Skip to main content

Einstellparameter des Beatmungsgeräts

  • Chapter
  • First Online:
Pocket Guide Beatmung

Zusammenfassung

Die wesentlichen Einstellparameter des Respirators sind die inspiratorische O2-Konzentration, Atemzugvolumen und -minutenvolumen, Atemfrequenz, maximaler Inspirationsdruck bzw. oberes inspiratorisches Druckniveau, positiver endexspiratorischer Druck bzw. unteres exspiratorisches Druckniveau, Atemzeitverhältnis, Inspirationszeit und Exspirationszeit, Inspirationsflow bzw. Gasgeschwindigkeit sowie Triggerart.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 19.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Weiterführende Literatur

  • AWMF. S3-Leitlinie Invasive Beatmung und Einsatz extrakorporaler Verfahren bei akuter respiratorischer Insuffizienz, 1. Aufl., Langversion, Stand 04.12.2017. https://www.awmf.org/uploads/tx_szleitlinien/001-021l_S3_Invasive_Beatmung_2017-12.pdf

  • Acute Respiratory Distress Syndrome Network (2000) Ventilation with lower tidal volumes as compared with traditional volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 342:1301–1308

    Article  Google Scholar 

  • Gilbert-Kawai ET, Mitchell K, Martin D, Carlisle J, Grocott MPW (2014) Permissive hypoxaemia versus normoxaemia for mechanically ventilated critically ill patients. Cochrane Database Syst Rev 2014(5):CD009931. https://doi.org/10.1002/14651858.cd009931.pub2

    Article  PubMed Central  Google Scholar 

  • The National Heart, Lung, and Blood Institute ARDS Clinical Trials Network (2004) Higher versus lower positive end-expiratory pressure in patients with the acute respiratory distress syndrome. N Engl J Med 351:327–336

    Article  Google Scholar 

  • Tobin MJ (2012) Principles and practice of mechanical ventilation, 3. Aufl. McGraw-Hill, New York

    Google Scholar 

Trainingsprogramm

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Reinhard Larsen .

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer-Verlag GmbH Deutschland, ein Teil von Springer Nature

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Larsen, R., Ziegenfuß, T. (2019). Einstellparameter des Beatmungsgeräts. In: Pocket Guide Beatmung. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-59657-9_3

Download citation

  • DOI: https://doi.org/10.1007/978-3-662-59657-9_3

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-662-59656-2

  • Online ISBN: 978-3-662-59657-9

  • eBook Packages: Medicine (German Language)

Publish with us

Policies and ethics