Abstract
Several factors are important in the design of intracoronary ultrasonic imaging catheters. The mechanical considerations are first discussed and equations are developed for calculating the forces affecting catheter passage in a blood vessel. These equations are applied to the problem of Judkins (transfemoral) coronary artery catheterization, using previously described anatomical information and catheter moduli values. The introduction force is calculated for each position along the vessel for both a high and low value of estimated catheter-wall friction (coefficient values of 0.04 and 0.2, respectively). Next, the problem of catheter or transducer rotation is analytically described. The advantages of spiral drive cables with high torsional rigidity and low bending stiffness are numerically shown. Finally, several methods and considerations are given for electrical connection to the transducer. These results and equations should facilitate the design of intracoronary ultrasound imaging devices in the future.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Grossman W. Cardiac Catheterization and Angiography, Lea and Febiger, Philadelphia 1980.
Cournand A. Cardiac catheterization: Development of the technique, its contributions to experimental medicine, and its initial applications in man. Acta Medica Scandinavica 1975; Supp. 579: 1–32.
Zimmerman HA. Intravascular Catheterization. Charles C. Thomas, Springfield, 111, 1966.
Stenquist Q, Curelaru I, Lindner E, Gustavson B. Stiffness of central venous catheters. Acta Anaesthesiol Scand 1983; 27:153–157.
Martin RW, Johnson CC. Engineering considerations of catheters for intravascular ultrasonic measurements. SPIE Proceedings, Microsensors and Catheter Based Sensing 1989 (in press).
Jang DG. Angioplasty, McGraw Hill Book Co., New York 1986.
Bowden FP, Tabor D. Friction and Lubrication, Methuen & Co. Ltd., London 1956.
Booser RE [ed]. CRC Handbook of Lubrication: Theory and Practice of Tribology, CRC Press, Inc., Boca Raton, Florida, pp. 47, 468, 632, & 643 1984.
Gupta BS, Wolf KW, Postlethwait RW. Effect of suture material and construction on frictional properties of sutures. Surgery, Gynecology & Obstertrics. 1985; 161: 12–16.
Nickel JC, Olson ME, Costerton JW. In vivo coefficient of kinetic friction: study of urinary catheter biocompatibility. Urology 1987; 29: 501–503.
Bowden FP, Tabor D. The Friction and Lubrication of Solids: Appendix X, Some typical values of friction - Metal Surfaces - Unlubricated, ed. by Fowler RH, Kapitza P, Mott NF, Bullard EC, Oxford University Press, pp. 322, 1954.
Souders M. The Engineer’s Companion: A Concise Handbook of Engineering Fundamentals, John Wiley and Sons, Inc. New York pp. 102–31: 1966.
Higdon A, Ohlsen EH, Stiles WB. Mechanics of Materials, John Wiley & Sons, Inc. New York, NY, p. 486, 1960.
Bom N, Lancee CT, Egmond FC. An ultrasonic intracardiac scanner. Ultrasonics 1972; 10: 72–6.
Martin RW, Silverstein FE, Kimmey MB, Jiranek G, Proctor A. B mode imaging and Doppler ultrasonic catheters for use with fiber optic endoscopes. SPIE Proceedings, Microsensors and Catheter Based Imaging Technology 1988; 904: 121–6.
Martin RW, Silverstein FE, Kimmey MB, A 20 MHz ultrasound system for imaging the intestinal wall. Ultrasound Med Biol 1989 (in press).
Silverstein FE, Martin RW, Kimmey MB, Jiranek GC, Franklin DW, Proctor A. Experimental evaluation of an endoscopic ultrasound probe: in vitro and in vivo canine studies. Gastroenterology 1989; 96: 1058–62.
Rotary Motion Flexible Shafts, Technical Bulletin, S.S.White Industrial Products, Penwalt, 151 Old New Brunswick Road, PO Box 68, Piscataway, NJ.
Personal Communication. Mitchell R, Baird Industries, Ho-Ho-Kus, New Jersey 1989.
Bo WJ, Meschan I, Krueger WA. Basic Atlas of Cross Sectional Anatomy, W.B. Saunders Company, Philadelphia, PA, pp. 76–186, 1980.
Dodge JT, Brown BG, Bolson EL, Dodge HT. Intrathoracic spatial location of specified coronary segments on the normal human heart. Applications in quantitative arteriography, assessment of regional risk and contraction, and anatomic display. Circulation 1988; 78: 1167–80.
Martin RW, Watkins DW. An ultrasonic catheter for intravascular measurement of blood flow: Technical details, IEEE Sonics and Ultrasonics, 1980; SV-27: 227–86.
Martin RW, Gilbert DA, Silverstein FE, Deltenre M, Tytgat G, Gange RK, Myers J. An endoscopic Doppler probe for assessing intestinal vasculature. Ultrasound Med. Biol. 1985; 11: 61–9.
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 1989 Kluwer Academic Publishers
About this chapter
Cite this chapter
Martin, R.W., Johnson, C.C. (1989). Design characteristics for intravascular ultrasonic catheters. In: Bom, N., Roelandt, J. (eds) Intravascular ultrasound. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-1007-2_15
Download citation
DOI: https://doi.org/10.1007/978-94-009-1007-2_15
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-010-6943-4
Online ISBN: 978-94-009-1007-2
eBook Packages: Springer Book Archive