Towards Full-body X-ray Images

  • Christoph Luckner
  • Thomas Mertelmeier
  • Andreas Maier
  • Ludwig Ritschl
Conference paper
Part of the Informatik aktuell book series (INFORMAT)

Zusammenfassung

Digital tomosynthesis is a tomographic imaging technique whose upsurge is mainly caused by breast imaging. However, it might also be useful in orthopedics due to its high in-plane resolution as well as the fact that tomosynthetic slices do not suffer from magnification or distortion, making measurements possible, for example, even without the need of any calibration object. Since the reading time of such a reconstruction is higher compared to conventional 2-D radiographs, a simple parallel projection of the volume can be computed to get an overview of the volume. However, this leads to a rather blurred image impression since all artifacts and inhomogeneities in the reconstructed volume as well as certain anatomical structures which are not necessary for the diagnosis, will end up in the projection. We propose a method which selects the slices to be projected into a smart synthetic X-ray image in a way which is optimal w.r.t to the sharpness of predefined ROIs (e. g. knee, spine or hip). Therefore, two Laplacian-based auto-focus measures are combined with a thin-plate spline yielding a sharp and homogenous image impression within the smart radiograph. It was shown that the auto-focus method is able to select the same slice as have been selected during an expert annotation. Upon visual inspection, it could be determined that the proposed method achieves higher contrast and clearly better visibility of complex bone structures like spine or hip.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Literatur

  1. 1.
    Dobbins JT. Tomosynthesis imaging: at a translational crossroads. Med Phys. 2009;36(6):1956–1967.Google Scholar
  2. 2.
    Lauritsch G, Härer WH. A theoretical framework for filtered backprojection in tomosynthesis. Proc SPIE. 1998;3338(2):1127–1137.Google Scholar
  3. 3.
    Luckner C, et al. Parallel-shift tomosynthesis for orthopedic applications. Proc SPIE. 2018.Google Scholar
  4. 4.
    Sun Y, Duthaler S, Nelson BJ. Autofocusing in computer microscopy: selecting the optimal focus algorithm. Microscope Res Tech. 2004;65(3):139–149.Google Scholar
  5. 5.
    Bookstein FL. Principal warps: thin-plate splines and the decomposition of deformations. IEEE Trans Pattern Anal Mach Intell. 1989;11(6):567–585.Google Scholar
  6. 6.
    Segars WP, et al. Realistic CT simulation using the 4D XCAT phantom. Med Phys. 2008;35(8):3800–3808.Google Scholar

Copyright information

© Springer-Verlag GmbH Deutschland 2018

Authors and Affiliations

  • Christoph Luckner
    • 1
    • 2
  • Thomas Mertelmeier
    • 2
  • Andreas Maier
    • 1
  • Ludwig Ritschl
    • 2
  1. 1.Pattern Recognition LabFAU Erlangen-NuernbergErlangenDeutschland
  2. 2.Siemens Healthcare GmbHForchheimDeutschland

Personalised recommendations