Skip to main content

Electroencephalography and Evoked Potentials: Technical Background

  • Chapter
  • First Online:
Clinical Neurophysiology in Disorders of Consciousness

Abstract

Information provided by neurophysiological investigations is of outstanding importance for clinical practice and research dealing with patients with disorders of consciousness. However, because most of these patients are treated in the intensive care unit (ICU), some related problems must be known. The ICU is an environment full of electrical devices prone to produce artifacts, and patients with disorders of consciousness are exposed to many different treatments that may interfere with electrical signals and their interpretation. It is therefore highly important that the electroencephalogram (EEG) and the different sorts of evoked potentials (EP) are acquired under good conditions and according to current recommendations. This chapter reviews the technical background necessary to illustrate how to acquire good EEG/EP signals in the ICU, and will also focus on some practical pitfalls.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 69.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 89.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Alvarez V, Sierra-Marcos A, Oddo M, Rossetti AO (2013) Yield of intermittent versus continuous EEG in comatose survivors of cardiac arrest treated with hypothermia. Crit Care 17:R190

    Article  PubMed Central  PubMed  Google Scholar 

  • American Clinical Neurophysiology Society (2006a) Guideline 6: a proposal for standard montages to be used in clinical EEG. J Clin Neurophysiol 23(2):111–117

    Google Scholar 

  • American Clinical Neurophysiology Society (2006b) Guideline 3: minimum technical standards for EEG recording in suspected cerebral death. J Clin Neurophysiol 23(2):97–104

    Google Scholar 

  • American Clinical Neurophysiology Society (2006c) Guideline 8: guidelines for recording clinical EEG on digital media. J Clin Neurophysiol 23(2):122–124

    Google Scholar 

  • American Clinical Neurophysiology Society (2008) Guideline 1: minimum technical requirements for performing clinical electroencephalography. J Clin Neurophysiol 23(2):86–91

    Google Scholar 

  • Chatrian GE, Bergamasco B, Bricolo A, Frost JD, Prior PF (1996) IFCN recommended standards for electrophysiologic monitoring in comatose and other unresponsive states. Report of an IFCN Committee. Electroencephalogr Clin Neurophysiol 99:103–22

    Article  CAS  PubMed  Google Scholar 

  • Claassen J, Jetté N, Chum F et al (2007) Electrographic seizures and periodic discharges after intracerebral hemorrhage. Neurology 69:1356–65

    Article  CAS  PubMed  Google Scholar 

  • Cruccu G, Aminoff MJ, Curio G et al (2008) Recommendations for the clinical use of somatosensory-evoked potentials. Clin Neurophysiol 119:1705–19

    Article  CAS  PubMed  Google Scholar 

  • Das RR, Lucey BP, Chou SH-Y et al (2009) The utility of conductive plastic electrodes in prolonged ICU EEG monitoring. Neurocrit Care 10:368–72

    Article  PubMed  Google Scholar 

  • Ebner A, Sciarretta G, Epstein CM, Nuwer M (1999) EEG instrumentation. In: Deuschl G, Eisen A (eds) Recommendations for the practice of clinical neurophysiology: guidelines of the International Federation of Clinical Neurophysiology. Elsevier B.V., Amsterdam/New York, pp 7–10

    Google Scholar 

  • Eggins BR (1993) Skin contact electrodes for medical applications. Analyst 118:439–42

    Article  CAS  PubMed  Google Scholar 

  • Fisch BJ (1999) The generator of the EEG. In: Fisch & Spehlmann’s EEG primer – basic principles of digital and analog EEG, Elsevier l. Elsevier Ltd, Amsterdam, pp 4–9

    Google Scholar 

  • Freye E (2005) Cerebral monitoring in the operating room and the intensive care unit – an introductory for the clinician and a guide for the novice wanting to open a window to the brain. Part II: sensory-evoked potentials (SSEP, AEP, VEP). J Clin Monit Comput 19:77–168

    Article  PubMed  Google Scholar 

  • Freye E and Levy J (2005) Cerebral monitoring in the operating room and the intensive care unit: an introductory for the clinician and a guide for the novice wanting to open a window to the brain. Part I: The electroencephalogram. J Clin Monit Comput; 19: 1–76.

    Google Scholar 

  • Guérit J-M (2005) Evoked potentials in severe brain injury. Prog Brain Res 150:415–26

    Article  PubMed  Google Scholar 

  • Guérit J-M, Fischer C, Facco E et al (1999) Standards of clinical practice of EEG and EPs in comatose and other unresponsive states. In: Deutschl G, Eisen A (eds) Recommendations for the practice of clinical neurophysiology: guidelines of the International Federation of Clinical Neurophysiology. Elsevier B.V., Amsterdam/New York, pp 119–31

    Google Scholar 

  • Herman ST (2013) Equipment for EEG acquisition and review. In: Laroche SM (ed) Handbook of ICU EEG monitoring. Demos Medi, New York, p 4

    Google Scholar 

  • Israel HP, Aminoff M, Nuwer MR, Starr A (1999) Short-latency auditory evoked potentials. In: Deuschl G, Eisen A (eds) Recommendations for the practice of clinical neurophysiology: Guidelines of the International Federation of Clinical Neurophysiology. Elsevier B.V., Amsterdam/New York, pp 69–77

    Google Scholar 

  • Claassen J, Mayer SA, Kowalski RG, Emerson RG, Hirsch LJ (2004) Detection of electrographic seizures with continuous EEG monitoring in critically ill patients. Neurology 62:1743–1748

    Google Scholar 

  • Karakis I, Montouris GD, Otis JAD et al (2010) A quick and reliable EEG montage for the detection of seizures in the critical care setting. J Clin Neurophysiol 27:100–5

    Article  PubMed  Google Scholar 

  • Klem GH, Lüders HO, Jasper HH, Elger C (1999) The ten-twenty electrode system of the International Federation. In: Deuschl G, Eisen A (eds) Recommendations for the practice of clinical neurophysiology: guidelines of the International Federation of Clinical Neurophysiology. Elsevier Science B.V., Amsterdam, pp 3–6

    Google Scholar 

  • Kolls BJ, Husain AM (2007) Assessment of hairline EEG as a screening tool for nonconvulsive status epilepticus. Epilepsia 48:959–65

    Article  PubMed  Google Scholar 

  • Kurtz P, Hanafy KA, Claassen J (2009) Continuous EEG monitoring: is it ready for prime time? Curr Opin Crit Care 15:99–109

    Article  PubMed  Google Scholar 

  • Lindgren C, Nordh E, Naredi S, Olivecrona M (2012) Frequency of non-convulsive seizures and non-convulsive status epilepticus in subarachnoid hemorrhage patients in need of controlled ventilation and sedation. Neurocrit Care 17:367–73

    Article  CAS  PubMed  Google Scholar 

  • Maugnière F, Allison T, Babiloni C et al (1999) Somatosensory evoked potentials. In: Deuschl G, Eisen A (eds) Recommendations for the practice of clinical neurophysiology: Guidelines of the International Federation of Clinical Neurophysiology. Elsevier B.V., Amsterdam/New York, pp 79–90

    Google Scholar 

  • Mezrow CK, Midulla PS, Sadeghi AM et al (1994) Evaluation of cerebral metabolism and quantitative electroencephalography after hypothermic circulatory arrest and low-flow cardiopulmonary bypass at different temperatures. J Thorac Cardiovasc Surg 107:1006–19

    CAS  PubMed  Google Scholar 

  • Misulis KE, Fakhoury T (2001a) Arm somatosensory evoked potentials performance. In: Misulis KE, Fakhoury T (eds) Spehlmann’s evoked potential primer, 3rd edn. Butterworth, Woburn, pp 91–5

    Google Scholar 

  • Misulis KE, Fakhoury T (2001b) Auditory evoked potentials performance. In: Misulis KE, Fakhoury T (eds) Spehlmann’s evoked potential primer, 3rd edn. Butterworth, Woburn, pp 37–44

    Google Scholar 

  • Moura LMVR, Shafi MM, Ng M, et al (2014) Spectrogram screening of adult EEGs is sensitive and efficient. Neurology 83:56–64.

    Google Scholar 

  • Ney JP, van der Goes DN, Nuwer MR, Nelson L, Eccher MA (2013) Continuous and routine EEG in intensive care: utilization and outcomes, United States 2005–2009. Neurology 81:1–7

    Article  Google Scholar 

  • Rossetti AO, Oddo M, Logroscino G, Kaplan PW (2010) Prognostication after cardiac arrest and hypothermia a prospective study. Ann Neurol 67:301–7

    PubMed  Google Scholar 

  • Rossetti AO, Carrera E, Oddo M (2012) Early EEG correlates of neuronal injury after brain anoxia. Neurology 78:796–862

    Article  CAS  PubMed  Google Scholar 

  • Stecker MM, Cheung AT, Pochettino A et al (2001) Deep hypothermic circulatory arrest: I. Effects of cooling on electroencephalogram and evoked potentials. Ann Thorac Surg 71:14–21

    Article  CAS  PubMed  Google Scholar 

  • Tzovara A, Rossetti AO, Spierer L et al (2013) Progression of auditory discrimination based on neural decoding predicts awakening from coma. Brain 136:81–9

    Article  PubMed  Google Scholar 

  • Young GB (2000) The EEG in coma. J Clin Neurophysiol 17:473–85

    Article  CAS  PubMed  Google Scholar 

  • Young GB, Kreeft JH, McLachlan RS, Demelo J (1999) EEG and clinical associations with mortality in comatose patients in a general intensive care unit. J Clin Neurophysiol 16:354–60

    Article  CAS  PubMed  Google Scholar 

  • Young GB, Sharpe MD, Savard M, Al Thenayan E, Norton L, Davies-Schinkel C (2009) Seizure detection with a commercially available bedside EEG monitor and the subhairline montage. Neurocrit Care 11:411–6

    Article  PubMed  Google Scholar 

Download references

Acknowledgment

Dr. Rossetti is supported by the Swiss National Science Foundation [Grant CR32I3_143780].

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Vincent Alvarez MD .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer-Verlag Wien

About this chapter

Cite this chapter

Alvarez, V., Rossetti, A.O. (2015). Electroencephalography and Evoked Potentials: Technical Background. In: Rossetti, A., Laureys, S. (eds) Clinical Neurophysiology in Disorders of Consciousness. Springer, Vienna. https://doi.org/10.1007/978-3-7091-1634-0_2

Download citation

  • DOI: https://doi.org/10.1007/978-3-7091-1634-0_2

  • Published:

  • Publisher Name: Springer, Vienna

  • Print ISBN: 978-3-7091-1633-3

  • Online ISBN: 978-3-7091-1634-0

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics