Skip to main content

Second Type of Linear Motor-Driven Total Artificial Heart

  • Conference paper
Book cover Heart Replacement

Summary

We evaluated the performance of the first type of linear motor-driven total artificial heart (TAH) in an acute animal experiment reported previously. Artificial circulation in an adult sheep was maintained for only 2 h, indicating that the linear motor needed more powerful thrust. A second type of linear motor-driven TAH was constructed, on the basis of the information obtained from the acute animal experiment. The second TAH has a maximum static thrust of 146 N, achieved by enlarging the thrust action area in the linear motor. The mass of the TAH is 1.9 kg, and the volume TAH is 560mL; this size is suitable for implantation in a human subject weighing 80 kg. The second TAH provides a left pump flow rate of 7.2 L/min at a pumping rate of 120 bpm in a mock circulatory system.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Yamada H, Yamaguchi M, Karita M, Matsuura Y, Fukunaga S (1994) Acute animal experiment using a linear motor-driven total artificial heart. J Magn Soc Jpn 18: 519–524

    Article  Google Scholar 

  2. Shiomi H (1982) Guide for reliability technology (in Japanese). Maruzen, Tokyo, pp 106–113, 248–251

    Google Scholar 

  3. Yamaguchi M, Yamada H (1994) Reliability evaluation of a linear pulse motor for a total artificial heart driving. Trans IEEJ 114-D: 94–100

    Google Scholar 

  4. Yamaguchi M, Yamada H, Wakiwaka H, Karita M (1993) System estimation of linear pulse motor-driven artificial heart. In: Akutsu T, Koyanagi H (eds) Heart replacement Artificial heart 4. Springer, Tokyo Berlin Heidelberg New York, pp 127–132

    Google Scholar 

  5. JIS handbook, machine elements (in Japanese) (1992) JSA, Tokyo pp 1066–1075

    Google Scholar 

  6. LM system catalog, 200 (in Japanese) (1993) THK, Tokyo, p A309

    Google Scholar 

  7. Magnet wires catalog, IAPRO (in Japanese) (1992) Totoku, Tokyo, p 19

    Google Scholar 

  8. Product data sheet, PDS81 (in Japanese) (1989) Loctite Japan, Yokohama, p 4

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1996 Springer Japan

About this paper

Cite this paper

Yamada, H. et al. (1996). Second Type of Linear Motor-Driven Total Artificial Heart. In: Akutsu, T., Koyanagi, H. (eds) Heart Replacement. Springer, Tokyo. https://doi.org/10.1007/978-4-431-67020-9_14

Download citation

  • DOI: https://doi.org/10.1007/978-4-431-67020-9_14

  • Publisher Name: Springer, Tokyo

  • Print ISBN: 978-4-431-67022-3

  • Online ISBN: 978-4-431-67020-9

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics