Riassunto
Il sottotitolo di questo capitolo potrebbe anche essere “Come i dettagli possono influenzare il successo della NIV”, perché a volte piccoli accorgimenti o avvertenze determinano la riuscita o meno di un tentativo di ventilazione.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Letture consigliate
Borel JC, Sabil A, Janssens JP et al (2009) Intentional leaks in industrial masks have a significant impact on efficacy of bilevel noninvasive ventilation: a bench test study. Chest 135(3):669–677
Ceriana P, Navalesi P, Rampulla C et al (2003) Use of bronchodilators during non-invasive mechanical ventilation. Monaldi Arch Chest Dis 59(2):123–127
Chatmongkolchart S, Schettino GP, Dillman C et al (2002) In vitro evaluation of aerosol bronchodilator delivery during non-invasive positive pressure ventilation: effect of ventilator settings and nebulizer position. Crit Care Med 30(11):2515–2519
Craven DE, Goularte TA, Make BJ (1984) Contaminated condensate in mechanical ventilator circuit. A risk factor for nosocomial pneumonia? Am Rev Respir Dis 129(4):625–628
Dhand R, Tobin MJ (1997) Inhaled bronchodilator therapy in mechanically ventilated patients. Am J Respir Crit Care Med 156(1):3–10
Ferguson GT, Gilmartin M (1995) CO2 rebreathing during BiPAP ventilatory asssitance. Am J Respir Crit Care Med 151(4):1126–1135
Hill NS, Carlisle C, Kramer NR (2002) Effect of a nonrebreathing exhalation valve on long-term nasal ventilation using a bilevel device. Chest 122(1):84–91
Jaber S, Chanques G, Matecki S et al (2002) Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during non-invasive ventilation. Intensive Care Med 28(11):1590–1594
Lellouche F, Maggiore SM, Deye N et al (2002) Effect of the humidification device on the work of breathing during noninvasive ventilation. Intensive Care Med 28(11):1582–1589
Lofaso F, Brochard L Touchard D et al (1995) Evaluation of carbon dioxide rebreathing during pressure support ventilation with airway management system (BiPAP) devices. Chest 108(3):772–778
Lofaso F, Aslanian P, Richard JC et al (1998) Expiratory valves used for home devices: experimental and clinical comparison. Eur Respir J 11(6):1382–1388
Massie CA, Hart RW, Peralez K, Richards GN (1999) Effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure. Chest 116(2):403–408
Nava S, Karakurt S, Rampulla C et al (2001) Salbutamol delivery during non-invasive mechanical ventilation in patients with chronic obstructive pulmonary disease: a randomized, controlled study. Intensive Care Med 27(10):1627–1635
Nava S, Cirio S, Fanfulla F (2008) Comparison of two humidification systems for long-term noninvasive mechanical ventilation. Eur Respir J 32(2):460–464
Rakotonanahary D, Pelletier-Fleury N, Gagnadoux F, Fleury B (2001) Predictive factors for the need for additional humidification during nasal continuous positive airways pressure therapy. Chest 119(2):460–465
Thys F, Liistro G, Dozin O et al (2002) Determinants of FiO2 with oxygen supplementation during noninvasive two-level positive pressure ventilation. Eur Respir J 19(4): 653–657
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer-Verlag Italia
About this chapter
Cite this chapter
Nava, S., Fanfulla, F. (2010). Trucchi e trappole della ventilazione non invasiva. In: Ventilazione meccanica non invasiva. Springer, Milano. https://doi.org/10.1007/978-88-470-1548-7_15
Download citation
DOI: https://doi.org/10.1007/978-88-470-1548-7_15
Publisher Name: Springer, Milano
Print ISBN: 978-88-470-1547-0
Online ISBN: 978-88-470-1548-7
eBook Packages: MedicineMedicine (R0)