Surface Electrocardiogram in Ventricular Pre-excitation: How Reliable Is It To Locate the Site of Accessory Pathway?

  • Conference paper
Cardiac Arrhythmias 1995

Abstract

It is estimated that about 3–4/1000 individuals are born with accessory pathway. These patients may have anterograde manifest conduction and hence show ventricular pre-excitation with short PR interval and delta waves (WPW electrocardiographic pattern). In some cases the accessory pathway may be concealed, manifesting only retrograde conduction over this tract. If so, the electrocardiogram is normal. In 5%–10% of series, multiple accessory pathways have been described.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Rosenbaum F, Hect H, Wilson F, Johnston F (1945) The potential variation of the thorax and the oesophagus in anomalous atrioventricular excitation ( Wolff-Parkinson-White Syndrome ). Am Heart J 29: 281–288

    Article  Google Scholar 

  2. Milstein S, Sharma AD, Guiraudon GM, Klein GJ (1987) An algorithm for the electrocardiographic localization of accessory pathways in the Wolff-Parkinson-White Syndrome. Pace 10: 555–563

    Article  PubMed  CAS  Google Scholar 

  3. Fitzpatrick AP, Gonzales RP, Lesh MD, Modin GW, Lee RJ, Scheinman MM (1994) New algorithm for localization of accessory atrioventricular connections using a baseline electrocardiogram. J Am Coll Cardiol 23: 107–116

    Article  PubMed  CAS  Google Scholar 

  4. Rodriguez L, Smeet J, De Chillou C et al (1993). The 12-lead electrocardiogram in midseptal, anteroseptal, posteroseptal and right free wall accessory pathways. Am J Cardiol 72: 1274–1280

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1996 Springer-Verlag Italia, Milano

About this paper

Cite this paper

Piccolo, E., Delise, P., Themistoclakis, S. (1996). Surface Electrocardiogram in Ventricular Pre-excitation: How Reliable Is It To Locate the Site of Accessory Pathway?. In: Raviele, A. (eds) Cardiac Arrhythmias 1995. Springer, Milano. https://doi.org/10.1007/978-88-470-2223-2_33

Download citation

  • DOI: https://doi.org/10.1007/978-88-470-2223-2_33

  • Publisher Name: Springer, Milano

  • Print ISBN: 978-3-540-75012-3

  • Online ISBN: 978-88-470-2223-2

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics