Abstract
We built a Placido’s disc videokeratographic system intended for eye examination of small animals. To derive the corneal topology and other corneal biometric parameters we rely on precise extraction of Placido ring patterns. However, since the images from CCD are noisy, image enhancement is necessary as a pre-processing procedure in order to prevent further noise magnification during the corneal surface topography reconstruction. In this study, two popular image enhancement methods, namely Gabor Filtering (GF) and Multiscale Vessel Enhancement Filtering (MVEF), are quantitatively evaluated in the context of image enhancement before corneal reconstruction. The two methods were tested on 21 images of steel balls with different diameters. Both methods have been demonstrated to be useful for Placido ring extraction; however, the GF method showed better performance on images of steel balls with smaller diameter. Compared to the GF method, the MVEF method performed better on images of steel balls with larger diameter. The result of the present work implies that the two methods should be used cooperatively.
Keywords
- Videokeratography
- Gabor filtering
- Multiscale vessel enhancement filtering
This is a preview of subscription content, access via your institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Kee CS, Deng Li (2008) Astigmatism associated with experimentally induced myopia or hyperopia in chickens. Invest Ophthalmol Vis Sci 49(3): 858–867
Kee CS, Huang LF, Qiao-Grider Y (2003) Astigmatism in infant monkeys reared with cylindrical lenses. Vision Res 43(26):2721–2739
Schmid K, Wildsoet CF (1997) Natural and imposed astigmatism and their relation to emmetropization in the chick. Exp Eye Res 64(5):837–847
Alonso-Caneiro D, Iskander DR, Collins MJ (2008) Computationally efficient interference detection in videokeratoscopy images. In: 2008 IEEE 10th Workshop on Multimedia Signal Processing, pp 486–490 Oct 2008
Zhong X, Ge J, Smith EL 3rd (2004) Compensation for experimentally induced hyperopic anisometropia in adolescent monkeys. Invest Ophthalmol Vis Sci 45(10):3373–3379
Paulino LV, Paulino E, Barros RA, Salles AG, Rehder JR (2005) Corneal topographic alteration after radiofrequency application to an animal model. Arq Bras Oftalmolog 68(4):451–456
Norton TT, Amedo AO, Siegwart JT Jr (2006) Darkness causes myopia in visually experienced tree shrews. Invest Ophthalmol Vis Sci 47(11):4700–4707
Hanuch OE, Agrawal VB, Bassage S, delCerro M, Aquavella JV (1998) Myopic picosecond laser keratomileusis with the neodymium-yttrium lithium fluoride laser in the cat cornea. Ophthalmology 105(1):142–149
Busin M, Yau CW, Yamaguchi T, McDonald MB, Kaufman HE (1986) The effect of collagen cross-linkage inhibitors on rabbit corneas after radial keratotomy. Invest Ophthalmol Vis Sci 27(6):1001–1005
Carrington SD, Woodward EG (1984) Woodward, The topography of the anterior surface of the cat’s cornea. Curr Eye Res 3(6):823–826
Oshita T, Hayashi S, Inoue T, Hayashi A, Maeda N, Kusaka S, Ohji M, Fujikado T, Tano Y (2001) Topographic analysis of astigmatism induced by scleral shortening in pig eyes. Graefe’s Arch Clin Exp Ophthalmol 239(5):382–386
Alonso-Caneiro D, Iskander DR, Collins MJ (2008) Estimating Corneal Surface Topography in Videokeratoscopy in the Presence of Strong Signal Interference. IEEE Trans Biomed Eng 55(10):2381–2387
Gabor D (1946) Theory of communication. Part 1: The analysis of information. J Ins Electr Eng 93(26):429–441
Daugman JG (1988) Complete discrete 2-D Gabor transforms by neural networks for image analysis and compression. IEEE Trans Acoust Speech Signal Process 36(7):1169–1179
Dunn D, Higgins WE (1995) Optimal Gabor filters for texture segmentation. IEEE Trans Image Process 4(7):947–964
Dunn D, Higgins WE, Wakeley J (1994) Texture segmentation using 2-D Gabor elementary functions. IEEE Trans Pattern Anal Mach Intell 16(2):130–149
Zhou Y, Zheng Y-P (2009) Enhancement of muscle fibers in ultrasound images using gabor filters. In: Ultrasonics Symposium (IUS), 2009 IEEE International, pp 2296–2299
Zhou Yongjin, Zheng Yong-ping (2011) Longitudinal enhancement of the hyperechoic regions in ultrasonography of muscles using a gabor filter bank approach: a preparation for semi-automatic muscle fiber orientation estimation. Ultrasound Med Biol 37(4):665–673
Frangi AF, Wiro JN, Koen LV, Max AV (1998) Multiscale vessel enhancement filtering. Lect Notes Comput Sci, vol 1496, pp 130–137
Wink O, Niessen WJ, Viergever MA (2004) Multiscale vessel tracking. IEEE Trans Med Imagin 23(1):130–133
Weldon TP, Higgins WE, Dunn DF (1996) Gabor filter design for multiple texture segmentation. Opt Eng 10(35):2852–2863
Jain AK, Farrokhnia F (1991) Unsupervised texture segmentation using Gabor filters. Pattern Recogn 24(12):1167–1186
Teuner A, Pichler O, Hosticka BJ (1995) Unsupervised texture segmentation of images using tuned matched gabor filters. IEEE Trans Image Process 4(6):863–870
Yang J, Liu L, Jiang T, Fan Y (2003) A modified Gabor filter design method for fingerprint image enhancement. Pattern Recogn Lett 24(12):1805–1817
Mehrotra R, Namuduri KR, Ranganathan N (1992) Gabor filter-based edge detection. Pattern Recogn 25(12):1479–1494
Ng H-F (2006) Automatic thresholding for defect detection. Pattern Recogn Lett 27(14):1644–1649
Otsu N (1979) A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern 9(1):62–66
Acknowledgments
This work is supported in part by grants from National Natural Science Foundation of China (NSFC: 81171402, 61103165), the next generation communication technology Major project of National S&T(2013ZX03005013), Guangdong Innovative Research Team Program (GIRTF-LCHT, No. 2011S013), Low-cost Healthcare Programs of Chinese Academy of Sciences and International Science and Technology Cooperation Program of Guangdong Province (2012B050200004) and Shenzhen Key Laboratory for Low-cost Healthcare (CXB201005260056A).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer Science+Business Media Dordrecht
About this paper
Cite this paper
Chen, B. et al. (2014). Image Enhancement Methods for a Customized Videokeratography System Designed for Animals with Small Eyes. In: Li, S., Jin, Q., Jiang, X., Park, J. (eds) Frontier and Future Development of Information Technology in Medicine and Education. Lecture Notes in Electrical Engineering, vol 269. Springer, Dordrecht. https://doi.org/10.1007/978-94-007-7618-0_98
Download citation
DOI: https://doi.org/10.1007/978-94-007-7618-0_98
Published:
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-007-7617-3
Online ISBN: 978-94-007-7618-0
eBook Packages: EngineeringEngineering (R0)