The Principle of Doppler Ultrasound

  • Chapter
Portal Hypertension
  • 497 Accesses

Abstract

The Doppler effect is a well-known phenomenon, an example of which is the siren from a moving vehicle is perceived as different tones when approaching and leaving the listener. The Doppler effect in the case of ultrasound was discovered in 1957 and has since been applied to the measurement of blood flow [1,2]. The combination of Doppler flowmeter with real time B-mode imaging has made it possible to measure blood flow in deep-seated blood vessels [3,4]. Circulation and hemodynamics of the liver and splanchnic organs have been investigated using the so-called Doppler ultrasound (Doppler duplex ultrasound system) [5–8].

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Baker DW (1970) Pulsed ultrasonic Doppler blood flow sensing. IEEE Trans Sonics Ultrasonics SU-17: 170–185

    Article  Google Scholar 

  2. Satomura S (1957) Ultrasonic Doppler method for the inspection of cardiac function. J Acoust Soc Am 29: 1181

    Article  Google Scholar 

  3. Taylor KJW, Burns PN, Woodcock JP, Wells PNT (1985) Blood flow in deep abdominal and pelvic vessels: Ultrasonic pulsed Doppler analysis. Radiology 154: 487–493

    PubMed  CAS  Google Scholar 

  4. Wetzner SW, Kiser LC, Bezreh JS (1984) Duplex ultrasound imaging: Vascular applications. Radiology 150: 507–514

    PubMed  CAS  Google Scholar 

  5. Moriyasu F, Nishida O, Ban N, Nakamura T, Miura K, Sakai M, Miyake T, Uchino H (1986) Measurement of portal vascular resistance in patients with portal hypertension. Gastroenterology 90: 710–717

    PubMed  CAS  Google Scholar 

  6. Moriyasu F, Nishida O, Ban N, Nakamura T, Sakai M, Miyake T, Uchino H (1986) “Congestion index” of the portal vein. AJR 146: 735–739

    Article  PubMed  CAS  Google Scholar 

  7. Ohnishi K (1988) Doppler flowmetry and portal hypertension. Gastroenterology 94: 1242–1243

    PubMed  CAS  Google Scholar 

  8. Okazaki K, Miyazaki M, Ohnishi S, Ito K (1986) Effects of food intake and various intrinsic hormones on portal blood flow in patients with liver cirrhosis demonstrated by pulsed Doppler with the Octoson. Scand J Gastroenterol 21: 1029–1038

    Article  PubMed  CAS  Google Scholar 

  9. Hatle L, Angelsen B (1982) Doppler ultrasound in cardiology. Lea and Febiger, Philadelphia, PA pp 32-57

    Google Scholar 

  10. Taylor KJW, Burns PN, Wells PNT (1988) Clinical applications of Doppler ultrasound. Raven, New York, pp 1-76

    Google Scholar 

  11. Hatle L, Angelsen B (1982) Doppler ultrasound in cardiology. Lea and Febiger, Philadelphia, pp 224-227

    Google Scholar 

  12. Dauzat M, Layrargues GP (1989) Portal vein blood flow measurements using pulsed Doppler and electromagnetic flowmetry in dogs: A comparative study. Gastroenterology 96: 913–919

    PubMed  CAS  Google Scholar 

  13. Gill RW (1979) Pulsed Doppler with B-mode imaging for quantitative blood flow measurement. Ultrasound Med Biol 5: 223–235

    Article  PubMed  CAS  Google Scholar 

  14. Gill RW (1979) Performance of the mean frequency Doppler demodulator. Ultrasound Med Biol 5: 237–247

    Article  PubMed  CAS  Google Scholar 

  15. Moriyasu F, Ban N, Nishida O, Nakamura T, Miyake T, Uchino H, Kanematsu Y, Koizumi S (1986) Clinical application of an ultrasonic duplex system in the quantitative measurement of portal blood flow. JCU 14: 579–588

    PubMed  CAS  Google Scholar 

  16. Nakamura T, Moriyasu F, Ban N, Nishida O, Tamada T, Kawasaki T, Sakai M, Uchino H (1989) Quantitative measurement of abdominal arterial blood flow using image-directed Doppler ultrasonography: Superior mesenteric, splenic, and common hepatic arterial blood flow in normal adults. JCU 17: 261–268

    PubMed  CAS  Google Scholar 

  17. Burns P, Taylor KJW, Blei AT (1987) Doppler flowmetry and portal hypertension. Gastroenterology 92: 824–826

    PubMed  CAS  Google Scholar 

  18. Ohnishi K, Saito M, Koen H, Nakayama T, Nomura F, Okuda K (1985) Pulsed Doppler flow as a criterion of portal venous velocity: comparison with cineangiographic measurements. Radiology 154: 495–498

    PubMed  CAS  Google Scholar 

  19. Moriyasu F, Nakamura T, Nishida O, Ban N, Uchino H (1958) Analysis of velocity profile in canine portal blood flow using an 8MHz pulsed Doppler flowmeter. Jpn J Med Ultrasonics 12: 328–334

    Google Scholar 

  20. Evans JM, Skidmore R, Luckman NP, Wells PNT (1989) A new approach to the noninvasive measurement of cardiac output using an annular array Doppler technique-I. Theoretical considerations and ultrasonic fields. Ultrasound Med Biol 15: 169–178

    Article  PubMed  CAS  Google Scholar 

  21. Hottinger CF, Meindl JD (1979) Blood flow measurement using the attenuation-compensated volume flowmeter. Ultrason Imaging 1: 1–15

    PubMed  CAS  Google Scholar 

  22. Evans JM, Skidmore R, Baker JD, Wells PNT (1989) A new approach to the noninvasive measurement of cardiac output using an annular array Doppler technique-II. Practical implementation and results. Ultrasound Med Biol 15: 179–187

    Article  PubMed  CAS  Google Scholar 

  23. Gill RW (1985) Measurement of blood flow by ultrasound: accuracy and sources of error. Ultrasound Med Biol 11: 625–641

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1991 Springer Japan

About this chapter

Cite this chapter

Moriyasu, F. (1991). The Principle of Doppler Ultrasound. In: Okuda, K., Benhamou, JP. (eds) Portal Hypertension. Springer, Tokyo. https://doi.org/10.1007/978-4-431-68361-2_12

Download citation

  • DOI: https://doi.org/10.1007/978-4-431-68361-2_12

  • Publisher Name: Springer, Tokyo

  • Print ISBN: 978-4-431-68363-6

  • Online ISBN: 978-4-431-68361-2

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics