Abstract
Since the development of cardiac surgery and myocardial protection, open heart surgery has been carried out for severely ill patients with heart disease. Sorjie of these patients need mechanical circulatory assistance. Intra-aortic balloon pumping (IABP), V-A bypass, and artificial assist devices have been used according to the severity of heart failure, and satisfactory results have been obtained.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Okada M, Tsukube T, Mukai T, Kashem MA (1995) Role of dynamic cardiomyoplasty for pump failure. Artif Organs Today 4:183–189
Tsukube T, Okada M, Mukai T, Kashem MA (1994) Effect of dynamic cardiomyoplasty on coronary blood flow. J Thorac Cardiovasc Surg 108:609–615
Sibley D, Millar H, Hartley C, Whitlow P (1986) Sub-selective measurement of coronary blood flow velocity using a steerable Doppler catheter. J Am Coll Cardiol 8:1332–1340
Serruys PW, Mario CD, Meneveau N, Jaegere PD, Feyter PJD, Emanuelsson H (1993) Intra-coronary pressure and flow velocity with sensor-tip guide wire: a new methodologic approach for assessment of coronary hemodynamics before and after coronary interventions. Am J Cardiol 71:41D–53D
Chilian W, Layne S (1990) Ultrasonic measurement of coronary blood flow. Springer, Tokyo, pp 55–72
Doucette JW, Corl PD, Payne HM, Flynn AE, Goto M, Nassi M, Segal J (1992) Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation 85:1899–1911
Okada M, Mukai T, Tsukube T (1993) Dynamic cardio-myoplasty as a circulatory assist. Cardiac pacing and electrophysiology today, Simul International, Tokyo, pp 513–519
Carpentier A, Chachquies J (1985) Myocardial substitution with a stimulated muscle: first successful clinical case (letter). Lancet 1:1267
Kantrowitz A, McKinnon W (1959) The experimental use of the diaphragm as an auxiliary myocardium. Surg Forum 9:266–268
Olsson R, Bunger R, Spaan J (1991) Coronary circulation: the heart and cardiovascular system, 2nd edn. Raven, New York, pp 1393–1425
Nakamura K, Glenn W (1964) Graft of diaphragm as a functioning substitute for myocardium: an experimental study. J Surg Res 4:435–439
Jatene AD, Moreira LFP, Stolf NAG, Bocci EA, Seferian P Jr, Fernandes PMP, Abensur H (1991) Left ventricular function changes after cardiomyoplasty in patients with dilated cardiomyopathy. J Thorac Car-diovasc Surg 102:132–139
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1998 Springer-Verlag Tokyo
About this paper
Cite this paper
Okada, M., Toyoda, Y., Mukai, T., Kashem, M.A., Tsukube, T. (1998). The Effect of Cardiomyoplasty on Coronary Blood Flow and Diastolic Dimension of the Left Ventricle. In: Akutsu, T., Koyanagi, H. (eds) Heart Replacement. Springer, Tokyo. https://doi.org/10.1007/978-4-431-65921-1_36
Download citation
DOI: https://doi.org/10.1007/978-4-431-65921-1_36
Publisher Name: Springer, Tokyo
Print ISBN: 978-4-431-65923-5
Online ISBN: 978-4-431-65921-1
eBook Packages: Springer Book Archive