldehyde kinetics and bacteriology in dialyzers. Kidney Int 28: 936, 1985PubMedCrossRefGoogle Scholar
  66. 66.
    Deane N., Bemis JA., Multiple Use of Hemodialyzers, New York, National Nephrology Foundation, 1982, Appendix 5, p 188.Google Scholar
  67. 67.
    Gotch FA, Keen ML: Formaldehyde kinetics in reused dialyzers. Trans Am Soc Artif Intern Organs 29: 396, 1983PubMedGoogle Scholar
  68. 68.
    Kaye M, Barber E, Gagnon R: Residual formaldehyde in new and reused dialyzers. Trans Am Soc Artif Intern Organs 31:644, 1985PubMedGoogle Scholar
  69. 69.
    Ansorge W, Pelger M, Dietrich W, Baurmeister U: Ethylene oxide in dialyzer rinsing fluid: Effect of rinsing technique, dialyzer storage time, and potting compound. Artif Organs 11: 118, 1987PubMedCrossRefGoogle Scholar
  70. 70.
    Ing TS, Daugirdas J: Extractable ethylene oxide from cuproammonium cellulose plate dialyzers: Importance of potting compound. Trans Am Soc Artif Intern Organs 32: 108, 1986Google Scholar
  71. 71.
    Berkseth R, Leuhmann D, McMichael C, Keshaviah P, Kjellstrand C: Peracetic acid for reuse of hemodialyzers: Clinical studies. Trans Am Soc Artif Intern Organs 30: 270, 1984PubMedGoogle Scholar
  72. 72.
    Bauer H, Brunner H, Franz HE: Experience with the disinfectant peroxyacetic acid for hemodialyzer reuse. Trans Am Soc Artif Intern Organs 29: 662, 1983PubMedGoogle Scholar
  73. 73.
    Deane N, Wineman RJ: Comparative evaluation of automated devices for reprocessing hemodialyzers: Intradialytic patient response. Trans Am Soc Artif Intern Organs 30: 498, 1984PubMedGoogle Scholar
  74. 74.
    Wineman RJ: New Technologies in automated reprocessing of hemodialyzers. in: Hemodialyzer Reuse: Issues and Solutions, Arlington, VA, Association for Advancement of Medical Instrumentation, 1985,p 50Google Scholar
  75. 75.
    Levin NW, Messana A, Messana MA: Record-keeping procedures for dialyzer reuse, in: Guide to Reprocessing of Hemodialyzers, edited by Deane N, Wineman RJ, Bemis JA, Boston, Martinus Nijhoff, 1986, p 75CrossRefGoogle Scholar
  76. 76.
    Federal Register Vol 52, No. 116, Wednesday June 17, 1987: Proposed Rules, p 23055Google Scholar
  77. 77.
    Deane N, Bemis JA.,: Multiple Use of Hemodialyzers, New York, National Nephrology Foundation, 1982, Appendix 11, p 219Google Scholar
  78. 78.
    Ogden DA: Quality control and quality assurance are different. Nephrology News and Issues, 24, July, 1987Google Scholar
  79. 79.
    Keshaviah P: Benefits of large solute removal vs pyrogen risk. Nephrology News and Issues, 32, July, 1987Google Scholar

Copyright information

© Kluwer Academic Publishers 1989

Authors and Affiliations

  • Norman Deane
  • Robert J. Wineman

There are no affiliations available

Personalised recommendations