Abstract
Computed tomography enterography (CTEG) is a focused CT scan examination of the small intestine that combines the advantages of isotropic, thin-section multiplanar CT; the large volumes of neutral-density oral contrast; and rapid administration of intravenous contrast. Oral contrast agents such as 0.1% barium, polyethylene glycol (PEG) and methylcellulose contain additives that inhibit fluid reabsorption and allow maximal bowel distention. Intravenous contrast is injected at the “enteric phase” (about 45 s) to provide maximum wall enhancement against the neutral-density lumen (0–30 HU) [1]. Pharmacological manipulation to interrupt small-bowel spasm and encourage gastric emptying is commonly used, including glucagon and metoclopramide, respectively. The indications for CTEG include Crohn’s disease and other enteritides, obscure gastrointestinal bleeding (OGIB), detection of intestinal masses, and sprue. A prospective blinded comparison of CTEG with wireless capsule endoscopy (WCE) using clinical consensus as the gold-standard found similar sensitivities (82 vs. 83%) for active small-bowel Crohn’s disease, but CTEG was far more specific than WCE (89 vs. 53%).
Keywords
- Bowel Distention
- Wireless Capsule Endoscopy
- Oral Contrast Agent
- Obscure Gastrointestinal Bleeding
- Compute Tomography Enterography
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
This is a preview of subscription content, access via your institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Colombel JF, Solem CA, Sandborn WJ et al (2006) Quantitative measurement and visual assessment of ileal Crohn’s disease activity by computed tomography enterography: correlation with endoscopic severity and C reactive protein. Gut 55:1561–1567
Paulsen SR, Huprich JE, Hara AK (2007) CT enterography: Noninvasive evaluation of Crohn’s Disease and obscure gastrointestinal bleed. Radiol Clin N Am 45:303–315
Huprich JE, Fletcher JG (2009) CT enterography: Principles, technique and utility in Crohn’s disease. Eur J Radiol 69:393–397
Dave-Verma H, Moore S, Singh A et al (2008) Computed tomographic enterography and enteroclysis: pearls and pitfalls. Curr Probl Diagn Radiol 37:279–287
Wold PB, Fletcher JG, Johnson CD et al (2003) Assessment of small bowel Crohn disease: Noninvasive peroral CT enterography compared with other imaging methods and endoscopyfeasibility study. Radiology 229:275–281
Vogel J, Moreira A, Baker M (2007) CT enterography for Crohn’s disease: Accurate preoperative diagnostic imaging. Dis Colon Rectum 50:1761–1769
Solem CA, Loftus Jr EV, Fletcher JG et al (2008) Small-bowel imaging in Crohn’s disease: a prospective, blinded, 4-way comparison trial. Gastrointest Endosc 68:255–266
Hara AK, Alam S, Heigh RI et al (2008) Using CT enterography to monitor Crohn’s disease activity: a preliminary study. AJR 190:1512–1516
Higgins PDR, Caoli E, Zimmerman M et al (2007) Computed tomographic enterography adds information to clinical management in small bowel Crohn’s disease. Inflamm Bowel Dis 13:262–268
Bruining DH, Siddicki H, Fletcher JG (2008) Clinical benefit of CT enterography in suspected or established Crohn’s disease: impact on patient management and physician level of confidence. Gastroenterology S1211
Singh V, Alexander JA (2008) The evaluation and management of obscure and occult gastrointestinal bleeding. Abdom Imaging 34:311–319
Huprich JE, Fletcher JG, Alexander JA (2008) Obscure gastrointestinal bleeding: Evaluation with 64-section multiphase CT enterography — initial experience. Radiology 246:562–571
Brenner DJ, Hall EJ (2007) Computed tomography — an increasing source of radiation exposure. N Engl J Med 357:2277–2284
Hara AK, Walker FB, Silva AC, Leighton JA (2009) Preliminary estimate of triphasic CT enterography performance in hemodynamically stable patients with suspected gastrointestinal bleeding. AJR 193:1252–1260
Postgate A, Despott E, Burling D et al (2008) Significant small-bowel lesions detected by alternative diagnostic modalities after negative capsule endoscopy. Gastrointest Endosc 68:1209–1214
Voderholzer WA, Beinhoelzl J, Rogalla P et al (2005) Small bowel involvement in Crohn’s disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis. Gut 54:369–373
Voderholzer WA, Ortner M, Rogalla P et al (2003) Diagnostic yield of wireless capsule enteroscopy in comparison with computed tomography enteroclysis. Endoscopy 35:1009–1014
Fillipone A, Cianci R, Milano A et al (2008) Obscure gastrointestinal bleeding and small bowel pathology) comparison between wireless capsule endoscopy and multidetector-row CT enteroclysis. Abdom Imaging 33:398–406
Romano S, De Lutio E, Rollandi GA et al (2005) Multidetector computed tomography enteroclysis (MDCT-E) with neutral enteral and IV contrast enhancement in tumor detection. Eur Radiol 15:1178–1183
Maglinte DDT, Lappas JC, Heitcamp DE et al (2003) Technical refinements in enteroclysis. Radiol Clin North Am 41: 213–229
Boudiaf M, Jaff A, Soyer P et al (2004) Small-bowel diseases: Prospective evaluation of multi-detector row helical CT enteroclysis in 107 consecutive patients. Radiology 233:338–344
Pilleul F, Penigaud M, Milot L et al (2006) Possible smallbowel neoplasms: contrast-enhanced and water-enhanced multidetector CT enteroclysis. Radiology 241:796–801
Walsh D, Bender G, Timmons H (1998) Comparison of computed tomography enteroclysis and traditional computed tomography in the setting of suspected partial small bowel obstruction. Emerg Radiol 5:29–37
Mannudeep K, Rizzo SMR, Novelline RA (2005) Technologic innovations in computer tomography dose reduction: implications in emergency settings. Emergency Radiology 11:127–128
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer Verlag Italia
About this chapter
Cite this chapter
Gollub, M.J. (2010). Small-Bowel Imaging: Pitfalls in Computed Tomography Enterography/Enteroclysis. In: Hodler, J., Zollikofer, C.L., Von Schulthess, G.K. (eds) Diseases of the Abdomen and Pelvis 2010–2013. Springer, Milano. https://doi.org/10.1007/978-88-470-1637-8_4
Download citation
DOI: https://doi.org/10.1007/978-88-470-1637-8_4
Publisher Name: Springer, Milano
Print ISBN: 978-88-470-1636-1
Online ISBN: 978-88-470-1637-8
eBook Packages: MedicineMedicine (R0)