Abstract
Methods currently used for the determination of NO2 in the atmosphere require power supplies and some protection from the environment and, in the case of the generally accepted chemiluminescence analyser, a large initial capital outlay for the purchase of the instrument, data logger and retrieval systems as well as regular skilled maintenance in use. These disadvantages have hindered the accumulation of a data base of NO2 concentrations similar to that available for SO2 in some countries.
Recently a passive diffusion tube sampler has been validated for ambient NO2 sampling. This simple and inexpensive device collects by molecular diffusion of the gas along a tube of accurately known dimensions to an efficient absorbent of triethanolamine coated onto stainless steel mesh discs. Nitrogen dioxide is determined by the well established Griess-Saltzman spectrophotometric method.
The sampler described is an integrating device and its reliance on diffusion for NO2 collection renders it unsuitable for short term measurements. Its collection rate of “72 cm3 hr-1” gives, however a limit of detection of about 200 ppb hours allowing concentrations down to 1–2 ppb to be measured with sampling periods of one week.
In this paper the preparation, analysis and performance of the sampler are discussed and data are presented for its validation in the field against the chemiluminiscence method. Finally examples are included of its use in environmental investigations, some of which could hardly have been contemplated with hitherto available methods.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
PALMES, E.D., GUNNISON, A.I., DIMATTIO, J. and TOMCZYK, C. Personal sampler for nitrogen dioxide. Am. Ind. Hyg. Assoc. J. 37, 570 – 577 (1976).
ATKINS, D.H.F., SANDALLS, J., LAW, D.V., HOUGH, A.M. and STEVENSON, K. The measurement of nitrogen dioxide in the outdoor environment using simple diffusion tube samplers. United Kingdom Atomic Energy authority Report AERE R 12133 (1986).
ATKINS, D.H.F., LAW D.V. and NEATE, M. A survey of nitrogen dioxide in the City of Glasgow and surrounding districts. United Kingdom Atomic Energy Authority Report AERE R 12447 (1989).
ATKINS, D.H.F., and LAW D.V. Nitrogen dioxide survey in the Victoria area of London using passive diffusion tube samplers. United Kingdom Atomic Energy Authority Report AERE 12107 (1989).
ATKINS, D.H.F., LAW, D.V., and SANDALLS, R. The distribution of nitrogen dioxide in the United Kingdom. A first report. United Kingdom Atomic Energy Authority Report AERE R 13304 (1989).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1990 ECSC, EEC, EAEC, Brussels and Luxembourg
About this chapter
Cite this chapter
Atkins, D.H.F. (1990). A Passive Diffusion Tube Sampler for the Measurement of Atmospheric NO2. A New Approach . In: Restelli, G., Angeletti, G. (eds) Physico-Chemical Behaviour of Atmospheric Pollutants. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-0567-2_3
Download citation
DOI: https://doi.org/10.1007/978-94-009-0567-2_3
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-010-6743-0
Online ISBN: 978-94-009-0567-2
eBook Packages: Springer Book Archive