Notes
- 1.
Scipione Riva-Rocci, italienischer Arzt, [Eckert, 2006]
- 2.
Nikolai Sergejewitsch Korotkow, russischer Arzt und Chirurg [Shevchenko and Tsitlik, 1996]
- 3.
PROCAM Score (EU), ESC-Heart-Score (USA), Framington Score u.a.
- 4.
Bei angenommener PWV von 5m/s und einem Laufweg von 1, 5m wĂ¼rde die rĂ¼cklaufende PW nach etwa 0, 3 sec eentreffen
- 5.
vgl. Abbildung und Erläuterung im Anhang D.1
- 6.
Vgl. Unterabschnitt 2.2.1
- 7.
Details hierzu finden sich in Chen et al. [1997], Fetics et al. [1999], Lehmann et al. [1998], Karamanoglu et al. [1995].
- 8.
IEM, Arteriograph u.a..
- 9.
[Douniama and Couronné, 2007], [Douniama et al., 2009], [Douniama et al., 2009b]
- 10.
Zhang [2003], Zhang [2005], Teng and Zhang [2006], Heather and Zhang [2006], Franchi et al. [1996], Meigas et al. [2001], Wippermann et al. [1995], Pitson et al. [1995], Chen et al. [2000], Allen and Murray [2002], Geddes et al. [1981], Kaniusas et al. [2006], Wong and Zhang [2004], Kerola et al. [1996], Ochiai et al. [1999], Chua and Heneghan [2006], Geddes et al. [1981], Chua and Heneghan [2006], Barschdorff and Erig [1998], Lane et al. [1983], Poon and Zhang [2005], Wong and Zhang [2005], Young et al. [1995], Payne et al. [2005], Pollak and Obrist [1983], Chua and Heneghan [2006]
- 11.
engl. Pulse Wave Velocity (PWV), entspricht der auf den Laufweg bezogenen PTT
- 12.
\({{\upsilon }_{pw}}=\sqrt{\frac{\Delta P}{\rho b\Delta V}}\), \(\Delta P\) Druckänderung, \(\Delta V\) Volumenänderung, \(\rho b\) Spezifische Dichte des Blutes (Quelle McDonalds et al. [2005])
- 13.
\({{\upsilon }_{pw}}=\sqrt{\frac{E{{h}_{\upsilon }}}{2\rho b{{r}_{\upsilon i}}V}}\), E Elastikmodul, \({{h}_{\upsilon }}\) die Dicke der arteriellen Wand, \({{r}_{\upsilon i}}\)der innere Radius der Arterie (Quelle McDonalds et al. [2005])
- 14.
Zhang [2003], Zhang [2005], Teng and Zhang [2006], Heather and Zhang [2006], Meigas et al. [2001], Pitson et al. [1995], Chen et al. [2000], Allen and Murray [2002], Geddes et al. [1981], Wong and Zhang [2004], Kerola et al. [1996], Ochiai et al. [1999], Geddes et al. [1981], Lane et al. [1983], Wong and Zhang [2005], Payne et al. [2005], Pollak and Obrist [1983]
- 15.
Sugawara et al. [2000], Almeder and Breitenecker [2001], Kaniusas et al. [2006], Shaltis et al. [2005], Nitzan et al. [1999], Heard et al. [2000], Young et al. [1995], Chua and Heneghan [2006]
- 16.
Almeder and Breitenecker [2001], McDonalds et al. [2005], Elter [2001]
- 17.
Kerola et al. [1996], Lane et al. [1983]
- 18.
Ochiai et al. [1999], Geddes et al. [1981], Pollak and Obrist [1983], Weltman et al. [1964], Nye [1964], Pollak and Obrist [1983]
- 19.
Heather and Zhang [2006], Wippermann et al. [1995], Geddes et al. [1981], Barschdorff and Erig [1998], Payne et al. [2005], Pollak and Obrist [1983]
- 20.
Franchi et al. [1996], Wippermann et al. [1995], Chen et al. [2000], Geddes et al. [1981], Sugawara et al. [2000], Heard et al. [2000], Geddes et al. [1981], Lane et al. [1983], Young et al. [1995], Payne et al. [2005], Pollak and Obrist [1983]
- 21.
Zhang [2003], Teng and Zhang [2006], Heather and Zhang [2006], Kerola et al. [1996], Heard et al. [2000], Barschdorff and Erig [1998],Poon and Zhang[2005], Wong and Zhang [2005]
- 22.
Zhang [2005], Teng and Zhang [2006], Kaniusas et al. [2006], Shaltis et al. [2005], Nitzan et al. [1999], Chua and Heneghan[2006]
- 23.
Zhang [2005], Chen et al. [2000], Lane et al. [1983], Wong and Zhang [2005], Chua and Heneghan [2006]
- 24.
Geddes et al. [1981], Payne et al. [2005], Pollak and Obrist [1983]
- 25.
Franchi et al. [1996], Wippermann et al. [1995], Kaniusas et al. [2006], Weltman et al. [1964], Nye [1964], Heard et al. [2000], Shaltis et al. [2005], Barschdorff and Erig [1998], Poon and Zhang [2005], Young et al. [1995]
- 26.
häufig am Unterarm des Patienten
- 27.
Anstelle der Auskultation wird in lauter Umgebung der Puls an der Radialisarterie auch abgetastet (Palpation)
- 28.
Applanation bezeichnet das Glätten der Arterie unter planarer Druckeinwirkung.
- 29.
Bauelement, welches den Piezoeffekt ausnutzt: Bei Einwirkung einer mechanischen Kraft wird eine elektrische Spannung erzeugt und umgekehrt bei Anlegen einer elektrischen Spannung eine mechanische Verformung.
- 30.
Unter den oberen Extremitäten versteht man die Arme und unter den unteren Extremitäten die Beine.
- 31.
Unter Extinktion wird hier nur die durch Absorption verursachte Schwächung der Intensitätverstanden. Die in biologischem Gewebe ausgeprägten Verluste aufgrund multipler Streuung werden nicht berĂ¼cksichtigt.
- 32.
Funktionell bedeutet, dass die Sauerstoffaufnahme in in den kleinsten BlutgefĂ¤ĂŸen der Lunge (Alveolen) nur mit dem reduzierten Hämoglobin Hb möglich ist. Andere Hämoglobinderivate wie Methämoglobin (MetHb) oder Carboxyhämoglobin {COHb) werden nicht berĂ¼cksichtigt. Die fraktionelle Sauerstoffsättigung hingegen bezieht diese Komponenten mit ein.
- 33.
Nach der ISO-Norm 9919 hat sich folgende Terminologie etabliert: Die pulsoximetrisch gemessene, funktionelle Sauerstoffsättigung wird mit SpO2und die nach Blutentnahme in vitro gemessene GrĂ¶ĂŸe mitS a O 2 bezeichnet.
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2013 Vieweg+Teubner Verlag | Springer Fachmedien Wiesbaden
About this chapter
Cite this chapter
Couronné, R. (2013). Stand der Wissenschaft und Technik. In: Erfassung der Pulswelle am Unterarm. Aktuelle Forschung Medizintechnik. Vieweg+Teubner Verlag, Wiesbaden. https://doi.org/10.1007/978-3-8348-2403-5_2
Download citation
DOI: https://doi.org/10.1007/978-3-8348-2403-5_2
Publisher Name: Vieweg+Teubner Verlag, Wiesbaden
Print ISBN: 978-3-8348-2402-8
Online ISBN: 978-3-8348-2403-5
eBook Packages: Medicine (German Language)