Abstract
The advent of technology has made great leaps from the conventional methods of disease treatment. Nowadays, there has been a great shift toward continual monitoring, early detection, and prevention of diseases. Complimenting to this is the innovation of wearable medical devices. Wearable medical devices are portable electronic devices embedded in the user’s outfit. This not only facilitates faster treatment but also ensures comfortable diagnostic environment for the patient. ECG and PPG signals are of prime importance when the continual monitoring of the cardiac state of the patient is concerned. Hence, using a wearable medical device, the biomedical signals can be easily obtained and interpreted. This paper discusses a method to measure blood pressure from ECG and PPG signals acquired from the device. To realize the method, various algorithms for the implementation were coded in MATLAB. The algorithm was tested on records taken from PhysioNet ATM and a private database.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Pan, J., Tompkins, W.J.: A real time QRS detection algorithm. IEEE Trans. Biomed. Eng. 32, 230–236 (1985)
Rezk, S., Join, C., El Asmi, S.: An algebraic derivative-based method for R wave detection. In: 19th European signal processing conference (2011)
Sornmo, L., Laguna, P.: Electrocardiogram signal processing. Wiley Encyclopedia of Biomedical Engineering (2006)
Smilyjeya Jothi, E., Preetha, S.: Detection of peak and ONSET of PPG signal. Int. J. Adv. Sci. Tech. Res., ISSN 1(3)2249–9954, Jan–Feb 2013
Rabiner, Lawrence R., Gold, Bernard: Theory and Applications of Digital Signal Processing, 15th edn. Prentice Hall of India, New Delhi (2001)
Acknowledgments
We would like to express our profound gratitude and deep regards to our guide Mr. Rajesh Kannan Megalingam for his exemplary guidance, cordial support, and valuable information. We also extend our thanks to Dr. G Jayachandran Nair, Distinguished Professor of ECE Department, for the technical support he provided in different stages of progress. His expertise has helped us simplify much of the complex concepts.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer India
About this paper
Cite this paper
Megalingam, R.K. et al. (2015). Wearable Medical Devices in Preventive Health Care: Cuffless Blood Pressure Measurement. In: Jain, L., Patnaik, S., Ichalkaranje, N. (eds) Intelligent Computing, Communication and Devices. Advances in Intelligent Systems and Computing, vol 308. Springer, New Delhi. https://doi.org/10.1007/978-81-322-2012-1_80
Download citation
DOI: https://doi.org/10.1007/978-81-322-2012-1_80
Published:
Publisher Name: Springer, New Delhi
Print ISBN: 978-81-322-2011-4
Online ISBN: 978-81-322-2012-1
eBook Packages: EngineeringEngineering (R0)