Abstract
This study compared the characteristics of temperature of the electronic moxibustion and Gu-Gwan moxibustion using a cotton dummy by designing and manufacturing the electronic moxibustion using a heat-wire heater easy to control temperature and time. As a result, as for Gu-Gwan moxibustion, the maximum temperature on the surface of dummy was measured 41.6°C, and infrared sensor 42.7°C while the electronic moxibustion measured 44.3°C of thermocouple and 46.43°C of infrared sensor, showing higher thermal efficiency. Also, as a result of measuring temperature change in the depth of 0mm, 2mm, 4mm, 6mm and 10mm for the same period of time, the electronic moxibustion showed better thermal conductivity than Gu-Gwan moxibustion.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Chen, C.J., Yu, H.S.: Acupucture treatment of urticaria. Arch. Dermatol. 34, 1397–1399 (1998)
Shin, K.R., Kwak, S.A., Lee, J.B., Yi, H.R.: The effectiveness of hand acupuncture and moxibustion in decreasing pain and coldness in Korea women who have had hysterectomy: a pilot study. Appl. Nurs. Res. 19, 22–30 (2006)
Marquardt, M.F., Pollak, S., Schmidt, U.: Cigarette burns in forensic medicine. Forensic Science International 176, 200–208 (2008)
Bensoussan, A., Myers, S.P., Carlton, A.L.: Risks Associated With the Practice of Traditional Chinese Medicine. Arch. Fam. Med. 9, 1071–1078 (2000)
Alster, T.S., Tanzi, E.: Improvement of Neck and Cheek Laxity With a Nonablative Radiofrequency Device. A Lifting Experience. Dermatol. Surg. 30, 503–507 (2004)
Dupuy, D.E., Smith, W.M., Abbott, G.F., Di Petrillo, T.: Clinical Applications of Radio-Frequency Tumor Ablation in the Thorax. Radio Graphics 22, s259–s269 (2002)
Rhim, H., Yoon, K.H., Lee, J.M., Cho, Y.K., Cho, J.S., Kim, S.H., Lee, W.J., Lim, H.K., Nam, G.J., Han, S.S., Kim, Y.H., Park, C.M., Kim, P.N., Byun, J.Y.: Major Complications after Radio-Frequency Thermal Ablation of Hepatic Tumors: Spectrum of Imaging Findings. Radio Graphics 23, 123–134 (2003)
Carcinoma: Early Clinical Experience. Radiology 217, 665–672 (2000)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer Science+Business Media Dordrecht
About this paper
Cite this paper
Cheon, MW. et al. (2012). Comparison of Temperature in the Deep Part of the Dummy by the Electronic Moxibustion and the Gu-Gwan Moxibustion. In: Park, J., Kim, J., Zou, D., Lee, Y. (eds) Information Technology Convergence, Secure and Trust Computing, and Data Management. Lecture Notes in Electrical Engineering, vol 180. Springer, Dordrecht. https://doi.org/10.1007/978-94-007-5083-8_6
Download citation
DOI: https://doi.org/10.1007/978-94-007-5083-8_6
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-007-5082-1
Online ISBN: 978-94-007-5083-8
eBook Packages: EngineeringEngineering (R0)