ICoRD'13 pp 365-375 | Cite as

Force JND for Right Index Finger Using Contra Lateral Force Matching Paradigm

  • M. S. Raghu Prasad
  • Sunny Purswani
  • M. Manivannan
Conference paper
Part of the Lecture Notes in Mechanical Engineering book series (LNME)

Abstract

The paper aims at deriving the Just Noticeable Difference (JND) for force magnitude recognition between left and right index finger of human hand. The experiment involves establishment of an internal reference stimulus, using the left index fingers of the hand, by the subject, which is perceived and matched under contra-lateral force matching paradigm. A combination of virtual environment and a force sensor was used to derive the just noticeable difference for index-finger force application. Six voluntary healthy young adult subjects in the age group of 22–30 years were instructed to produce reference forces by left index finger and to reproduce the same amount of force by the right index finger, when the subjects were confident enough of matching same amount of force, the force values of the both the left and right index finger were recorded simultaneously for 5 s at 10 Hz. Five different trials were conducted for different force levels ranging from 2 to 5 N. The percentage real JND and absolute JND were derived for all the subjects. It was found that the Force-JND obtained was approximately 10 % across all subjects. Results also show that subjects tend to underestimate force at high force levels and overestimate at low force levels. The results obtained can be used as basic building block for the calibration of virtual reality based minimally invasive surgery related tasks and force based virtual user interfaces ranging from touch pad to assistive tools.

Keywords

Just noticeable difference Contra lateral matching Force matching Finger force perception Visual cognition 

References

  1. 1.
    Weber EH (1978) The sense of touch. Academic Press for Experimental Psychology Society, LondonGoogle Scholar
  2. 2.
    Tan HZ, Mandayam BE, Srinivasan A, Cheng B (1994) Human factors for the design of force-reflecting haptic interfaces. Dyn Syst Control DSC–vol 55–1Google Scholar
  3. 3.
    Pang X, Tan HZ, Durlach NI (1991) Manual discrimination of force using active finger motion. Percept Psychophys 49(6):531–540Google Scholar
  4. 4.
    Jones LA (1989) Matching forces: constant errors and differential thresholds Perception 18(5):681–687Google Scholar
  5. 5.
    Brodie E, Ross H (1984) Sensorimotor mechanisms in weight discrimination. Attention Percept Psychophys 36(5):477–481CrossRefGoogle Scholar
  6. 6.
    Greenspan JD (1984) A comparison of force and depth of skin indentation upon psychophysical functions of tactile intensity. Somatosens Res 2(1):3348Google Scholar
  7. 7.
    Goodwin AW, Wheat HE (1992) Magnitude estimation of contact force when objects with different shapes are applied passively to the finger pad. Somatosens Mot Res 9(4):339–344CrossRefGoogle Scholar
  8. 8.
    Srinivasan MA, Chen JS (1993) Human performance in controlling normal forces of contact with rigid objects. Adv Robot Mechatron Haptic Interfaces DSC-vol 49, ASMEGoogle Scholar
  9. 9.
    Gandevia SC, McCloskey DI (1977) Effects of related sensory inputs on motor performances in man studied through changes in perceived heaviness. J Physiol 272(3):653–672Google Scholar
  10. 10.
    Gandevia SC, McCloskey DI (1977) Changes in motor commands, as shown by changes in perceived heaviness, during partial curarization and peripheral anaesthesia in man. J Physiol 272:673–689Google Scholar
  11. 11.
    Cafarelli E, Bigland-Ritchie B (1979) Sensation of static force in muscles of different length. Exp Neurol 65(3):511–25Google Scholar
  12. 12.
    Kilbreath SL, Refshauge K, Gandevia SC, (1997) Differential control of the digits of the human hand: evidence from digital anaesthesia and weight matching. Exp Brain Res 117(3):507–511Google Scholar
  13. 13.
    Jones LA (2003) Perceptual constancy and the perceived magnitude of muscle forces. Exp Brain Res 151(2):197–203Google Scholar
  14. 14.
    Park W-H, Leonard CT, Li S (2008) Finger force perception during ipsilateral and contralateral force matching tasks. Exp Brain Res 189:301–310CrossRefGoogle Scholar
  15. 15.
    Flórez1 JA, Velásque A (2010) Calibration of force sensing resistors (FSR) for static and dynamic applications. ANDESCON, IEEE, 15–17 Sept 2010Google Scholar
  16. 16.
    Jones LA, Piateski E (2006) Contribution of tactile feedback from the hand to the perception of force. Exp Brain Res 168(1–2):298–302Google Scholar

Copyright information

© Springer India 2013

Authors and Affiliations

  • M. S. Raghu Prasad
    • 1
  • Sunny Purswani
    • 1
  • M. Manivannan
    • 1
  1. 1.Haptics Lab, Biomedical Engineering Group, Department of Applied MechanicsIIT MadrasChennaiIndia

Personalised recommendations